background image

• Split Sky Air • Indoor Units

3

• Indoor Units • R-410A • FBQ-C7VEB

2

Specifications

2-1 For indoor units only

FBQ35C7VEB

FBQ50C7VEB

FBQ60C7VEB

FBQ71C7VEB

FBQ100C7VEB FBQ125C7VEB FBQ140C7VEB

Nominal input (Indoor 
only)

Cooling

kW

0.14

0.14

0.35

0.35

0.35

0.35

0.35

Heating

kW

0.14

0.14

0.35

0.35

0.35

0.35

0.35

2-2 Technical Specifications

FBQ35C7VEB

FBQ50C7VEB

FBQ60C7VEB

FBQ71C7VEB

FBQ100C7VEB FBQ125C7VEB FBQ140C7VEB

Casing

Colour

Non painted

Material

Galvanised steel

Dimensions

Packing

Height

mm

355

355

355

355

355

355

355

Width

mm

920

920

1,220

1,220

1,620

1,620

1,620

Depth

mm

900

900

900

900

900

900

900

Unit

Height

mm

300

300

300

300

300

300

300

Width

mm

700

700

1,000

1,000

1,400

1,400

1,400

Depth

mm

700

700

700

700

700

700

700

Weight

Unit

kg

25

25

34

34

45

45

45

Packed Unit

kg

28

28

41

41

53

53

53

Required Ceiling Void

mm

>350

Heat Exchanger

Dimensions

Length

mm

440

440

740

740

1,140

1,140

1,140

Nr  of  Rows

3

3

3

3

3

3

3

Fin Pitch

mm

1.75

1.75

1.75

1.75

1.75

1.75

1.75

Nr of Passes

4

4

7

7

11

11

11

Face Area

0.148

0.148

0.249

0.249

0.383

0.383

0.383

Nr of Stages

16

16

16

16

16

16

16

Tube type

Hi-XSS (7)

Fin

Type

Symmetric waffle louvre

Treatment

Hydrophilic

Fan

Type

Sirocco fan

Quantity

1

1

2

2

3

3

3

Air  Flow  Rate

Cooling

High

m³/min

16

16

18

18

32

39

39

Low

m³/min

11

11

15

15

23

28

28

Heating

High

m³/min

16

16

18

18

32

39

41

Low

m³/min

11

11

15

15

23

28

29

Fan

Max

High

Pa

100

100

100

100

120

120

120

Standard

Pa

30

30

30

30

40

50

50

Motor

Quantity

1

1

1

1

1

1

1

Model

Brushless DC

Number  of  steps

10

10

8

8

9

9

9

Motor

Speed (cooling)

High

rpm

1,186

1,186

942

942

1,060

1,218

1,218

Low

rpm

875

875

823

823

813

920

920

Speed (heating)

High

rpm

1,186

1,186

942

942

1,060

1,218

1,280

Low

rpm

875

875

823

823

813

920

967

Fan

Motor

Output (high)

W

140

140

350

350

350

350

350

Drive

Direct drive

Cooling

Sound Power

High

dBA

63

63

57

57

61

66

66

Sound Pressure

High

dBA

37

37

37

37

38

40

40

Low

dBA

29

29

29

29

32

33

33

Heating

Sound Pressure

High

dBA

37

37

37

37

38

40

41

Low

dBA

29

29

29

29

32

33

34

Refrigerant

Type

R-410A

Piping connections

Liquid (OD)

Type

Flare connection

Diameter (OD)

mm

6.35

6.35

6.35

9.52

9.52

9.52

9.52

Gas

Type

Flare connection

Diameter (OD)

mm

9.52

12.7

12.7

15.9

15.9

15.9

15.9

Drain

Diameter (OD)

mm

VP25 (O.D. 32 / I.D. 25)

Heat Insulation

Both liquid and gas pipes

Drain-up Height

mm

625

625

625

625

625

625

625

Summary of Contents for FBQ-C

Page 1: ...FBQ C C o n c e a l e d C e i l i n g U n i t Air Conditioners Technical Data E E D E N 1 0 1 0 0...

Page 2: ...FBQ C C o n c e a l e d C e i l i n g U n i t Air Conditioners Technical Data E E D E N 1 0 1 0 0...

Page 3: ...3 Safety device settings 5 4 Options 5 5 Dimensional drawing centre of gravity 7 Dimensional drawing 7 Centre of gravity 10 6 Piping diagram 11 7 Wiring diagram 12 Wiring diagram 12 8 Sound data 13 So...

Page 4: ...air volume Blends unobtrusively with any interior d cor only the suction and discharge grilles are visible Energy efficient up to class A energy labels Home leave operation saves energy during absenc...

Page 5: ...tages 16 16 16 16 16 16 16 Tube type Hi XSS 7 Fin Type Symmetric waffle louvre Treatment Hydrophilic Fan Type Sirocco fan Quantity 1 1 2 2 3 3 3 Air Flow Rate Cooling High m min 16 16 18 18 32 39 39 L...

Page 6: ...rain pump fuse Notes Nominal cooling capacities are based on indoor temperature 27 CDB 19 CWB outdoor temperature 35 CDB equivalent refrigerant piping 7 5m level difference 0m Nominal heating capaciti...

Page 7: ...panel on the unit Contents of accessory bag Item FBQ35 50 FBQ60 71 FBQ100 125 140 Panel related Decoration panel 4 BYBS45D BYBS71D BYBS125D Air inlet and air discharge outlet related Air discharge ada...

Page 8: ...hite connect to indoor PCB X30A On Off On Off On Off On Off unit INPUT Operating method Wire specifications Forced off On off operation Input on stops operation disables control Input off on starts op...

Page 9: ...r filter it is necessary to provide a service access panel Refer to the filter installation method drawing Fresh air intake position Knock out hole On circumference FBQ50C 3TW31214 1A NOTE 1 Refer to...

Page 10: ...e View A A Detail B Suspension bolt Service space Detail B 350 or more Service space Suspension position Suspension position or more FBQ71C 3TW31234 1A NOTE 1 Refer to outlook drawing for installing o...

Page 11: ...y to provide a service access panel Refer to the filter installation method drawing View A A Detail B Suspension bolt Service space Detail B 350 or more Service space Suspension position 631 Suspensio...

Page 12: ...or Units R 410A FBQ C7VEB Split Sky Air Indoor Units 10 5 Dimensional drawing centre of gravity 5 2 Centre of gravity FBQ35 140C 4TW31189 1B Model A B FBQ35 50 283 700 FBQ60 71 441 1000 FBQ100 140 619...

Page 13: ...275 1 Heat exchanger Liquid pipe connection port Gas pipe connection port Refrigerant flow Cooling Heating Refrigerant pipe connection port diameters Model Gas Liquid FBQ35C 9 52 6 35 FBQ50C 12 70 6 3...

Page 14: ...NK Pink RED Red WHT White YLW Yellow GRN Green Field wiring L Live N Neutral Connector Wire clamp Protective earth screw FBQ35 50C7VEB FBQ60 140C7VEB 2TW31296 1A NOTES 1 Use copper conductors only 2 W...

Page 15: ...microphone Sound pressure level dB FBQ60C Octave band center frequency Hz High tap Medium tap Low tap Unit Microphone Discharge Suction FBQ71C 3TW31297 2 Notes 1 Data is valid at free field condition...

Page 16: ...of microphine Sound pressure level dB Octave band center frequency dB 1 5m Microphone Unit 2m 2m 1 5m 1m High tap Medium tap Low tap Discharge Suction FBQ140C 3TW31337 2 Notes 1 Data is valid at free...

Page 17: ...c intensity 0dB 10E 6 W m2 3 Measured according to ISO 3744 Sound power level dB FBQ60C Octave band center frequency Hz High tap Medium tap Low tap FBQ71C 3TW31297 1 Notes 1 dBA A weighted sound power...

Page 18: ...2 Sound power spectrum FBQ125 140C 3TW31267 1 Notes 1 dBA A weighted sound power level A scale according to IEC 2 Reference acoustic intensity 0dB 10E 6 W m2 3 Measured according to ISO 3744 Sound pr...

Page 19: ...ESP M max ESP H max ESP L std ESP H std ESP M std ESP NOTES 1 Fan characteristics as shown are in fan only mode 2 ESP External static pressure FBQ60C 3TW31298 1 Fan characteristics 1 Fan characteristi...

Page 20: ...ESP by airflow auto adjustment Lower limit of ESP External static pressure Pa External static pressure Pa H M L External static pressure Pa FBQ100C 3TW31258 1 Fan characteristics 1 Fan characteristic...

Page 21: ...ax ESP M max ESP H max ESP L std ESP H std ESP M std ESP NOTES 1 Fan characteristics as shown are in fan only mode 2 ESP External static pressure FBQ125C 3TW31268 1 Fan characteristics 1 Fan character...

Page 22: ...ng return Installation with duct Direct installation of inlet panel Wide variety of installation methods Easy modification from rear to bottom suction Drain pump up height Number Description 1 Main bo...

Page 23: ...with air inlet duct or less NOTES Nr Description 1 When installing the unit with rear suction a service opening is necessary for the maintenance of the air filters 2 When installing the unit with a su...

Page 24: ...Indoor Units R 410A FBQ C7VEB Split Sky Air Indoor Units 22 10 Installation 10 3 Switch box connection FXSQ35 140C 3TW31184 5A Emerg Common power supply Norm FBQ...

Page 25: ...n and development of a wide range of products and an energy management system resulting in energy conservation and a reduction of waste Daikin Europe N V is participating in the EUROVENT Certification...

Reviews: