background image

9 Disposal

Operation manual

20

ET9W

Daikin Altherma 3 H HT F

4P644733-1 – 2021.02

9

Disposal

NOTICE

Do  NOT  try  to  dismantle  the  system  yourself:  dismantling
of  the  system,  treatment  of  the  refrigerant,  oil  and  other
parts  MUST  comply  with  applicable  legislation.  Units
MUST  be  treated  at  a  specialised  treatment  facility  for
reuse, recycling and recovery.

10

Glossary

DHW = Domestic hot water

Hot  water  used,  in  any  type  of  building,  for  domestic
purposes.

LWT = Leaving water temperature

Water temperature at the water outlet of the unit.

11

Installer settings: Tables to be
filled in by installer

11.1

Configuration wizard

Setting

Fill in…

System

Indoor unit type

 (read only)

Backup heater type

 [9.3.1]

(read only)

Domestic hot water

 [9.2.1]

Emergency

 [9.5]

Number of zones

 [4.4]

Glycol Filled system

(overview field setting [E‑0D])

Backup heater

Voltage

 [9.3.2]

Configuration

 [9.3.3]

Capacity step 1

 [9.3.4]

Additional capacity step 2

[9.3.5] (if applicable)

Main zone

Emitter type

 [2.7]

Control

 [2.9]

Setpoint mode

 [2.4]

Schedule

 [2.1]

WD curve type

 [2.E]

Additional zone

 (only if [4.4]=1, dual zone)

Emitter type

 [3.7]

Control

 (read only) [3.9]

Setpoint mode

 [3.4]

Schedule

 [3.1]

WD curve type

 [3.C] (read only)

Tank

Setting

Fill in…

Heat up mode

 [5.6]

Comfort setpoint

 [5.2]

Eco setpoint

 [5.3]

Reheat setpoint

 [5.4]

Setpoint mode

 [5.B]

WD curve type

 [5.E] (read only)

11.2

Settings menu

Setting

Fill in…

Main zone

Thermostat type

 [2.A]

Additional zone

 (if applicable)

Thermostat type

 [3.A]

Information

Dealer information

 [8.3]

Summary of Contents for ETVZ16S23EA6V

Page 1: ...Operation manual Daikin Altherma 3 H HT F English Operation manual Daikin Altherma 3 H HT F ETVZ16S18EA6V ETVZ16S23EA6V ETVZ16S18EA9W ETVZ16S23EA9W...

Page 2: ...installer 20 11 1 Configuration wizard 20 11 2 Settings menu 20 1 About this document Thank you for purchasing this product Please Read the documentation carefully before operating the user interface...

Page 3: ...leaning and user maintenance SHALL NOT be made by children without supervision WARNING To prevent electrical shocks or fire Do NOT rinse the unit Do NOT operate the unit with wet hands Do NOT place an...

Page 4: ...has been repaired WARNING Air purging heat emitters or collectors Before you purge air from heat emitters or collectors check if or is displayed on the home screen of the user interface If not you can...

Page 5: ...vention Even if you turn OFF space heating cooling operation C 2 Operation Space heating cooling water pipe freeze prevention if enabled will remain active 1 Go to C 2 Operation Space heating cooling...

Page 6: ...the temperatures Change the temperature Go to the next temperature Confirm changes and proceed More information For more information see also 5 4 Turning operation ON or OFF 411 5 6 Space heating cool...

Page 7: ...Export the current settings i e field settings MMI EEPROM settings schedule timers from the user interface MMI to the USB memory stick LCD screen The LCD screen has a sleeping function After 15 min o...

Page 8: ...nt 1 5 Setpoint range Heating minimum Heating maximum Cooling minimum Cooling maximum 7 2 Time date Hours Minutes Year Month Day Daylight savings time Format 7 3 Holiday Activation From Till 7 4 Quiet...

Page 9: ...failure and system operates in Emergency mode or heat pump is forced off d Current date and time e Smart energy e1 Smart energy is available via solar panels or smart grid e2 Smart energy is currentl...

Page 10: ...in zone Shows the applicable symbol for your main zone emitter type Set the leaving water temperature for the main zone 3 Additional zone Restriction Only displayed if there are two leaving water temp...

Page 11: ...ng operation ON b Space heating cooling operation OFF Tank heating operation 1 6 bar 55 21 35 45 c 1 6 bar 55 21 35 45 d c Tank heating operation ON d Tank heating operation OFF 5 4 2 To turn ON or OF...

Page 12: ...following options Heating Only heating mode Cooling Only cooling mode Automatic The operation mode changes automatically between heating and cooling based on the outdoor temperature Restricted per mo...

Page 13: ...ed to heat up the water to a preset value example Comfort 60 C During the morning you consume hot water and the DHW tank temperature decreases At 14 00 the DHW tank is programmed to heat up the water...

Page 14: ...ule to the other weekdays 5 Program the schedule for Saturday and copy it to Sunday 6 Give the schedule a name To go to the schedule 1 Go to 1 1 Room Schedule 2 Set scheduling to Yes 3 Go to 1 2 Room...

Page 15: ...and confirm the selected character The schedule name can contain up to 15 characters 5 Confirm the new name INFORMATION Not all schedules can be renamed 5 9 Weather dependent curve 5 9 1 What is a wea...

Page 16: ...and proceed 5 9 3 Slope offset curve Slope and offset Define the weather dependent curve by its slope and offset Change the slope to differently increase or decrease the temperature of the leaving wat...

Page 17: ...one Cooling WD curve Additional zone Heating 3 5 Additional zone Heating WD curve Additional zone Cooling 3 6 Additional zone Cooling WD curve Zone Go to Tank Restriction Only available to installers...

Page 18: ...gerant total refrigerant charge in kg 1000 Please contact your installer for more information WARNING FLAMMABLE MATERIAL The refrigerant inside this unit is mildly flammable WARNING Do NOT pierce or b...

Page 19: ...s the domestic hot water heating and space heating stops To manually recover it via the user interface go to the Malfunctioning main menu screen and confirm whether the backup heater can take over the...

Page 20: ...tting Fill in System Indoor unit type read only Backup heater type 9 3 1 read only Domestic hot water 9 2 1 Emergency 9 5 Number of zones 4 4 Glycol Filled system overview field setting E 0D Backup he...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...4P644733 1 2021 02 Copyright 2021 Daikin 4P644733 1 0000000P Verantwortung f r Energie und Umwelt...

Reviews: