background image

English

2

• Make sure that a separate power supply circuit is provided 

for this unit and that all electrical work is carried out by 
qualified personnel licensed or certified in their jurisdiction 
according to local, state, and national regulations. An 
insufficient power supply capacity or improper electrical 
construction may lead to electric shock or fire.

• Make sure that all wiring is secured, that specified wires are 

used, and that no external forces act on the terminal 
connections or wires. Improper connections or installation 
may result in fire.

• When wiring, position the wires so that the electrical wiring 

box cover can be securely fastened. Improper positioning of 
the electrical wiring box cover may result in electric shock, 
fire, or the terminals overheating.

• Before touching electrical parts, turn off the unit.
• The circuit must be protected with safety devices in 

accordance with local and national codes, i.e. a circuit 
breaker.

• Securely fasten the outdoor unit terminal cover (panel). If 

the terminal cover/panel is not installed properly, dust or 
water may enter the outdoor unit causing fire or electric 
shock.

• When installing or relocating the system, keep the refrigerant 

circuit free from substances other than the specified 
refrigerant (R32) such as air. Any presence of air or other 
foreign substance in the refrigerant circuit can cause an 
abnormal pressure rise or rupture, resulting in injury.

• Do not change the setting of the protection devices. If the 

pressure switch, thermal switch, or other protection device is 
shorted and operated forcibly, or parts other than those 
specified by Daikin are used, fire or explosion may occur.

• When installing or relocating the air conditioner, do not let 

any other substances besides R32, such as air, enter the 
refrigerant circuit. The presence of air or foreign matter in 
the refrigerant circuit causes an abnormal pressure rise, 
which may result in equipment damage and even injury.

• Do not use means to accelerate the defrosting process (if 

possible) or to clean, other than those recommended by the 
manufacturer.

• The appliance must be stored in a room without 

continuously operating ignition sources (for example: open 
flames, an operating gas appliance or an operating electric 
heater).

• Do not pierce or burn.
• Be aware that refrigerants may not contain an odor.
• Comply with national gas regulations.

CAUTION

• Do not touch the switch with wet fingers. Touching a switch 

with wet fingers can cause electric shock.

• Do not allow children to play on or around the unit to prevent 

injury.

• Wear adequate personal protective equipment (protective 

gloves, safety glasses,…) when installing, maintaining or 
servicing the system.

• The heat exchanger fins are sharp enough to cut. To avoid 

injury, wear gloves or cover the fins while working around 
them.

• Do not touch the refrigerant pipes during and immediately 

after operation as the refrigerant pipes may be hot or cold, 
depending on the condition of the refrigerant flowing through 
the refrigerant piping, compressor, and other refrigerant 
cycle parts. Your hands may suffer burns or frostbite if you 
touch the refrigerant pipes. To avoid injury, give the pipes 
time to return to normal temperature or, if you must touch 
them, be sure to wear proper gloves.

• Install drain piping to ensure proper drainage. Improper drain 

piping may result in water leakage and property damage.

• Insulate piping to prevent condensation.
• Be careful when transporting the product.

• Do not turn off the power immediately after stopping 

operation. Always wait for at least 5 minutes before turning 
off the power. Otherwise, water leakage may occur.

• Do not use a charging cylinder. Using a charging cylinder 

may cause the refrigerant to deteriorate.

• Refrigerant R32 in the system must be kept clean, dry, and tight.

(a) Clean and Dry -- Foreign materials (including mineral oils 

such as SUNISO oil or moisture) should be prevented 
from getting into the system.

(b) Tight -- R32 does not contain any chlorine, does not 

destroy the ozone layer, and does not reduce the earth’s 
protection again harmful ultraviolet radiation. R32 can 
contribute to the greenhouse effect if it is released. 
Therefore take proper measures to check for the tightness 
of the refrigerant piping installation. Read the chapter 

Refrigerant Piping Work

 and follow the procedures.

• The indoor unit is for R32. See the catalog for outdoor 

models that can be connected. Normal operation is not 
possible when connected to non-compatible outdoor units.

• Remote controller (wireless kit) transmitting distance can be 

shorter than expected in rooms with electronic fluorescent 
lamps (inverter or rapid start types). Install the indoor unit far 
away from fluorescent lamps as much as possible.

• Indoor units are for indoor installation only. Outdoor units 

can be installed either outdoors or indoors.

• Do not install the air conditioner or heat pump in the 

following locations:
(a) Where a mineral oil mist or oil spray or vapor is produced, 

for example, in a kitchen. 
Plastic parts may deteriorate and fall off or result in water 
leakage.

(b) Where corrosive gas, such as sulfurous acid gas, is 

produced. 
Corroding copper pipes or soldered parts may result in 
refrigerant leakage.

(c) Near machinery emitting electromagnetic waves. 

Electromagnetic waves may disturb the operation of the 
control system and cause the unit to malfunction.

(d) Where flammable gas may leak, where there is carbon fiber, 

or ignitable dust suspension in the air, or where volatile 
flammables such as thinner or gasoline are handled. 
Operating the unit in such conditions can cause a fire.

• Take adequate measures to prevent the outdoor unit from 

being used as a shelter by small animals. Small animals 
making contact with electrical parts can cause malfunctions, 
smoke, or fire. Instruct the user to keep the area around the 
unit clean.

• Servicing shall be performed only as recommended by the 

manufacturer and licensed or certified in their jurisdiction.

NOTE

• The indoor unit should be positioned where the unit and inter-

unit wires (outdoor to indoor) are at least 3.3ft (1m) away from 
any televisions or radios. (The unit may cause interference with 
the picture or sound.) Depending on the radio waves, a distance 
of 3.3ft (1m) may not be sufficient to eliminate the noise.

• Dismantling the unit, treatment of the refrigerant, oil and 

additional parts must be done in accordance with the 
relevant local, state, and national regulations.

• Only use tools for R32 or R410A, such as a gauge manifold, 

charge hose, gas leak detector, reverse flow check valve, 
refrigerant charge base, vacuum gauge, or refrigerant 
recovery equipment.

• If the conventional refrigerant and refrigerator oil are mixed 

in R32, the refrigerant may deteriorate.

• As maximum allowable pressure is 604psi (4.17MPa), the 

wall thickness of field-installed pipes should be selected in 
accordance with the relevant local, state, and national 
regulations.

FTN005(R32)-U

01_EN_3P686877-1A.fm  2 ページ  2022年6月1日 水曜日 午後12時32分

Summary of Contents for FTXM09WVJU9

Page 1: ...UAL DAIKIN ROOM AIR CONDITIONER R32 Split Series English Fran ais Espa ol MODELS FTXM09WVJU9 FTXM12WVJU9 FTXM18WVJU9 FTXM24WVJU9 Installation manual Manuel d installation Manual de instalaci n 00_CV_3...

Page 2: ...cause serious injury or death Safely dispose all packing and transportation materials in accordance with federal state local laws or ordinances Packing materials such as nails and other metal or wood...

Page 3: ...perty damage Insulate piping to prevent condensation Be careful when transporting the product Do not turn off the power immediately after stopping operation Always wait for at least 5 minutes before t...

Page 4: ...use interference with the picture or sound 10 no laundry equipment is nearby 2 Wireless remote controller Turn on all the fluorescent lamps in the room if any and find a location where the remote cont...

Page 5: ...models This is a 09 12 class illustration Do not connect commercially available drain hose directly to the indoor unit Water leakage may result Wrap with the finishing tape so that no gap is left The...

Page 6: ...liquid pipe end and gas pipe end may differ from the distance between those symbols on the mounting plate the distance listed in this manual Always measure the actual distance between the liquid pipe...

Page 7: ...n tape 3 Pass the drain hose and refrigerant pipes through the wall hole then position the indoor unit on the mounting plate hooks using the markings at the top of the indoor unit as a guide 4 Open th...

Page 8: ...e and drain plug 1 Remove the fixing screw and pull out the drain hose How to switch around the drain plug and drain hose Push the drain plug all the way in using a hexagonal wrench 3 16 inch 4mm Hexa...

Page 9: ...in the corresponding terminals with the screws 5 Connect the ground wires to the corresponding terminals 6 Pull the wires lightly to make sure they are securely connected 7 In case of connecting to an...

Page 10: ...se front end When drain hose requires extension obtain an extension hose with an inner diameter of 5 8 inch 16mm Be sure to thermally insulate the indoor section of the extension hose When connecting...

Page 11: ...ation dimensions as below Use separate thermal insulation pipes for gas and liquid refrigerant pipes Using finishing tape bundle and wrap the indoor unit piping and drain hose together so that the dra...

Page 12: ...hing up pull it toward you Installation method 1 Install the front grille and firmly engage the upper hooks 3 locations 2 Install the 3 screws 1 of the front grille and screw covers 2 pcs 2 1 The 18 2...

Page 13: ...the front grille on page 11 2 Remove electrical wiring box cover 1 screw See Fig 5 6 3 Attach the HA connection code Insert HA connection code to HA connector S21 white Wire HA connection code as sho...

Page 14: ...ircuit breaker to eliminate unnecessary power consumption If the circuit breaker trips to shut off the power to the air conditioner the system will restore the original operation mode when the circuit...

Page 15: ...14 MEMO 01_EN_3P686877 1A fm 14...

Page 16: ...2205 HT M21B545A The two dimensional bar code is a manufacturing code 3P686877 1A 00_CV_3P686877 1A fm 2...

Reviews: