background image

1

English

CONTENTS

1. SAFETY PRECAUTIONS.............................. 1
2. WHAT TO DO BEFORE OPERATION.......... 4
3. OPERATION RANGE.................................... 5
4. INSTALLATION SITE .................................... 6
5. OPERATION PROCEDURE.......................... 6
6. OPERATION CHARACTERISTICS............... 6
7. OPTIMUM OPERATION................................ 9
8. MAINTENANCE

(FOR SERVICE PERSONNEL)..................... 9

9. NOT A MALFUNCTION OF THE AIR 

CONDITIONER............................................ 11

10. TROUBLE SHOOTING................................ 14
11. DISPOSAL REQUIREMENTS..................... 15

The original instructions are written in English. All 
other languages are translations of the original in-
structions.

Thank you for purchasing this Daikin air conditioner. 
Carefully read this operation manual before using 
the air conditioner. It will tell you how to use the unit 
properly and help you if any trouble occurs. This 
operation manual is dedicated for the indoor unit. 
Also refer to the operation manuals provided with 
the outdoor unit and remote controller.

*Only applicable if this appliance is connected with 
the following models of outdoor units:
RZAG71, RZASG71, RZAG100, RZASG100, 
RZAG140, RZASG140, AZAS71, AZAS100.

This appliance is filled with R32.*

1. SAFETY PRECAUTIONS

To gain full advantage of the air conditioner’s functions and to 
avoid malfunction due to mishandling, please read this 
operation manual carefully before use.
This product comes under the term “appliances not accessible 
to the general public”.

This appliance is intended to be used by expert or trained 

users in shops, in light industry and on farms, or for com-

mercial and household use by lay persons.
This appliance can be used by children aged from 8 years 

and above and persons with reduced physical, sensory or 

mental capabilities or lack of experience and knowledge if 

they have been given supervision or instruction concern-

ing use of the appliance in a safe way and understand the 

hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by chil-

dren without supervision.

The appliance is not intended for use by unattended young 

children or persons who are incompetent to operate air 

conditioners.

It may result in injury or electric shocks.

This manual classifies the precautions into WARNINGS 
and CAUTIONS. Be sure to follow all the precautions 
below:  They are all important for ensuring safety.

WARNING

....... Indicates a potentially hazardous situation 

which, if not avoided, could result in death 
or serious injury.

CAUTION

........ Indicates a potentially hazardous situation 

which, if not avoided, may result in minor 
or moderate injury.  
It may also be used to alert against unsafe 
practices.

(1)

 For refrigerant used please refer to the nameplate 

of the outdoor unit.

(2)

 GWP = global warming potential

 
Periodical inspections for refrigerant leaks may be 
required depending on European or local legislation. 
Please contact your local dealer for more information.

Important information regarding 
the refrigerant used

This product contains fluorinated greenhouse gases. 
Do not vent gases into the atmosphere.

Refrigerant type

(1)

:

GWP

(2)

 value for 

R410A

 is 

2087.5

GWP

(2)

 value for 

R32

 is 

675

R410A or R32

NOTICE 

regarding tCO

2

eq

In Europe, the 

greenhouse gas emissions 

of 

the total 

refrigerant charge in the system 

(expressed as tonnes CO

-equivalent) is used 

to determine the maintenance intervals. Follow 
the applicable legislation.

Formula to calculate the greenhouse gas 
emissions:

GWP value of the refrigerant × Total refrigerant 
charge [in kg] / 1000

4PEN465287-1C.book  Page 1  Thursday, March 23, 2017  2:47 PM

Summary of Contents for FAA71AUVEB

Page 1: ...OPERATION MANUAL FAA71AUVEB FAA100AUVEB Split system air conditioners...

Page 2: ...r lack of experience and knowledge if they have been given supervision or instruction concern ing use of the appliance in a safe way and understand the hazards involved Children shall not play with th...

Page 3: ...the air conditioner after the qual ified service person makes sure to confirm that the leakage is repaired Do not place objects including rods your fingers etc in the air inlet or outlet Injury may r...

Page 4: ...t produce naked flames in places exposed to the airflow from the air conditioner as this may impair combustion of the burner Do not block air inlets nor outlets Impaired airflow may result in insuffic...

Page 5: ...INDOOR 1 1 Cooling only type This system provides COOLING PROGRAM DRY and FAN OPERATION modes PRECAUTIONS FOR GROUP CONTROL SYSTEM OR TWO REMOTE CONTROLLER CONTROL SYSTEM This system provides two othe...

Page 6: ...beyond the fol lowing conditions safety devices may work and the air conditioner may not operate or sometimes water may drop from the indoor unit COOLING C HEATING C DB Dry bulb temperature WB Wet bu...

Page 7: ...rried out properly to ensure complete drainage If drain piping is not carried out properly dirt and debris may be accumulated in the drain pipe and cause water leakage If it occurs stop the air con di...

Page 8: ...hen a combustion appliance is used ventilate the room regularly Do not use the combustion appliance where the air from the air conditioner is blown directly toward it When the warm air stays under the...

Page 9: ...ection for a period of time to prevent conden sation on the air flow flaps When room temperature is higher than the set temperature When the HEAT ING OPERA TION starts or during DEFROST OPERATION if f...

Page 10: ...Cold air gathers on the floor and warm air gathers in the ceiling Set the air discharge to horizontal direction during COOLING or PROGRAM DRY OPERATION and set it downwards during HEATING OPERATION Do...

Page 11: ...R OUTLET EXTERIOR AND REMOTE CONTROLLER Wipe with a soft dry cloth If a stain cannot be removed wipe it with a cloth firmly wringed after soaked in diluted neutral deter gent After that wipe the area...

Page 12: ...s will prevent generation of mould Turn off the power circuit breaker When the power circuit breaker is turned on low wattage is consumed even if the system is not operating Turn off the power circuit...

Page 13: ...RATION during the COOLING OPERATION the airflow rate is low ered to prevent the carryover of melted water After a while the airflow rate can be changed The airflow rate cannot be set for the PRO GRAM...

Page 14: ...DEFROST OPERATION This is the noise of refrigerant caused by flow stop and flow change During HEATING OPERATION the system switches to DEFROST OPERATION automati cally The remote controller shows Aft...

Page 15: ...breaker earth leakage breaker ON OFF If the air filter is clogged Ask a qualified service person to clean the air filters Refer to MAINTENANCE on page 9 A decrease in the airflow volume of the air co...

Page 16: ...he battery contains a heavy metal above a certain concentration Possible chemical symbols are Pb lead 0 004 Do not try to dismantle the system yourself the dismantling of the product treatment of the...

Page 17: ......

Page 18: ...4P465287 1C 2017 03 Copyright 2017 Daikin...