6 Installation
Installer reference guide
12
FTXA25~50(A)(B)2V1B(W)(S)(T)(B)
Daikin room air conditioner
4P518023-3F – 2019.10
3
Re-install the flap.
4
Insert the wire harness back into the connector and secure it
with the wire clamp.
5
Close the front panel. Refer to
10].
6.2.7
To remove the electrical wiring box cover
1
Remove the front grille.
2
Remove 1 screw from the electrical wiring box.
3
Open the electrical wiring box cover by pulling it to the front.
4
Remove the electrical wiring box cover from the 2 rear hooks.
1
2
b
a
c
c
a
Screw
b
Electrical wiring box
c
Rear hook
5
To re-install the cover, first attach the electrical wiring box to the
hooks, close the electrical wiring box, and re-install the screw.
NOTICE
When closing the electrical wiring box cover, make sure
that
the
tightening
torque
does
NOT
exceed
2.0 (±0.2) N•m.
6.3
Installing the indoor unit
6.3.1
Precautions when installing the indoor
unit
INFORMATION
Also read the precautions and requirements in the
following chapters:
▪ General safety precautions
▪ Preparation
6.3.2
To install the mounting plate
1
Install the mounting plate temporarily.
2
Level the mounting plate.
3
Mark the centres of the drilling points on the wall using a tape
measure. Position the end of tape measure at symbol " ".
4
Finish the installation by securing the mounting plate on the wall
using M4×25L screws (field supply).
INFORMATION
The removed pipe port cover can be kept in the mounting
plate pocket.
44.5
605
17
110
798
150
155
44.5
± 450 mm
± 440 mm
± 400 mm
Ø65
Ø65
f
j
i
d
k
l
m
a
g
f
a
h
h
b
e
c
a
a
a
a
a
a
a
Recommended mounting plate fixing spots
b
Pocket for the pipe port cover
c
Liquid pipe end
d
Gas pipe end