background image

 

FHYCP + FCQ
Split System air conditioners
4PW23696-1

Installation manual

9

W

IRING

 

DIAGRAM

33H ......................FLOAT SWITCH

A1P......................PRINTED CIRCUIT BOARD

C1R .....................CAPACITOR (FAN MOTOR)

CD .......................CURRENT DETECT CIRCUIT

F1U......................FUSE (250 V/5 A) (only for FCQ35~60)

HAP,HBP .............LIGHT EMITTING DIODE (SERVICE MONITOR -

GREEN)

M1A .....................MOTOR (SWING FLAP)

M2F .....................MOTOR (INDOOR FAN)

M3P .....................MOTOR (DRAIN PUMP)

PC........................PHASE CONTROL CIRCUIT

Q1F......................THERMO SWITCH (M2F EMBEDDED)

R1T......................THERMISTOR (AIR)

R2T......................THERMISTOR (LIQUID)

R3T......................THERMISTOR (COIL) (only for FCQ35~60)

RC .......................SIGNAL RECEIVER CIRCUIT

RyC......................MAGNETIC RELAY (OUTDOOR UNIT

COMPRESSOR)

RyP......................MAGNETIC RELAY (DRAIN PUMP)

SS1......................SELECTOR SWITCH (EMERGENCY)

T1R......................TRANSFORMER (230 V, 22 V)

TC........................SIGNAL TRANMISSION CIRCUIT

X1M,X2M.............TERMINAL STRIP

WIRED REMOTE CONTROLLER

SS1 ..................... SELECTOR SWITCH (MAIN/SUB)

RECEIVER/DISPLAY UNIT (ATTACHED TO WIRELESS REMOTE
CONTROLLER)

A2P,A3P .............. PRINTED CIRCUIT BOARD

BS ....................... ON/OFF BUTTON

H1P ..................... LIGHT EMITTING DIODE (ON - RED)

H2P ..................... LIGHT EMITTING DIODE (TIMER - GREEN)

H3P ..................... LIGHT EMITTING DIODE (FILTER SIGN - RED)

H4P ..................... LIGHT EMITTING DIODE (DEFROST - ORANGE)

SS1 ..................... SELECTOR SWITCH (MAIN/SUB)

SS2 ..................... SELECTOR SWITCH (WIRELESS ADDRESS

SET)

ADAPTER FOR WIRING

RyC,RyF ............. MAGNETIC RELAY

CONNECTOR FOR OPTIONAL PARTS

X30A ................... CONNECTOR (INTERFACE ADAPTOR FOR

SKY AIR SERIES) (only for FHYCP)

X33A ................... CONNECTOR (ADAPTOR FOR WIRING)

X35A ................... CONNECTOR (GROUP CONTROL ADAPTOR)

X40A ................... CONNECTOR (REMOTE ON/OFF, FORCED

OFF)

X60A,X61A ......... CONNECTOR (INTERFACE ADAPTOR FOR

SKY AIR SERIES) (only for FCQ)

: FIELD WIRING

BLK

: BLACK

: TERMINAL

RED

: RED

: CONNECTOR

WHT

: WHITE

: WIRE CLAMP

YLW

: YELLOW

: PROTECTIVE EARTH (SCREW)

,

RECEIVER/DISPLAY UNIT

:

IN CASE OF SIMULTANEOUS OPERATION SYSTEM

:

MASTER

:

SLAVE

:

REMOTE CONTROLLER

:

WIRED REMOTE CONTROLLER

:

ADAPTOR FOR WIRING

:

TERMINALS FOR OPERATION INDICATOR

:

FAN OPERATION

:

COMPRESSOR OPERATION

:

SWITCH BOX

:

NOTE

1.

WHEN USING THE CENTRAL REMOTE CONTROLLER, SEE MANUAL FOR CONNECTION TO UNIT.

2.

X24A IS CONNECTED WHEN THE WIRELESS REMOTE CONTROLLER KIT IS USED.

3.

THE REMOTE CONTROLLER MODEL VARIES ACCORDING TO THE COMBINATION SYSTEM. SEE TECHNICAL MATERIALS
AND CATALOGS, ETC. BEFORE CONNECTING.

Summary of Contents for FHYCP100B8V1

Page 1: ...INSTALLATION MANUAL FHYCP71B8V1 FHYCP100B8V1 FHYCP125B8V1 FCQ35B8V1 FCQ50B8V1 FCQ60B8V1 FCQ71B8V3B FCQ100B8V3B FCQ125B8V3B Split System air conditioners...

Page 2: ...4 2 7 8 9 10 12 13 11 1 2 3 1500 1500 2 3 4 5 1 50 100 1 2 3 4 950 1 1 5 35 35 3 7 1 4 3 5 5 75 550 750 220 300 mm 1 1 5 mm 1 2 3 4 5 6 100 mm 1 2 2 1 1 4 4 3 3 1 2 1 3 2 1 7 6 1 2 3 4 5 6 7 8 9 10 11...

Page 3: ...1 2 3 P1 P2 6 P1 P2 1 2 3 1 2 3 1 2 3 4 5 P1 P2 6 1 2 3 1 2 3 1 2 3 4 5 P1 P2 1 2 3 1 2 3 1 2 3 4 5 P1 P2 P1 P2 1 2 3 1 2 3 1 2 3 4 5 P1 P2 P1 P2 P1 P2 6 6 1 2 3 1 2 3 1 2 3 4 7 8 P1 P2 1 2 3 P1 P2 1...

Page 4: ...jumiem atbilst sekojo iem standartiem un citiem normat viem dokumentiem 24 s v zhode s nasledovnou mi normou ami alebo in m i normat vnym i dokumentom ami za predpokladu e sa pou vaj v s lade s na im...

Page 5: ...r or gasoline is used Where machines generating electromagnetic waves exist Control system may malfunction Where the air contains high levels of salt such as air near the ocean and where voltage fluct...

Page 6: ...ions Select the air flow directions best suited to the room and point of installation For air discharge in 2 or 3 directions it is necessary to make field settings by means of the remote controller an...

Page 7: ...t and washer from the upper and lower sides of the hanger bracket Securing the hanger bracket See figure 6 2 Fix the paper pattern for installation For new ceilings only The paper pattern for installa...

Page 8: ...g pipe vinyl pipe of 25 mm nominal diameter and 32 mm outer diameter Insert the supplied drain hose into the drain socket up to the white tape Tighten the clamp until the screw head is less then 4mm f...

Page 9: ...he outdoor unit the capacity of the circuit breaker and switch and wiring instructions Electrical characteristics Specifications for field wire WIRING EXAMPLE AND HOW TO SET THE REMOTE CONTROLLER How...

Page 10: ...worst case electric shock or fire WIRING EXAMPLE For the wiring of outdoor units refer to the installation manual attached to the outdoor units Confirm the system type Pair type or multi system 1 remo...

Page 11: ...ual setting on page 7 to set master and slave units separately When using wireless remote controllers When using wireless remote controllers wireless remote controller address setting is necessary Ref...

Page 12: ...e for 3 minutes 6 Push air flow direction adjust button to make sure the unit is in operation 7 Press Inspection Test Operation button and operate normally 8 Confirm function of unit according to the...

Page 13: ...IODE TIMER GREEN H3P LIGHT EMITTING DIODE FILTER SIGN RED H4P LIGHT EMITTING DIODE DEFROST ORANGE SS1 SELECTOR SWITCH MAIN SUB SS2 SELECTOR SWITCH WIRELESS ADDRESS SET ADAPTER FOR WIRING RyC RyF MAGNE...

Page 14: ...Zandvoordestraat 300 B 8400 Oostende Belgium 4PW23696 1...