SiMT041509E
Service Diagnosis
Service Diagnosis
50
3. Service Diagnosis
Method 1
1. When the timer cancel button is held down for 5 seconds,
00
is displayed on the temperature
display screen.
2. Press the timer cancel button repeatedly until a long beep sounds.
The code indication changes in the sequence shown below.
Note:
1. A short beep or two consecutive beeps indicate non-corresponding codes.
2. To return to the normal mode, hold the timer cancel button down for 5 seconds. When the
remote controller is left untouched for 60 seconds, it also returns to the normal mode.
3. Not all the error codes are displayed. When you cannot find the error code, try method 2.
(
→
Refer to page 51.)
(R21282)
< ARC466 Series >
Timer cancel button
No.
Code
No.
Code
No.
Code
1
00
14
U0
27
UA
2
A5
15
C7
28
UH
3
E7
16
A3
29
P4
4
F3
17
H8
30
H7
5
F6
18
H9
31
U2
6
L3
19
C9
32
EA
7
L4
20
C4
33
AH
8
L5
21
C5
34
FA
9
U4
22
J3
35
H1
10
E6
23
J6
36
P9
11
H6
24
E5
37
E3
12
H0
25
A1
38
H3
13
A6
26
E1
Summary of Contents for FTKM18PVMK
Page 16: ...SiMT041509E 1 List of Functions Part 1 List of Functions 1 Functions 2 ...
Page 18: ...SiMT041509E 3 Specifications Part 2 Specifications 1 Specifications 4 ...
Page 59: ...SiMT041509E Remote Controller 44 Part 5 Remote Controller 1 Remote Controller 45 ...
Page 118: ...Revision History Month Year Version Revised contents 07 2015 SiMT041509E First edition ...