TGL/DGL Installation Instructions

General

These instructions are intended as general guidelines. The air conditioner must be installed by trained and authorized personnel.

Use the following size copper tubing for connecting the outdoor and indoor units:
Models TGL/DGL 9, 11 - 3/8" and 1/4". Models TGL/DGL 15, 20, 25 - 1/4" and 1/2". Models TGL 30 - 3/8" and 5/8".

Installation must be performed in accordance with the manufacturer’s specifications, using only approved tubing, original electrical
cables and accessories.

Standard Accessories

Electrical Requirements

The air conditioner must be directly connected to an
appropriate power source.

Use 16A fuses for all Models TGL/DGL air conditioners.

Use a single-length power cable, without extensions.

When installing a Dual System air-conditioner of DGL
series (a single outdoor unit and two separate indoor units)
both indoor units must be connected to the mains power supply in order for the system to function properly.

Indoor and Outdoor Unit Location

The indoor and outdoor units should be installed as
close to each other as possible. Do not exceed the tubing
lengths and height differences which appear in the accompanying
table above:

Outdoor Unit

Make sure to leave sufficient space around the unit. See Figure 1 for
minimum required distances between the unit and nearby walls.

Install the unit in a location with convenient access for service and
maintenance purposes.

Position the unit to minimize motor noise which reaches the customer
and neighbors.

In heating mode, water can form in the condenser. A drainage hose may
be attached to the unit. Use the adapter shown Figure 1.

For opening service door in models TGL 9-20, keep a minimum distance of
0.27m (10" 62') between the unit and the support's end.

Make sure of installing the unit legs to the support.

Indoor Unit

Make sure to leave sufficient space around the unit. See Figure 2 for minimum
required distances between the unit and the ceiling, floor and surrounding walls.

Locate the unit to ensure free air flow around it.

A 120 cm. power cable is supplied with the unit. We recommend placing the power
outlet near the unit, on its right side.

Avoid installing the unit near a
source of heat, such as direct
sunlight, steam or a flame.

Install the unit in a location
with convenient access to
refrigerant line connections
for service and maintenance
purposes.

0.15m   (6") min.

0.2m

(8")

min.

1.8

−2

.5m

(6'-8'3") min.

b

c

a

0.2m

(8")

min.

Fig. 1

Model

Maximum tubing

Maximum height

 length in meters (ft)

difference between unit

 in meters (ft)

TGL-9, 11, 15, 20, 25, 30

15 (49')

10 (33')

DGL-9, 11, 15, 20

15 (49')

10 (33')

DGL-11/15

15 (49')

10 (33')

Outdoor

Model

Dimensions

TGL 9-20

TGL 25-30

mm (")

DGL ALL

Plastic Model

a

320 

(32.3")

265 

(45.3")

b

641 

(12.6")

540 

(13.8")

c

1100 

(6.7")

730 

(7.9")

Fig. 2

Indoor

Model

Dimensions

TGL 9-20

TGL 25-30

mm (")

a

185 

(32.3")

185 

(45.3")

b

260 

(12.6")

295

 (13.8")

c

815 

(6.7")

1080 

(7.9")

Drain hose adapter

for

≠ 

≠ 

≠ 

≠ 

≠ 

DGL/TGL 9-20

WIRELESS DIGITAL REMOTE CONTROLLER

WIRELESS DIGITAL REMOTE CONTROLLER

WIRELESS DIGITAL REMOTE CONTROLLER

WIRELESS DIGITAL REMOTE CONTROLLER

S TA R T

S T O P

1     2     3     S L E E P

D A I LY

M O D E

FA N

S W E E P

Drain hose adapter

for

≠ 

≠ 

≠ 

≠ 

≠ 

DGL/TGL 25-30

Remote Controller

and Batteries

Remote Controller Rack

Insulation for Fittings

User's Manual

Wall Plugs

Long Screws

Mounting Bracket

Outdoor sensor

connecting cable

Absorption cushions

for DGL and TGL 25-30

Electrical terminal block

6/7 stations according

to the model

0.6m(2')

min.

0.15m(6")

min.

a

c

0.6m(2')

min.

0.15m(6")

min.

0.6m

(2')

min

.

b

0.6m(2')

0.15m(6")

min.

min.

min.

min.

min.

b

a

c

0.6m(2')

0.6m(2')

0.15m(6")

TGL 9-20

DGL, TGL 25-30

Insert the

drainage adapter

from the inside of

the outdoor unit

Insert the

drainage adapter

from the outside of

the outdoor unit

TGL - 51302613575

50Hz TAC 505 TAC 506 0600

Summary of Contents for TGL-9

Page 1: ... Make sure of installing the unit legs to the support Indoor Unit Make sure to leave sufficient space around the unit See Figure 2 for minimum required distances between the unit and the ceiling floor and surrounding walls Locate the unit to ensure free air flow around it A 120 cm power cable is supplied with the unit We recommend placing the power outlet near the unit on its right side Avoid inst...

Page 2: ...properly Fill the pan below the unit s coil with water and observe that freely drains out See Figure 5 Wiring the indoor unit Remove the air conditioner cover by lifting the lower part and then pulling it gently outward See Figure 8 Remove the two screws from the plastic control cover as shown in Figure 9 Route the inter unit electric cable and the outdoor sensor cable towards the lower right corn...

Page 3: ...lock male female in accordance with the color coding which appears in Figure 11 Connect the outdoor sensor cable TH3 making sure the connector is properly inserted Secure the inter unit electric cable to the outdoor unit with the clamp shown in Figure 10a Reassemble the plastic side cover Notes A drainage tube can be connected to the outdoor unit to remove condensation formed during heating mode o...

Page 4: ...e stem cap Oil the cap beam and hands tighten the cap until resistance is met Use a suitable wrench to tighten the cap by an additional 1 6 turn Check the system for refrigerant leakage using a leak detector Finishing the job Hide the tubing where possible Make sure that the drainage tube slopes downwards along its entire length Insulate tubing connections with the insulation supplied Fasten tubes...

Reviews: