FTX-N/U, FVXS-N, FDMQ-R Series EDUS091558E
253
C: 3P379751-5D
3
Read Before Operation
Safety Considerations
Read these
Safety Considerations for Operations
carefully
before operating an air conditioner or heat pump.
Make sure that the unit operates properly during the startup
operation. Instruct the user on how to operate and maintain
the unit.
Inform users that they should store this operation manual
with the installation manual for future reference.
Meanings of
DANGER
,
WARNING
,
CAUTION
, and
NOTE
Symbols:
DANGER �����������
Indicates an imminently hazardous
situation which, if not avoided, will
result in death or serious injury.
WARNING ���������
Indicates a potentially hazardous
situation which, if not avoided,
could result in death or serious
injury.
CAUTION ����������
Indicates a potentially hazardous
situation which, if not avoided, may
result in minor or moderate injury.
It may also be used to alert against
unsafe practices.
NOTE ����������������
Indicates situations that may result
in equipment or property-damage
accidents only.
DANGER
• Do not install the unit in an area where flammable
materials are present due to risk of explosion resulting in
serious injury or death.
• Any abnormalities in the operation of the air conditioner
or heat pump, such as smoke or fire, could result in
severe injury or death. Turn off the power and contact
your dealer immediately.
• Refrigerant gas may produce toxic gas if it comes into
contact with fire, such as from a fan heater, stove, or
cooking device. Exposure to this gas could cause severe
injury or death.
• For refrigerant leakage, consult your dealer.
Refrigerant gas is heavier than air and replaces oxygen.
A massive leak could lead to oxygen depletion, especially
in basements, and an asphyxiation hazard could occur
leading to serious injury or death.
• If equipment utilizing a burner is used in the same room
as the air conditioner or heat pump, there is the danger
of oxygen deficiency which could lead to an asphyxiation
hazard resulting in serious injury or death. Be sure to
ventilate the room sufficiently to avoid this hazard.
• Safely dispose of the packing materials. Packing
materials, such as nails and other metal or wooden parts,
may cause stabs or other injuries.
• Tear apart and throw away plastic packaging bags so
that children will not play with them. Children playing with
plastic bags face the danger of death by suffocation.
WARNING
• Contact your dealer for repair and maintenance.
Improper repair and maintenance may result in water
leakage, electric shock, and fire. Only use accessories
made by Daikin that are specifically designed for use with
the equipment and have them installed by a professional.
• Contact your dealer to move and reinstall the air
conditioner or heat pump. Incomplete installation may
result in water leakage, electric shock, and fire.
• Never let the indoor unit or the remote controller get wet.
Water can cause an electric shock or a fire.
• Never use flammable spray such as hair spray, lacquer,
or paint near the unit. Flammable spray may cause a fire.
• When a fuse blows out, never replace it with one of
incorrect ampere ratings or different wires. Always replace
any blown fuse with a fuse of the same specification.
• Never remove the fan guard of the unit. A fan rotating at
high speed without the fan guard is very dangerous.
• Never inspect or service the unit by yourself. Contact a
qualified service person to perform this work.
• Turn off all electrical power before doing any maintenance
to avoid the risk of serious electric shock; never sprinkle
or spill water or liquids on the unit.
• Do not touch the switch with wet fingers. Touching a
switch with wet fingers can cause electric shock.
• Do not allow children to play on or around the unit to
prevent injury.
• The heat exchanger fins are sharp enough to cut. To avoid
injury wear gloves or cover the fins while working around them.
• Do not put a finger or other objects into the air inlet or air
outlet. The fan is rotating at high speed and will cause injury.
• Check the unit foundation for damage on a continuous
basis, especially if it has been in use for a long time. If left
in a damaged condition the unit may fall and cause injury.
• Placing a flower vase or other containers with water or
other liquids on the unit could cause a shock or fire if a
spill occurs.
• Do not touch the air outlet or horizontal blades while
the swing flap is in operation because fingers could get
caught and injured.
• Never touch the internal parts of the controller. Do not
remove the front panel because some parts inside are
dangerous to touch. To check and adjust internal parts,
contact your dealer.
CAUTION
• Do not use the air conditioner or heat pump for any other
purposes other than comfort cooling or heating.
Do not use the unit for cooling precision instruments,
food, plants, animals or works of art.
01_EN_3P379751-5D.indd 3
11/13/2018 2:16:54 PM
13.3 FVXS09/12/15NVJU
Summary of Contents for FTX-N/U
Page 1: ...Heat Pump Split Type Air Conditioners FTX N U FVXS N FDMQ R Series EDUS091558E...
Page 2: ......
Page 17: ...FTX N U FVXS N FDMQ R Series EDUS091558E 15 C 3D123383 FTX24UVJU C 3D123379 FTX18UVJU...
Page 19: ...FTX N U FVXS N FDMQ R Series EDUS091558E 17 3D112919B FDMQ18 24RVJU 3D112918B FDMQ12RVJU...
Page 20: ...18 FTX N U FVXS N FDMQ R Series EDUS091558E 3D049611A BRC082A43 C 3D091305A BRC1E73...
Page 22: ...20 FTX N U FVXS N FDMQ R Series EDUS091558E 3D107983A RXL24UMVJUA 3D123362 RXL18UMVJUA...
Page 25: ...FTX N U FVXS N FDMQ R Series EDUS091558E 23 3D112629A FDMQ12 18 24RVJU...
Page 32: ...30 FTX N U FVXS N FDMQ R Series EDUS091558E 3D107985A RXL24UMVJUA...
Page 59: ...FTX N U FVXS N FDMQ R Series EDUS091558E 57 3D113126 FDMQ18RVJU...
Page 60: ...58 FTX N U FVXS N FDMQ R Series EDUS091558E 3D113128 FDMQ24RVJU...
Page 62: ...60 FTX N U FVXS N FDMQ R Series EDUS091558E 3D113129 FDMQ24RVJU...
Page 65: ...FTX N U FVXS N FDMQ R Series EDUS091558E 63 3D123455 FTX18UVJU 3D100354 FTX15NMVJU...
Page 66: ...64 FTX N U FVXS N FDMQ R Series EDUS091558E 3D094737 FVXS09NVJU 3D074866A FTX24UVJU...
Page 67: ...FTX N U FVXS N FDMQ R Series EDUS091558E 65 3D094777A FVXS15NVJU 3D094766 FVXS12NVJU...
Page 70: ...68 FTX N U FVXS N FDMQ R Series EDUS091558E 3D123453 RXL18UMVJUA 3D100636 RXL15QMVJUA...
Page 71: ...FTX N U FVXS N FDMQ R Series EDUS091558E 69 3D123454 RXL24UMVJUA...
Page 394: ...392 FTX N U FVXS N FDMQ R Series EDUS091558E 1P124687 1A...
Page 395: ...FTX N U FVXS N FDMQ R Series EDUS091558E 393 1P124687 1A...
Page 396: ...394 FTX N U FVXS N FDMQ R Series EDUS091558E 1P124687 1A...
Page 397: ...FTX N U FVXS N FDMQ R Series EDUS091558E 395 1P124687 1A...
Page 401: ...FTX N U FVXS N FDMQ R Series EDUS091558E 399 3P124623 1E 4 Fig 6 Fig 5 Fig 8 Fig 7...
Page 412: ...410 FTX N U FVXS N FDMQ R Series EDUS091558E 3P124623 1E 15...
Page 422: ...420 FTX N U FVXS N FDMQ R Series EDUS091558E 3P124623 1E 25 Fig 9 Fig 12 Fig 10 Fig 11...
Page 423: ...FTX N U FVXS N FDMQ R Series EDUS091558E 421 3P124623 1E 26 Fig 14 Fig 13 Fig 16 Fig 15...
Page 425: ...FTX N U FVXS N FDMQ R Series EDUS091558E 423 1P126474 1B...
Page 426: ...424 FTX N U FVXS N FDMQ R Series EDUS091558E 1P126474 1B...
Page 427: ...FTX N U FVXS N FDMQ R Series EDUS091558E 425 1P126474 1B...
Page 428: ...426 FTX N U FVXS N FDMQ R Series EDUS091558E 1P126474 1B...
Page 433: ...FTX N U FVXS N FDMQ R Series EDUS091558E 431 3P162015 1A...
Page 434: ...432 FTX N U FVXS N FDMQ R Series EDUS091558E 3P162015 1A...
Page 435: ...FTX N U FVXS N FDMQ R Series EDUS091558E 433 3P162015 1A...
Page 436: ...434 FTX N U FVXS N FDMQ R Series EDUS091558E 3P162015 1A...
Page 455: ...FTX N U FVXS N FDMQ R Series EDUS091558E 453 3P400464 1...
Page 457: ...FTX N U FVXS N FDMQ R Series EDUS091558E 455 3P561172 1...
Page 459: ...FTX N U FVXS N FDMQ R Series EDUS091558E 457 3P534932 1B...
Page 469: ...FTX N U FVXS N FDMQ R Series EDUS091558E 467 3P436077 1...
Page 471: ...FTX N U FVXS N FDMQ R Series EDUS091558E 469 3P436078 1...
Page 472: ...470 FTX N U FVXS N FDMQ R Series EDUS091558E 3P436079 1 14 26 KPS067A44 Snow Hood Outlet...
Page 473: ...FTX N U FVXS N FDMQ R Series EDUS091558E 471 3P436079 1...
Page 475: ...FTX N U FVXS N FDMQ R Series EDUS091558E 473 3P436071 1...
Page 477: ...FTX N U FVXS N FDMQ R Series EDUS091558E 475 3P436072 1...
Page 478: ...476 FTX N U FVXS N FDMQ R Series EDUS091558E 3P436073 1 14 29 KPS063A47 Snow Hood Outlet...
Page 479: ...FTX N U FVXS N FDMQ R Series EDUS091558E 477 3P436073 1...
Page 480: ...478 FTX N U FVXS N FDMQ R Series EDUS091558E...
Page 481: ......
Page 482: ......
Page 483: ......