background image

English

11

Installation Tips

1.

Removing and installing the front panel

Removal method

1) Place your fingers in the indentations on the main unit (one each on the left and right sides), and open the front panel 

until it stops.

2) While pushing the left side front panel shaft outward, push up the 

front panel and remove it.
(Remove the right side front panel shaft in the same manner.)

3) After removing both front panel shafts, pull the front panel toward 

yourself and remove it.

Installation method

Align the front panel shaft of the front panel with the grooves of grille, and push all the way in, then close slowly. 
Push the center of the lower panel surface firmly to engage the tabs.

2.

Removing and installing the front grille

Removal method 

1) Remove the front panel and air filters.
2) Remove the lower flap. (See 

Fig.1

)

(Do not remove the upper flap.)

3) Remove screw covers (2 pcs.)*. (See 

Fig.2

)

*The 18/24 class models have 3 screw covers.

4) Remove the front grille fixing screws (3 screws)*. (See 

Fig.2

)

*The 18/24 class models have 5 screws.

5) Remove the service lid screws (1 screw) and remove service lid. 

(See 

Fig.3

)

 

6) In front of the 

 mark on the front grille, there are 3 upper 

hooks. Lightly pull the front grille toward you with one hand, 
and push down on the hooks with the fingers of your other 
hand. (See 

Fig.4

)

When there is insufficient work space because the 
unit is close to ceiling

Place both hands under the center of the front grille, and while pushing up, pull it toward 
you.

Installation method

1) Install the front grille and firmly engage the upper hooks (3 locations).

2) Install the 3 screws*

1

 of the front grille and screw covers (2 pcs.)*

2

.

*1 The 18/24 class models have 5 screws.
*2 The 18/24 class models have 3 screw covers.

3) Install the service lid and screw for fixing the service lid (1 screw).
4) Install the air filters and then mount the front panel.

3.

How to set the different addresses

When 2 indoor units are installed in one room, the 2 wireless remote controllers can be set for different addresses. Change the 
address setting of one of the 2 units. When cutting the jumper, be careful not to damage any of the surrounding parts. 

Push the front panel 

shaft of the front panel

into the groove.

Front panel 

shaft

One each on the 

left and right sides

Lower flap

Long flat plate 

wrapped in a cloth

Screw cover

Upper flap

Fig.1

Fig.2

Fig.4

Fig.3

Screw M4 × 1/2” 

(M4 × 12mm) 

Service 

lid

•  Be sure to wear 

protection gloves.

CAUTION

1) Push up.

2) Pull toward 

you.

1) Remove the battery cover on the remote controller and cut the address jumper (J4).

2) Press         ,         and             at the same time.

3) Press         , select    , press            .

(The indoor unit OPERATION lamp will blink for about 1 minute.)

4) Press the indoor unit ON/OFF switch while the OPERATION lamp is blinking.

• If setting could not be carried out completely while the OPERATION lamp 

was blinking, carry out the setting process once again from the beginning.

• After setting is complete, pressing              for about 5 seconds will cause

the remote controller to return to the previous display.

Indoor unit 

ON/OFF switch

Jumper (J4) 

Address

1

EXIST

Jumper J4

2

CUT

01_EN_3P686877-1A.fm  11 ページ  2022年6月1日 水曜日 午後12時32分

Summary of Contents for FTXM09WVJU9

Page 1: ...UAL DAIKIN ROOM AIR CONDITIONER R32 Split Series English Fran ais Espa ol MODELS FTXM09WVJU9 FTXM12WVJU9 FTXM18WVJU9 FTXM24WVJU9 Installation manual Manuel d installation Manual de instalaci n 00_CV_3...

Page 2: ...cause serious injury or death Safely dispose all packing and transportation materials in accordance with federal state local laws or ordinances Packing materials such as nails and other metal or wood...

Page 3: ...perty damage Insulate piping to prevent condensation Be careful when transporting the product Do not turn off the power immediately after stopping operation Always wait for at least 5 minutes before t...

Page 4: ...use interference with the picture or sound 10 no laundry equipment is nearby 2 Wireless remote controller Turn on all the fluorescent lamps in the room if any and find a location where the remote cont...

Page 5: ...models This is a 09 12 class illustration Do not connect commercially available drain hose directly to the indoor unit Water leakage may result Wrap with the finishing tape so that no gap is left The...

Page 6: ...liquid pipe end and gas pipe end may differ from the distance between those symbols on the mounting plate the distance listed in this manual Always measure the actual distance between the liquid pipe...

Page 7: ...n tape 3 Pass the drain hose and refrigerant pipes through the wall hole then position the indoor unit on the mounting plate hooks using the markings at the top of the indoor unit as a guide 4 Open th...

Page 8: ...e and drain plug 1 Remove the fixing screw and pull out the drain hose How to switch around the drain plug and drain hose Push the drain plug all the way in using a hexagonal wrench 3 16 inch 4mm Hexa...

Page 9: ...in the corresponding terminals with the screws 5 Connect the ground wires to the corresponding terminals 6 Pull the wires lightly to make sure they are securely connected 7 In case of connecting to an...

Page 10: ...se front end When drain hose requires extension obtain an extension hose with an inner diameter of 5 8 inch 16mm Be sure to thermally insulate the indoor section of the extension hose When connecting...

Page 11: ...ation dimensions as below Use separate thermal insulation pipes for gas and liquid refrigerant pipes Using finishing tape bundle and wrap the indoor unit piping and drain hose together so that the dra...

Page 12: ...hing up pull it toward you Installation method 1 Install the front grille and firmly engage the upper hooks 3 locations 2 Install the 3 screws 1 of the front grille and screw covers 2 pcs 2 1 The 18 2...

Page 13: ...the front grille on page 11 2 Remove electrical wiring box cover 1 screw See Fig 5 6 3 Attach the HA connection code Insert HA connection code to HA connector S21 white Wire HA connection code as sho...

Page 14: ...ircuit breaker to eliminate unnecessary power consumption If the circuit breaker trips to shut off the power to the air conditioner the system will restore the original operation mode when the circuit...

Page 15: ...14 MEMO 01_EN_3P686877 1A fm 14...

Page 16: ...2205 HT M21B545A The two dimensional bar code is a manufacturing code 3P686877 1A 00_CV_3P686877 1A fm 2...