Indoor Unit
SiUS091601E
15
Printed Circuit Board Connector Wiring Diagram
Sensor PCB
(PCB1)
Service PCB
(PCB3)
Display PCB
(PCB4)
LED3 does not function.
Note:
The symbols in the parenthesis are the names on the appropriate wiring diagram.
1) S49
Connector for control PCB
2) RTH2 (R1T)
Room temperature thermistor
S49
RTH2
3P191450-1
1) S27
Connector for control PCB
2) SW2 (S2W)-4
Switch for upward airflow limit setting
∗
Refer to page 121 for detail.
∗
Keep the other switches as factory setting.
3) SW4 (S4W)
Switch for airflow selection
∗
Refer to page 23 for detail.
S27
SW4
SW2-4
3P191448-1
1) S47
Connector for control PCB
2) SW1 (S1W)
Forced cooling operation
ON/OFF
button
3) LED1 (H1P)
LED for operation (green)
4) LED2 (H2P)
LED for timer (yellow)
S47
SW1
LED2
LED1
3P191447-1