background image

English

3

Accessories 

Choosing an Installation Site

• Before choosing the installation site, obtain user approval.

1.

Indoor unit

• The indoor unit should be positioned in a place where:

1) the restrictions on the installation requirements specified in 

“Indoor Unit Installation Diagram”

 on page 4 are met,

2) both the air inlet and air outlet are unobstructed,
3) the unit is not exposed to direct sunlight,
4) Install so that drainage occurs easily,
5) the unit is away from sources of heat or steam,
6) there is no source of machine oil vapor (this may shorten the indoor unit service life),
7) cool/warm air is circulated throughout the room,
8) the unit is away from electronic ignition type fluorescent lamps (inverter or rapid start type) as they may affect the remote 

controller range,

9) the unit is at least 3.3ft (1m) away from any television or radio set (the unit may cause interference with the picture or 

sound),

10) no laundry equipment is nearby.

2.

Wireless remote controller

• Turn on all the fluorescent lamps in the room, if any, and find a location where the remote controller signals are properly 

received by the indoor unit (within 23ft (7m)).

Mounting plate 

1

Mounting plate 
fixing screw 
M4 × 1” 
(M4 × 25mm) 

7

Titanium apatite deodorizing 
filter 

2

Wireless remote 
controller  

1

Remote controller 
holder 

1

Remote controller 
holder 
fixing screw 
M3 × 13/16” 
(M3 × 20mm) 

2

Dry battery AAA. 
LR03 (alkaline)

2

Indoor unit fixing 
screw 
M4 × 1/2” 
(M4 × 12mm) 

2

Screw cover 

2

*1

Insulation tape 

1

Operation manual 

1

Installation 
manual 

1

General safety 
considerations 

1

SSID sticker with 
release paper  
(attached to the unit) 

1

Warranty 

1

*1 The 18/24 class models have 3 screw covers.

A

B

C

D

E

F

G

H

J

K

L

M

N

Attach the sticker to the sticker 

attachment area on the cover page 

of the operation manual and keep 

it safe.

*2 The installer should inform the user that it is not necessary to 

attach the QR code portion of the SSID sticker.

*

2

P

Q

01_EN_3P686877-1A.fm  3 ページ  2022年6月1日 水曜日 午後12時32分

Summary of Contents for FTXM09WVJU9

Page 1: ...UAL DAIKIN ROOM AIR CONDITIONER R32 Split Series English Fran ais Espa ol MODELS FTXM09WVJU9 FTXM12WVJU9 FTXM18WVJU9 FTXM24WVJU9 Installation manual Manuel d installation Manual de instalaci n 00_CV_3...

Page 2: ...cause serious injury or death Safely dispose all packing and transportation materials in accordance with federal state local laws or ordinances Packing materials such as nails and other metal or wood...

Page 3: ...perty damage Insulate piping to prevent condensation Be careful when transporting the product Do not turn off the power immediately after stopping operation Always wait for at least 5 minutes before t...

Page 4: ...use interference with the picture or sound 10 no laundry equipment is nearby 2 Wireless remote controller Turn on all the fluorescent lamps in the room if any and find a location where the remote cont...

Page 5: ...models This is a 09 12 class illustration Do not connect commercially available drain hose directly to the indoor unit Water leakage may result Wrap with the finishing tape so that no gap is left The...

Page 6: ...liquid pipe end and gas pipe end may differ from the distance between those symbols on the mounting plate the distance listed in this manual Always measure the actual distance between the liquid pipe...

Page 7: ...n tape 3 Pass the drain hose and refrigerant pipes through the wall hole then position the indoor unit on the mounting plate hooks using the markings at the top of the indoor unit as a guide 4 Open th...

Page 8: ...e and drain plug 1 Remove the fixing screw and pull out the drain hose How to switch around the drain plug and drain hose Push the drain plug all the way in using a hexagonal wrench 3 16 inch 4mm Hexa...

Page 9: ...in the corresponding terminals with the screws 5 Connect the ground wires to the corresponding terminals 6 Pull the wires lightly to make sure they are securely connected 7 In case of connecting to an...

Page 10: ...se front end When drain hose requires extension obtain an extension hose with an inner diameter of 5 8 inch 16mm Be sure to thermally insulate the indoor section of the extension hose When connecting...

Page 11: ...ation dimensions as below Use separate thermal insulation pipes for gas and liquid refrigerant pipes Using finishing tape bundle and wrap the indoor unit piping and drain hose together so that the dra...

Page 12: ...hing up pull it toward you Installation method 1 Install the front grille and firmly engage the upper hooks 3 locations 2 Install the 3 screws 1 of the front grille and screw covers 2 pcs 2 1 The 18 2...

Page 13: ...the front grille on page 11 2 Remove electrical wiring box cover 1 screw See Fig 5 6 3 Attach the HA connection code Insert HA connection code to HA connector S21 white Wire HA connection code as sho...

Page 14: ...ircuit breaker to eliminate unnecessary power consumption If the circuit breaker trips to shut off the power to the air conditioner the system will restore the original operation mode when the circuit...

Page 15: ...14 MEMO 01_EN_3P686877 1A fm 14...

Page 16: ...2205 HT M21B545A The two dimensional bar code is a manufacturing code 3P686877 1A 00_CV_3P686877 1A fm 2...