English
6
3. Make a through hole in the wall.
•
Piping can be led out from the left, right or rear sides.
( Refer to Fig. 2 )
•
The drain hole is on the right side.
•
Select the piping route and open a through hole in the wall (
φ
80). Ensure the hole slopes gradually
downward to the outside. Also, make sure the piping trap can be gotten from the exit (the end).
4. Cut an opening in the left or right side panel for
piping. ( Refer to Fig. 3 )
Ex. For right side piping connections
5. Hang the indoor unit securely from the hook on
the installation panel.
(Refer to Fig. 4 and 5)
•
If running pipes from the left side or using embedded pipes, remove the bottom panel to make work
easier.
CAUTION
Install the unit so that it is level or slanted to the right, and so that it is not tilted forward. Slanting to
the left or tilting forward will impede proper water discharge and cause leaking.
Do not hold the horizontal blades when lifting the unit. (This may cause damage to the blades.)
Front side
Fig. 2
Top side
Back side
Piping direction
Cut along
perforrated line.
Cutting possible up to this point.
Fig. 3
Hole where to
hook indoor unit
1) Installation panel
Fig. 5
Fig. 4
Wall
Hook