Main Functions
Functions and Control
22
1.3
Airflow Direction Control
Power-Airflow
(Dual) Flap (s)
The large flap sends a large volume of air downward to the floor and provides an optimum control in
cooling, dry, and heating operation.
Cooling/Dry
During cooling or dry operation, the flap retracts into the indoor unit. Then, cool air can be blown far
and distributed all over the room.
Heating
During heating operation, the large flap directs airflow downward to spread the warm air to the
entire room.
Wide-Angle
Louvers
The louvers, made of elastic synthetic resin, provide a wide range of airflow that guarantees
comfortable air distribution.
Auto-Swing
The following tables explain the auto-swing process for cooling, dry, heating, and fan:
FTX Series
FVXS Series
Flap (up and down)
Cooling/Dry
Heating
Fan
09/12 class
15 class
Flap (up and down)
Cooling/Dry
Heating
Upward
airflow limit
OFF
(R6831)
(R6829)
Upward
airflow limit
ON
(R6832)
(R6830)
(R21048)
5˚
50˚
(R21049)
15˚
65˚
(R21050)
0˚
65˚
(R21651)
15˚
30˚
55˚
70˚
(R21652)
80˚
65˚
20˚
35˚
(R21653)
25˚
80˚
10˚
65˚
25˚
90˚
40˚
90˚
20˚
90˚
90˚
20˚
Summary of Contents for FTX09NMVJU
Page 12: ...SiUS091601E 1 List of Functions Part 1 List of Functions 1 Functions 2...
Page 15: ...SiUS091601E Specifications 4 Part 2 Specifications 1 Specifications 5...
Page 65: ...SiUS091601E Remote Controller 54 Part 5 Remote Controller 1 FTX Series 55 2 FVXS Series 57...
Page 144: ...Revision History Month Year Version Revised contents 02 2016 SiUS091601E First edition...