Removal of Electrical Box
Si041138
12
Removal Procedure
5
Disconnect the
connector for the fan
motor [S7].
6
Remove the screw and
remove the drip proof
plate.
7
Pull out the indoor heat
exchanger thermistor.
Be careful not to lose the clip
for the thermistor.
8
Remove the screw and
detach the earth wire.
Step
Procedure
Points
(R11470)
[S7]
Drip proof plate
(R12721)
Indoor heat
exchanger
thermistor
(R12722)
Clip
(R11234)
Earth wire
(R4345)