background image

• Split Sky Air • Indoor Units

5

• Indoor Units • R-410A • FBQ-C7VEB

3

Safety device settings

4

Options

Safety devices

35

50

60

71

100

125

140

FBQ

PC Board Fuse

250V  3.15A

250V  3.15A

250V  3.15A

250V  3.15A

250V  3.15A

250V  3.15A

250V  3.15A

PC Board Fuse (Fan Driver)

250V  5A

250V  5A

250V  6.3A

250V  6.3A

250V  6.3A

250V  6.3A

250V  6.3A

Fan Motor Thermal Protector

°C

Drain Pump Fuse

°C

145

145

145

145

145

145

145

FBQ35-140C

3TW31279-3D

Options

Operation Control

(*1): Electrical heater and humidifier are field supply. These parts should not be installed inside the equipment (refer to installation manual EKRP1B2A)
(*2): If installing an electrical heater, an option PCB for external electrical heater (EKRP1B2) for each indoor unit is required.
(*3): Mounting plate KRP4A96 is required for these options. Maximum 2 option PCB’s can be mounted.
(*4): Decoration panel option EKBYBSD is required for direct mounting of the decoration panel on the unit.

Contents of accessory bag

Item

FBQ35,50

FBQ60,71

FBQ100,125,140

Panel related

Decoration panel (*4)

BYBS45D

BYBS71D

BYBS125D

Air inlet and air discharge outlet related

Air discharge adapter for round duct

KDAJ25K56A

KDAJ25K71A

KDAJ25K140A

Panel related

Decoration panel option

EKBYBSD

Item

FBQ35,50

FBQ60,71

FBQ100,125,140

Remote Control

Wired Type

BRC1D528 / BRC1E51A

Wireless Type

HP

BRC4C65

CO

BRC4C66

Option BCB for external el. heater, humidifier and/or hour meter (*1), (*3)

EKRP1B2A

Adapter for wiring (interlock for fresh air intake fan) (*3)

KRP1C64

Wiring adapter for electrical appendices (*3)

KRP4A51

Remote sensor

KRCS01-4B

Central remote control

DCS302CA51

Unified ON/OFF controller

DCS301BA51

Schedule timer

DST301BA51

Remote ON/OFF and FORCED OFF kit

EKRORO3

Mounting plate for adapter PCB

KRP4A96

Description

Quantity

FBQ35,50,60,71,100,125,140

Hexagon tapping screw (M5x16)

16

Round plain washer for wood

8

Installation and operation manual

1

Hose band

1

Insulation for joint (GAS)

1

Insulation for joint (LIQUID)

1

Drain hose

1

Drain hose sealing material

1

Sealing material

2

NOTES

Summary of Contents for FBQ-C

Page 1: ...FBQ C C o n c e a l e d C e i l i n g U n i t Air Conditioners Technical Data E E D E N 1 0 1 0 0...

Page 2: ...FBQ C C o n c e a l e d C e i l i n g U n i t Air Conditioners Technical Data E E D E N 1 0 1 0 0...

Page 3: ...3 Safety device settings 5 4 Options 5 5 Dimensional drawing centre of gravity 7 Dimensional drawing 7 Centre of gravity 10 6 Piping diagram 11 7 Wiring diagram 12 Wiring diagram 12 8 Sound data 13 So...

Page 4: ...air volume Blends unobtrusively with any interior d cor only the suction and discharge grilles are visible Energy efficient up to class A energy labels Home leave operation saves energy during absenc...

Page 5: ...tages 16 16 16 16 16 16 16 Tube type Hi XSS 7 Fin Type Symmetric waffle louvre Treatment Hydrophilic Fan Type Sirocco fan Quantity 1 1 2 2 3 3 3 Air Flow Rate Cooling High m min 16 16 18 18 32 39 39 L...

Page 6: ...rain pump fuse Notes Nominal cooling capacities are based on indoor temperature 27 CDB 19 CWB outdoor temperature 35 CDB equivalent refrigerant piping 7 5m level difference 0m Nominal heating capaciti...

Page 7: ...panel on the unit Contents of accessory bag Item FBQ35 50 FBQ60 71 FBQ100 125 140 Panel related Decoration panel 4 BYBS45D BYBS71D BYBS125D Air inlet and air discharge outlet related Air discharge ada...

Page 8: ...hite connect to indoor PCB X30A On Off On Off On Off On Off unit INPUT Operating method Wire specifications Forced off On off operation Input on stops operation disables control Input off on starts op...

Page 9: ...r filter it is necessary to provide a service access panel Refer to the filter installation method drawing Fresh air intake position Knock out hole On circumference FBQ50C 3TW31214 1A NOTE 1 Refer to...

Page 10: ...e View A A Detail B Suspension bolt Service space Detail B 350 or more Service space Suspension position Suspension position or more FBQ71C 3TW31234 1A NOTE 1 Refer to outlook drawing for installing o...

Page 11: ...y to provide a service access panel Refer to the filter installation method drawing View A A Detail B Suspension bolt Service space Detail B 350 or more Service space Suspension position 631 Suspensio...

Page 12: ...or Units R 410A FBQ C7VEB Split Sky Air Indoor Units 10 5 Dimensional drawing centre of gravity 5 2 Centre of gravity FBQ35 140C 4TW31189 1B Model A B FBQ35 50 283 700 FBQ60 71 441 1000 FBQ100 140 619...

Page 13: ...275 1 Heat exchanger Liquid pipe connection port Gas pipe connection port Refrigerant flow Cooling Heating Refrigerant pipe connection port diameters Model Gas Liquid FBQ35C 9 52 6 35 FBQ50C 12 70 6 3...

Page 14: ...NK Pink RED Red WHT White YLW Yellow GRN Green Field wiring L Live N Neutral Connector Wire clamp Protective earth screw FBQ35 50C7VEB FBQ60 140C7VEB 2TW31296 1A NOTES 1 Use copper conductors only 2 W...

Page 15: ...microphone Sound pressure level dB FBQ60C Octave band center frequency Hz High tap Medium tap Low tap Unit Microphone Discharge Suction FBQ71C 3TW31297 2 Notes 1 Data is valid at free field condition...

Page 16: ...of microphine Sound pressure level dB Octave band center frequency dB 1 5m Microphone Unit 2m 2m 1 5m 1m High tap Medium tap Low tap Discharge Suction FBQ140C 3TW31337 2 Notes 1 Data is valid at free...

Page 17: ...c intensity 0dB 10E 6 W m2 3 Measured according to ISO 3744 Sound power level dB FBQ60C Octave band center frequency Hz High tap Medium tap Low tap FBQ71C 3TW31297 1 Notes 1 dBA A weighted sound power...

Page 18: ...2 Sound power spectrum FBQ125 140C 3TW31267 1 Notes 1 dBA A weighted sound power level A scale according to IEC 2 Reference acoustic intensity 0dB 10E 6 W m2 3 Measured according to ISO 3744 Sound pr...

Page 19: ...ESP M max ESP H max ESP L std ESP H std ESP M std ESP NOTES 1 Fan characteristics as shown are in fan only mode 2 ESP External static pressure FBQ60C 3TW31298 1 Fan characteristics 1 Fan characteristi...

Page 20: ...ESP by airflow auto adjustment Lower limit of ESP External static pressure Pa External static pressure Pa H M L External static pressure Pa FBQ100C 3TW31258 1 Fan characteristics 1 Fan characteristic...

Page 21: ...ax ESP M max ESP H max ESP L std ESP H std ESP M std ESP NOTES 1 Fan characteristics as shown are in fan only mode 2 ESP External static pressure FBQ125C 3TW31268 1 Fan characteristics 1 Fan character...

Page 22: ...ng return Installation with duct Direct installation of inlet panel Wide variety of installation methods Easy modification from rear to bottom suction Drain pump up height Number Description 1 Main bo...

Page 23: ...with air inlet duct or less NOTES Nr Description 1 When installing the unit with rear suction a service opening is necessary for the maintenance of the air filters 2 When installing the unit with a su...

Page 24: ...Indoor Units R 410A FBQ C7VEB Split Sky Air Indoor Units 22 10 Installation 10 3 Switch box connection FXSQ35 140C 3TW31184 5A Emerg Common power supply Norm FBQ...

Page 25: ...n and development of a wide range of products and an energy management system resulting in energy conservation and a reduction of waste Daikin Europe N V is participating in the EUROVENT Certification...

Reviews: