FTX-N/U, FVXS-N, FDMQ-R Series EDUS091558E
93
C: 3P379970-7B
1
Safety Considerations
Contents
Safety Considerations .................................... 1
Accessories ..................................................... 3
Choosing an Installation Site ........................ 3
1. Indoor unit ................................................................... 3
2. Wireless remote controller ........................................... 3
Indoor Unit Installation Diagram ................... 4
Indoor Unit Installation ................................... 5
1. Refrigerant piping ........................................................ 5
2. Drilling a wall hole and installing wall embedded
pipe .............................................................................. 7
3. Drain piping ................................................................. 7
4. Installing indoor unit .................................................... 8
4-1. Preparation .......................................................... 8
4-2. Installation ........................................................... 9
5. Flaring the pipe end ..................................................... 12
6. Connecting the refrigerant pipe ................................... 12
6-1. Caution on piping handling .................................. 13
6-2. Selection of copper and heat insulation
materials .............................................................. 13
7. Checking for gas leakage ............................................ 13
8. Attaching the connection pipe ..................................... 13
9. Wiring .......................................................................... 14
10.When connecting to an HA system ............................. 15
11.How to set the different addresses .............................. 16
Trial Operation and Testing ............................ 17
1. Trial operation and testing ........................................... 17
2. Test items .................................................................... 17
Read these
Safety Considerations for Installation
carefully
before installing an air conditioner or heat pump. After completing
the installation, make sure that the unit operates properly during
the startup operation.
Instruct the user on how to operate and maintain the unit.
Inform users that they should store this installation manual with
the operation manual for future reference.
Always use a licensed installer or contractor to install this product.
Improper installation can result in water or refrigerant leakage,
electric shock, fire, or explosion.
Meanings of
DANGER
,
WARNING
,
CAUTION
, and
NOTE
Symbols:
DANGER ...........
Indicates an imminently hazardous
situation which, if not avoided, will
result in death or serious injury.
WARNING .........
Indicates a potentially hazardous
situation which, if not avoided, could
result in death or serious injury.
CAUTION ..........
Indicates a potentially hazardous
situation which, if not avoided, may
result in minor or moderate injury.
It may also be used to alert against
unsafe practices.
NOTE ................
Indicates situations that may result
in equipment or property-damage
accidents only.
DANGER
• Refrigerant gas is heavier than air and replaces oxygen.
A massive leak can lead to oxygen depletion, especially
in basements, and an asphyxiation hazard could occur
leading to serious injury or death.
•
Do not ground units to water pipes, gas pipes, telephone
wires, or lightning rods as incomplete grounding can cause
a severe shock hazard resulting in severe injury or death.
Additionally, grounding to gas pipes could cause a gas leak
and potential explosion causing severe injury or death.
•
If refrigerant gas leaks during installation, ventilate the
area immediately. Refrigerant gas may produce toxic gas
if it comes into contact with fire. Exposure to this gas could
cause severe injury or death.
•
After completing the installation work, check that the
refrigerant gas does not leak throughout the system.
• Do not install unit in an area where flammable materials
are present due to risk of explosions that can cause
serious injury or death.
•
Safely dispose all packing and transportation materials
in accordance with federal/state/local laws or ordinances.
Packing materials such as nails and other metal or
wood parts, including plastic packing materials used for
transportation may cause injuries or death by suffocation.
WARNING
• Only qualified personnel must carry out the installation
work. Installation must be done in accordance with this
installation manual. Improper installation may result in
water leakage, electric shock, or fire.
•
When installing the unit in a small room, take measures
to keep the refrigerant concentration from exceeding
allowable safety limits. Excessive refrigerant leaks, in the
event of an accident in a closed ambient space, can lead
to oxygen deficiency.
• Use only specified accessories and parts for installation
work. Failure to use specified parts may result in water
leakage, electric shock, fire, or the unit falling.
•
Install the air conditioner or heat pump on a foundation
strong enough that it can withstand the weight of the unit.
A foundation of insufficient strength may result in the unit
falling and causing injuries.
•
Take into account strong winds, typhoons, or earthquakes
when installing. Improper installation may result in the unit
falling and causing accidents.
01_EN_3P379970-7B.indd 1
11/12/2015 13:29:40
12.3 FVXS09/12/15NVJU
Summary of Contents for FTX-N/U
Page 1: ...Heat Pump Split Type Air Conditioners FTX N U FVXS N FDMQ R Series EDUS091558E...
Page 2: ......
Page 17: ...FTX N U FVXS N FDMQ R Series EDUS091558E 15 C 3D123383 FTX24UVJU C 3D123379 FTX18UVJU...
Page 19: ...FTX N U FVXS N FDMQ R Series EDUS091558E 17 3D112919B FDMQ18 24RVJU 3D112918B FDMQ12RVJU...
Page 20: ...18 FTX N U FVXS N FDMQ R Series EDUS091558E 3D049611A BRC082A43 C 3D091305A BRC1E73...
Page 22: ...20 FTX N U FVXS N FDMQ R Series EDUS091558E 3D107983A RXL24UMVJUA 3D123362 RXL18UMVJUA...
Page 25: ...FTX N U FVXS N FDMQ R Series EDUS091558E 23 3D112629A FDMQ12 18 24RVJU...
Page 32: ...30 FTX N U FVXS N FDMQ R Series EDUS091558E 3D107985A RXL24UMVJUA...
Page 59: ...FTX N U FVXS N FDMQ R Series EDUS091558E 57 3D113126 FDMQ18RVJU...
Page 60: ...58 FTX N U FVXS N FDMQ R Series EDUS091558E 3D113128 FDMQ24RVJU...
Page 62: ...60 FTX N U FVXS N FDMQ R Series EDUS091558E 3D113129 FDMQ24RVJU...
Page 65: ...FTX N U FVXS N FDMQ R Series EDUS091558E 63 3D123455 FTX18UVJU 3D100354 FTX15NMVJU...
Page 66: ...64 FTX N U FVXS N FDMQ R Series EDUS091558E 3D094737 FVXS09NVJU 3D074866A FTX24UVJU...
Page 67: ...FTX N U FVXS N FDMQ R Series EDUS091558E 65 3D094777A FVXS15NVJU 3D094766 FVXS12NVJU...
Page 70: ...68 FTX N U FVXS N FDMQ R Series EDUS091558E 3D123453 RXL18UMVJUA 3D100636 RXL15QMVJUA...
Page 71: ...FTX N U FVXS N FDMQ R Series EDUS091558E 69 3D123454 RXL24UMVJUA...
Page 394: ...392 FTX N U FVXS N FDMQ R Series EDUS091558E 1P124687 1A...
Page 395: ...FTX N U FVXS N FDMQ R Series EDUS091558E 393 1P124687 1A...
Page 396: ...394 FTX N U FVXS N FDMQ R Series EDUS091558E 1P124687 1A...
Page 397: ...FTX N U FVXS N FDMQ R Series EDUS091558E 395 1P124687 1A...
Page 401: ...FTX N U FVXS N FDMQ R Series EDUS091558E 399 3P124623 1E 4 Fig 6 Fig 5 Fig 8 Fig 7...
Page 412: ...410 FTX N U FVXS N FDMQ R Series EDUS091558E 3P124623 1E 15...
Page 422: ...420 FTX N U FVXS N FDMQ R Series EDUS091558E 3P124623 1E 25 Fig 9 Fig 12 Fig 10 Fig 11...
Page 423: ...FTX N U FVXS N FDMQ R Series EDUS091558E 421 3P124623 1E 26 Fig 14 Fig 13 Fig 16 Fig 15...
Page 425: ...FTX N U FVXS N FDMQ R Series EDUS091558E 423 1P126474 1B...
Page 426: ...424 FTX N U FVXS N FDMQ R Series EDUS091558E 1P126474 1B...
Page 427: ...FTX N U FVXS N FDMQ R Series EDUS091558E 425 1P126474 1B...
Page 428: ...426 FTX N U FVXS N FDMQ R Series EDUS091558E 1P126474 1B...
Page 433: ...FTX N U FVXS N FDMQ R Series EDUS091558E 431 3P162015 1A...
Page 434: ...432 FTX N U FVXS N FDMQ R Series EDUS091558E 3P162015 1A...
Page 435: ...FTX N U FVXS N FDMQ R Series EDUS091558E 433 3P162015 1A...
Page 436: ...434 FTX N U FVXS N FDMQ R Series EDUS091558E 3P162015 1A...
Page 455: ...FTX N U FVXS N FDMQ R Series EDUS091558E 453 3P400464 1...
Page 457: ...FTX N U FVXS N FDMQ R Series EDUS091558E 455 3P561172 1...
Page 459: ...FTX N U FVXS N FDMQ R Series EDUS091558E 457 3P534932 1B...
Page 469: ...FTX N U FVXS N FDMQ R Series EDUS091558E 467 3P436077 1...
Page 471: ...FTX N U FVXS N FDMQ R Series EDUS091558E 469 3P436078 1...
Page 472: ...470 FTX N U FVXS N FDMQ R Series EDUS091558E 3P436079 1 14 26 KPS067A44 Snow Hood Outlet...
Page 473: ...FTX N U FVXS N FDMQ R Series EDUS091558E 471 3P436079 1...
Page 475: ...FTX N U FVXS N FDMQ R Series EDUS091558E 473 3P436071 1...
Page 477: ...FTX N U FVXS N FDMQ R Series EDUS091558E 475 3P436072 1...
Page 478: ...476 FTX N U FVXS N FDMQ R Series EDUS091558E 3P436073 1 14 29 KPS063A47 Snow Hood Outlet...
Page 479: ...FTX N U FVXS N FDMQ R Series EDUS091558E 477 3P436073 1...
Page 480: ...478 FTX N U FVXS N FDMQ R Series EDUS091558E...
Page 481: ......
Page 482: ......
Page 483: ......