![background image](http://html1.mh-extra.com/html/daikin/fte09mv2s/fte09mv2s_service-manual_2459325021.webp)
Si041138
Removal of Drain Pan Unit / Swing Motor
Removal Procedure
19
7. Removal of Drain Pan Unit / Swing Motor
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1. Remove the drain pan
unit.
Preparation
Remove the electrical box
according to the “Removal of
Electrical Box.”
Inserting of the wooden base
facilitates the removing
work.
Place a plastic sheet under
the drain pan to prevent from
wetting the floor with
remaining drain.
1
Lift up the indoor unit
slightly and pull out the
drain hose. (In the case
of left piping)
2
Remove the screw at
the right side of the
drain pan unit.
3
Press the right side of
the drain pan unit and
twist the left side.
Drain hose
Wooden base
(R4374)
(R4375)
Drain pan unit
Keep
pressing
here
Twist here
(R12547)