10 About the system
Installation and operation manual
26
EWAQ016~ EWYQ016~064CAW
Packaged air-cooled water chiller
4P489435-1B – 2017.10
K1P
Pump contactor
K1S
Pump overcurrent relay
K*R (A3P)
Printed circuit board relay
M1P
Pump
PS (A*P)
Switching power supply
Q1DI
Earth leakage circuit breaker (field supply)
Q1T
Thermostat for expansion vessel heater
R11T
Leaving water thermistor (PHE1)
R12T
Returning water thermistor (PHE1)
R13T
Refrigerant liquid thermistor (PHE1)
R14T
Refrigerant gas thermistor (PHE1)
R21T
Leaving water thermistor (PHE2)
R22T
Returning water thermistor (PHE2)
R23T
Refrigerant liquid thermistor (PHE2)
R24T
Refrigerant gas thermistor (PHE2)
S1F
Flow switch (PHE1)
S2F
Flow switch (PHE2)
S1M
Main switch
S1S
Thermostat ON/OFF input (field supply)
S2S
Thermostat cooling/heating selection (field
supply)
S3S
Operation ON input (field supply)
S4S
Operation OFF input (field supply)
SS1 (A1P, A5P)
Selector switch (emergency)
SS1 (A2P)
Selector switch (master/slave)
SS1 (A7P)
Selector switch (master/slave) (optional)
V1C, V2C
Ferrite core noise filter
X1M~X4M
Terminal strip
X801M (A*P)
Printed circuit board terminal strip (control)
Z1F, Z2F (A*P)
Noise filter
For the user
10
About the system
NOTICE
For future modifications or expansions of your system:
A full overview of allowable combinations (for future
system extensions) is available in technical engineering
data and should be consulted. Contact your installer to
receive more information and professional advice.
This small inverter chiller can be combined with fan coil units for air
conditioning purposes, or it can be used for supplying water for
process cooling applications.
10.1
System layout
Your small inverter chiller can be one of following models:
Model
Description
EWAQ
Air-to-water cooling only model.
EWYQ
Air-to-water heat pump model.
11
User interface
CAUTION
NEVER touch the internal parts of the controller.
Do NOT remove the front panel. Some parts inside are
dangerous to touch and appliance problems may happen.
For checking and adjusting the internal parts, contact your
dealer.
a
g
h
b
d
f
i
j
k
c
e
a
ON/OFF button
b
Quiet mode button
c
Programming button
d
Weather dependent setpoint button
(heat pump units
only)
e
Schedule timer button
f
Inspection/test operation button
g
The / button is used to select the operation mode:
space heating ( ) or space cooling ( ).
h
button
i
Room temperature adjust buttons
and
j
Leaving water temperature adjust buttons
and
k
Time adjust buttons
and
Icon
Description
Operation LED
Lit during space heating operation. Blinks if a
malfunction occurs. When the LED is off, space
heating is inactive while the other operation modes
can still be active.
Heating mode
Cooling mode
Quiet mode