SiMT041509E
Main Functions
Function and Control
20
1.8
NIGHT SET Mode
Outline
When the OFF TIMER is set, NIGHT SET Mode is automatically activated. NIGHT SET Mode
keeps the airflow rate setting.
Detail
NIGHT SET Mode continues operation at the target temperature for the first one hour, then
automatically raises the target temperature slightly in the case of cooling, or lowers it slightly in
the case of heating. This prevents excessive cooling in summer and excessive heating in winter
to ensure comfortable sleeping conditions, and also conserves electricity.
<Cooling>
<Heating>
1.9
ECONO Operation
Outline
ECONO operation reduces the maximum power consumption. This operation is particularly
convenient for energy-saving. It is also a major bonus when breaker capacity does not allow the
use of multiple electrical devices and air conditioners.
It can be easily activated by pushing the
ECONO
button on the wireless remote controller.
Detail
When this function is activated, the maximum capacity also decreases.
The remote controller can send the ECONO command when the unit is in cooling, heating,
dry, or automatic operation. This function can only be set when the unit is running. Press the
ON/OFF
button on the remote controller to cancel the function.
This function and POWERFUL operation cannot be used at the same time. The latest
command has the priority.
(R22018)
TIMER operation
NIGHT SET Mode ON
Target temperature
+0.5˚C
temperature shift
Operation stops
at the set hours
0.5˚C
1 hour
TIMER operation
NIGHT SET Mode ON
Target temperature
–2˚C
temperature shift
1 hour
2˚C
(R22029)
ECONO operation
(R21051)
Normal operation
Maximum during normal operation
Maximum during ECONO operation
Time
Power
consumption
Summary of Contents for FTKM18PVMK
Page 16: ...SiMT041509E 1 List of Functions Part 1 List of Functions 1 Functions 2 ...
Page 18: ...SiMT041509E 3 Specifications Part 2 Specifications 1 Specifications 4 ...
Page 59: ...SiMT041509E Remote Controller 44 Part 5 Remote Controller 1 Remote Controller 45 ...
Page 118: ...Revision History Month Year Version Revised contents 07 2015 SiMT041509E First edition ...