• Indoor Units • R-410A • FBQ-C7VEB

• Split Sky Air • Indoor Units

12

7

Wiring diagram

7 - 1 Wiring diagram

2TW31276-1A

NOTES

1

Use copper conductors only.

2

When using the central remote controller, see manual for connection to the unit.

3

The remote control model varies according to the combination system.
See technical materials and catalogues, etc. before connecting.

4

Refer to installation manual.

Indoor unit

M1F

Motor (fan)

SS1

Selector switch (emergency)

 TC

Signal transmission circuit

A1P

Printed circuit board

M1P

Motor (drain pump)

S1L

Float switch

Connector optional accessory

A2P

Printed circuit board (fan)

PS

Switching power supply

V1R

Diode bridge

X28A

Connector (Power supply for wiring)

C1

Capacitor

Q1DI

Earth leak detector

V2R

Power module

X33A

Connector (for wiring)

F1U, F2U

Fuse (T, 5A, 250V)

R1

Resistor (current limiting)

X1M

Terminal strip (power supply)

X35A

Connector (adapter)

F4U

Fuse (T, 6.3A, 250V)

R2

Current sensing device

X2M

Terminal strip (control)

X85A

Connector (for multi zoning)

HAP

Light emitting diode (Service monitor green)

R1T

Thermistor (suction air)

Z1C

Noise filter (ferrite core)

X33A

Connector (for wiring)

KPR, K1R

Magnetic relay

R2T

Thermistor (liquid)

Z1F

Noise filter

Wired remote control

L1R

Reactor

R3T

Thermistor (gas)

 RC

Signal receiver circuit

SS1

Selector switch (emergency)

1N~220-240V 50Hz
1N~220V 60Hz

indoor

Common 

power supply

note 4

Transmission 
wiring central 
remote control
note 2

wired remote control
(optional accessory)

Switch box (indoor)

norm.emg

Colors
BLK

: Black

BLU

: Blue

BRN

: Brown

GRY

: Gray

ORG

: Orange

PNK

: Pink

RED

: Red

WHT

: White

YLW

: Yellow

GRN

: Green

: Field wiring

L

: Live

N

: Neutral

: Connector
: Wire clamp
: Protective earth 
(screw)

,

FBQ35-50C7VEB

FBQ60-140C7VEB

2TW31296-1A

NOTES

1

Use copper conductors only.

2

When using the central remote controller, see manual for connection to the unit.

3

The remote control model varies according to the combination system. See technical materials and catalogues, etc. before connecting.

4

Refer to installation manual.

Indoor unit

L1R

Reactor

R3T

Thermistor (gas)

TC

Terminal strip (control)

A1P

Printed circuit board

M1F

Motor (fan)

R5T

Thermistor NTC (Current limiting)

Y1E

Electronic expansion valve

A2P

Printed circuit board (fan)

M1P

Motor (drain pump)

SS1

Selector switch (emergency)

Connector optional accessory

A3P

Printed circuit board (capacitor)

PS

Switching power supply

S1L

Float switch

X33A

Connector (for wiring)

C1, C2, C3

Capacitor

Q1DI

Earth leak detector

V1R

Diode bridge

X35A

Connector (adapter)

F1U

Fuse (T, 5A, 250V)

R2

Current sensing device

V2R

Power module

X38A

Connector (for wiring)

F3U

Fuse (T, 6.3A, 250V)

R3, R4

Resistor (electric discharge)

Z1C

Noise filter (ferrite core)

Wired remote control

HAP

Light emitting diode (service monitor green)

R1T

Thermistor (suction air)

Z1F

Noise filter

R1T

Thermistor (air)

KPR, K1R

Magnetic relay

R2T

Thermistor (liquid)

 RC

Terminal strip (power supply)

SS1

Selector switch (main/sub)

1N~220-240V 50Hz
1N~220V 60Hz

only for 

60 class

Common 

power supply

note 4

Transmission 

wiring central 

remote control
note 2

Wired remote control
(optional accessory)

Switch box (indoor)

NORM

.

EMG

only for 

60 class

Colors
BLK

: Black

BLU

: Blue

BRN

: Brown

GRY

: Gray

ORG

: Orange

PNK

: Pink

RED

: Red

WHT

: White

YLW

: Yellow

GRN

: Green

: Field wiring

L

: Live

N

: Neutral

: Connector
: Wire clamp
: Protective earth 
(screw)

,

Summary of Contents for FBQ-C

Page 1: ...FBQ C C o n c e a l e d C e i l i n g U n i t Air Conditioners Technical Data E E D E N 1 0 1 0 0...

Page 2: ...FBQ C C o n c e a l e d C e i l i n g U n i t Air Conditioners Technical Data E E D E N 1 0 1 0 0...

Page 3: ...3 Safety device settings 5 4 Options 5 5 Dimensional drawing centre of gravity 7 Dimensional drawing 7 Centre of gravity 10 6 Piping diagram 11 7 Wiring diagram 12 Wiring diagram 12 8 Sound data 13 So...

Page 4: ...air volume Blends unobtrusively with any interior d cor only the suction and discharge grilles are visible Energy efficient up to class A energy labels Home leave operation saves energy during absenc...

Page 5: ...tages 16 16 16 16 16 16 16 Tube type Hi XSS 7 Fin Type Symmetric waffle louvre Treatment Hydrophilic Fan Type Sirocco fan Quantity 1 1 2 2 3 3 3 Air Flow Rate Cooling High m min 16 16 18 18 32 39 39 L...

Page 6: ...rain pump fuse Notes Nominal cooling capacities are based on indoor temperature 27 CDB 19 CWB outdoor temperature 35 CDB equivalent refrigerant piping 7 5m level difference 0m Nominal heating capaciti...

Page 7: ...panel on the unit Contents of accessory bag Item FBQ35 50 FBQ60 71 FBQ100 125 140 Panel related Decoration panel 4 BYBS45D BYBS71D BYBS125D Air inlet and air discharge outlet related Air discharge ada...

Page 8: ...hite connect to indoor PCB X30A On Off On Off On Off On Off unit INPUT Operating method Wire specifications Forced off On off operation Input on stops operation disables control Input off on starts op...

Page 9: ...r filter it is necessary to provide a service access panel Refer to the filter installation method drawing Fresh air intake position Knock out hole On circumference FBQ50C 3TW31214 1A NOTE 1 Refer to...

Page 10: ...e View A A Detail B Suspension bolt Service space Detail B 350 or more Service space Suspension position Suspension position or more FBQ71C 3TW31234 1A NOTE 1 Refer to outlook drawing for installing o...

Page 11: ...y to provide a service access panel Refer to the filter installation method drawing View A A Detail B Suspension bolt Service space Detail B 350 or more Service space Suspension position 631 Suspensio...

Page 12: ...or Units R 410A FBQ C7VEB Split Sky Air Indoor Units 10 5 Dimensional drawing centre of gravity 5 2 Centre of gravity FBQ35 140C 4TW31189 1B Model A B FBQ35 50 283 700 FBQ60 71 441 1000 FBQ100 140 619...

Page 13: ...275 1 Heat exchanger Liquid pipe connection port Gas pipe connection port Refrigerant flow Cooling Heating Refrigerant pipe connection port diameters Model Gas Liquid FBQ35C 9 52 6 35 FBQ50C 12 70 6 3...

Page 14: ...NK Pink RED Red WHT White YLW Yellow GRN Green Field wiring L Live N Neutral Connector Wire clamp Protective earth screw FBQ35 50C7VEB FBQ60 140C7VEB 2TW31296 1A NOTES 1 Use copper conductors only 2 W...

Page 15: ...microphone Sound pressure level dB FBQ60C Octave band center frequency Hz High tap Medium tap Low tap Unit Microphone Discharge Suction FBQ71C 3TW31297 2 Notes 1 Data is valid at free field condition...

Page 16: ...of microphine Sound pressure level dB Octave band center frequency dB 1 5m Microphone Unit 2m 2m 1 5m 1m High tap Medium tap Low tap Discharge Suction FBQ140C 3TW31337 2 Notes 1 Data is valid at free...

Page 17: ...c intensity 0dB 10E 6 W m2 3 Measured according to ISO 3744 Sound power level dB FBQ60C Octave band center frequency Hz High tap Medium tap Low tap FBQ71C 3TW31297 1 Notes 1 dBA A weighted sound power...

Page 18: ...2 Sound power spectrum FBQ125 140C 3TW31267 1 Notes 1 dBA A weighted sound power level A scale according to IEC 2 Reference acoustic intensity 0dB 10E 6 W m2 3 Measured according to ISO 3744 Sound pr...

Page 19: ...ESP M max ESP H max ESP L std ESP H std ESP M std ESP NOTES 1 Fan characteristics as shown are in fan only mode 2 ESP External static pressure FBQ60C 3TW31298 1 Fan characteristics 1 Fan characteristi...

Page 20: ...ESP by airflow auto adjustment Lower limit of ESP External static pressure Pa External static pressure Pa H M L External static pressure Pa FBQ100C 3TW31258 1 Fan characteristics 1 Fan characteristic...

Page 21: ...ax ESP M max ESP H max ESP L std ESP H std ESP M std ESP NOTES 1 Fan characteristics as shown are in fan only mode 2 ESP External static pressure FBQ125C 3TW31268 1 Fan characteristics 1 Fan character...

Page 22: ...ng return Installation with duct Direct installation of inlet panel Wide variety of installation methods Easy modification from rear to bottom suction Drain pump up height Number Description 1 Main bo...

Page 23: ...with air inlet duct or less NOTES Nr Description 1 When installing the unit with rear suction a service opening is necessary for the maintenance of the air filters 2 When installing the unit with a su...

Page 24: ...Indoor Units R 410A FBQ C7VEB Split Sky Air Indoor Units 22 10 Installation 10 3 Switch box connection FXSQ35 140C 3TW31184 5A Emerg Common power supply Norm FBQ...

Page 25: ...n and development of a wide range of products and an energy management system resulting in energy conservation and a reduction of waste Daikin Europe N V is participating in the EUROVENT Certification...

Reviews: