background image

English

4

Indoor Unit Installation Diagram

CAUTION

• Do not hit or violently push the INTELLIGENT EYE sensor. This can lead to damage and malfunction.

• Do not place large objects near the INTELLIGENT EYE sensor. Also keep heating units or humidifiers outside the sensor’s 

detection area.

1-3/16” (30mm) or more 

from ceiling

Panel 

support plate

Front panel

Intelligent eye sensor

Screw M4 × 5/8” (M4 × 16mm)*

*The 18/24 class models have 5 screws.

SSID sticker with release paper 
(attached to the unit)

P

1-15/16” (50mm) 

or more from walls 

(on both sides)

Titanium apatite 

deodorizing filter (2 pcs.)

C

A

Mounting plate

Mounting plate fixing 

screw M4 × 1” (M4 × 25mm)

B

The      mounting plate 

should be installed on a 

wall which can support the 

weight of the indoor unit.

A

Wrap the insulation pipe 

with the finishing tape from 

bottom to top.

Cut thermal insulation pipe 

to an appropriate length 

and wrap it with tape, 

making sure that no gap is 

left in the insulation pipe’s 

cut line.

Appearance of indoor units 

may differ from some 

models.

(This is a 09/12 class 

illustration)

Do not connect commercially available 

drain hose directly to the indoor unit. 

(Water leakage may result)

Wrap with the finishing tape so that no 

gap is left.

The service lid is removable.

Opening method

1) Remove the service lid 

screw.

2) Pull out the service lid 

horizontally in the 

direction of the arrow.

3) Pull down.

Service lid

Remote controller 

holder fixing screw 

M3 × 13/16” 

(M3 × 20mm)

F

D Wireless 

remote 

controller

E Remote 

controller 

holder

Before screwing the      

remote controller holder to 

the wall, make sure that 

control signals are properly 

received by indoor unit.

E

Screw cover*

*The 18/24 class models 

have 3 screw covers.

J

Air filter

Mounting 

plate

A

Hook

Mark (rear side)

Bottom 

frame

Front grille

M4 × 1/2” 

(M4 × 12mm) 

Titanium apatite 

deodorizing filter

Filter frame

Air filter

Claw

Tab

Caulk pipe hole gap with putty. 

How to attach the indoor unit

Hook the hooks of the bottom frame

to the      mounting plate.

If the hooks are difficult to hook,

remove the front grille.

How to remove the indoor unit

Push up the marked area (at the

lower part of the front grille) to

release the hooks. If it is difficult 

to release, remove the front grille.

A

01_EN_3P686877-1A.fm  4 ページ  2022年6月1日 水曜日 午後12時32分

Summary of Contents for FTXM09WVJU9

Page 1: ...UAL DAIKIN ROOM AIR CONDITIONER R32 Split Series English Fran ais Espa ol MODELS FTXM09WVJU9 FTXM12WVJU9 FTXM18WVJU9 FTXM24WVJU9 Installation manual Manuel d installation Manual de instalaci n 00_CV_3...

Page 2: ...cause serious injury or death Safely dispose all packing and transportation materials in accordance with federal state local laws or ordinances Packing materials such as nails and other metal or wood...

Page 3: ...perty damage Insulate piping to prevent condensation Be careful when transporting the product Do not turn off the power immediately after stopping operation Always wait for at least 5 minutes before t...

Page 4: ...use interference with the picture or sound 10 no laundry equipment is nearby 2 Wireless remote controller Turn on all the fluorescent lamps in the room if any and find a location where the remote cont...

Page 5: ...models This is a 09 12 class illustration Do not connect commercially available drain hose directly to the indoor unit Water leakage may result Wrap with the finishing tape so that no gap is left The...

Page 6: ...liquid pipe end and gas pipe end may differ from the distance between those symbols on the mounting plate the distance listed in this manual Always measure the actual distance between the liquid pipe...

Page 7: ...n tape 3 Pass the drain hose and refrigerant pipes through the wall hole then position the indoor unit on the mounting plate hooks using the markings at the top of the indoor unit as a guide 4 Open th...

Page 8: ...e and drain plug 1 Remove the fixing screw and pull out the drain hose How to switch around the drain plug and drain hose Push the drain plug all the way in using a hexagonal wrench 3 16 inch 4mm Hexa...

Page 9: ...in the corresponding terminals with the screws 5 Connect the ground wires to the corresponding terminals 6 Pull the wires lightly to make sure they are securely connected 7 In case of connecting to an...

Page 10: ...se front end When drain hose requires extension obtain an extension hose with an inner diameter of 5 8 inch 16mm Be sure to thermally insulate the indoor section of the extension hose When connecting...

Page 11: ...ation dimensions as below Use separate thermal insulation pipes for gas and liquid refrigerant pipes Using finishing tape bundle and wrap the indoor unit piping and drain hose together so that the dra...

Page 12: ...hing up pull it toward you Installation method 1 Install the front grille and firmly engage the upper hooks 3 locations 2 Install the 3 screws 1 of the front grille and screw covers 2 pcs 2 1 The 18 2...

Page 13: ...the front grille on page 11 2 Remove electrical wiring box cover 1 screw See Fig 5 6 3 Attach the HA connection code Insert HA connection code to HA connector S21 white Wire HA connection code as sho...

Page 14: ...ircuit breaker to eliminate unnecessary power consumption If the circuit breaker trips to shut off the power to the air conditioner the system will restore the original operation mode when the circuit...

Page 15: ...14 MEMO 01_EN_3P686877 1A fm 14...

Page 16: ...2205 HT M21B545A The two dimensional bar code is a manufacturing code 3P686877 1A 00_CV_3P686877 1A fm 2...

Reviews: