background image

5 Operation

Operation manual

12

ET9W

Daikin Altherma 3 H HT F

4P644733-1 – 2021.02

Possible read-out information

In menu…

You can read out…

[8.1] 

Energy data

Produced energy, consumed
electricity, and consumed gas

[8.2] 

Malfunction history

Malfunction history

[8.3] 

Dealer information

Contact/helpdesk number

[8.4] 

Sensors

Room, tank or domestic hot
water, outside, and leaving water
temperature (if applicable)

[8.5] 

Actuators

Status/mode of each actuator

Example: 

Domestic hot water

pump ON/OFF

[8.6] 

Operation modes

Current operation mode

Example: 

Defrost/oil return

mode

[8.7] 

About

Version information about the
system

[8.8] 

Connection status

Information about the connection
status of the unit, the room
thermostat and the LAN adapter.

[8.9] 

Running hours

Running hours of specific system
components

5.6

Space heating/cooling control

5.6.1

Setting the space operation mode

About space operation modes

This unit is a heating only model. The system can heat up a space,
but NOT cool down a space.

However,  if  the  kit  EKHVCONV*  is  installed,  the  system  can  cool
down  a  space,  and  you  have  to  tell  the  system  which  space
operation mode to use: heating or cooling.

To tell the system which space operation to use, you can:

You can…

Location

Check which space operation mode is
currently used.

Home screen

Set the space operation mode permanently. Main menu

Restrict automatic changeover according to
a monthly schedule.

To set the space operation mode

1

Go to [4.1]: 

Space heating/cooling

 > 

Operation

mode

2

Select one of the following options:

Heating

: Only heating mode

Cooling

: Only cooling mode

Automatic

The 

operation 

mode 

changes

automatically  between  heating  and  cooling  based
on the outdoor temperature. Restricted per month
according  to  the 

Operation  mode  schedule

[4.2].

To restrict automatic changeover according to a schedule

Conditions: 

You set the space operation mode to 

Automatic

.

1

Go to [4.2]: 

Space heating/cooling

 > 

Operation

mode schedule

.

2

Select a month.

3

For each month, select an option:

Reversible

: Not restricted

Heating only

: Restricted

Cooling only

: Restricted

4

Confirm the changes.

5.6.2

To change the desired room temperature

During room temperature control, you can use the room temperature
setpoint screen to read out and adjust the desired room temperature.

1

Go to [1]: 

Room

.

Room

1

2

Adjust the desired room temperature.

+

21

°C

1

a

b

Room

a

 Actual room temperature

b

 Desired room temperature

If scheduling is on after changing the desired room temperature

▪ The  temperature  will  stay  the  same  as  long  as  there  is  no

scheduled action.

▪ The  desired  room  temperature  will  return  to  its  scheduled  value

whenever a scheduled action occurs.

You  can  avoid  scheduled  behaviour  by  (temporarily)  turning  off
scheduling.

To turn off room temperature scheduling

1

Go to [1.1]: 

Room

 > 

Schedule

.

2

Select 

No

.

5.6.3

To change the desired leaving water
temperature

INFORMATION

The  leaving  water  is  the  water  that  is  sent  to  the  heat
emitters.  The  desired  leaving  water  temperature  is  set  by
your  installer  in  accordance  with  the  heat  emitter  type.
Only adjust the leaving water temperature settings in case
of problems.

You  can  use  the  leaving  water  temperature  setpoint  screen  to  read
out and adjust the desired leaving water temperature.

Summary of Contents for ETVZ16S23EA6V

Page 1: ...Operation manual Daikin Altherma 3 H HT F English Operation manual Daikin Altherma 3 H HT F ETVZ16S18EA6V ETVZ16S23EA6V ETVZ16S18EA9W ETVZ16S23EA9W...

Page 2: ...installer 20 11 1 Configuration wizard 20 11 2 Settings menu 20 1 About this document Thank you for purchasing this product Please Read the documentation carefully before operating the user interface...

Page 3: ...leaning and user maintenance SHALL NOT be made by children without supervision WARNING To prevent electrical shocks or fire Do NOT rinse the unit Do NOT operate the unit with wet hands Do NOT place an...

Page 4: ...has been repaired WARNING Air purging heat emitters or collectors Before you purge air from heat emitters or collectors check if or is displayed on the home screen of the user interface If not you can...

Page 5: ...vention Even if you turn OFF space heating cooling operation C 2 Operation Space heating cooling water pipe freeze prevention if enabled will remain active 1 Go to C 2 Operation Space heating cooling...

Page 6: ...the temperatures Change the temperature Go to the next temperature Confirm changes and proceed More information For more information see also 5 4 Turning operation ON or OFF 411 5 6 Space heating cool...

Page 7: ...Export the current settings i e field settings MMI EEPROM settings schedule timers from the user interface MMI to the USB memory stick LCD screen The LCD screen has a sleeping function After 15 min o...

Page 8: ...nt 1 5 Setpoint range Heating minimum Heating maximum Cooling minimum Cooling maximum 7 2 Time date Hours Minutes Year Month Day Daylight savings time Format 7 3 Holiday Activation From Till 7 4 Quiet...

Page 9: ...failure and system operates in Emergency mode or heat pump is forced off d Current date and time e Smart energy e1 Smart energy is available via solar panels or smart grid e2 Smart energy is currentl...

Page 10: ...in zone Shows the applicable symbol for your main zone emitter type Set the leaving water temperature for the main zone 3 Additional zone Restriction Only displayed if there are two leaving water temp...

Page 11: ...ng operation ON b Space heating cooling operation OFF Tank heating operation 1 6 bar 55 21 35 45 c 1 6 bar 55 21 35 45 d c Tank heating operation ON d Tank heating operation OFF 5 4 2 To turn ON or OF...

Page 12: ...following options Heating Only heating mode Cooling Only cooling mode Automatic The operation mode changes automatically between heating and cooling based on the outdoor temperature Restricted per mo...

Page 13: ...ed to heat up the water to a preset value example Comfort 60 C During the morning you consume hot water and the DHW tank temperature decreases At 14 00 the DHW tank is programmed to heat up the water...

Page 14: ...ule to the other weekdays 5 Program the schedule for Saturday and copy it to Sunday 6 Give the schedule a name To go to the schedule 1 Go to 1 1 Room Schedule 2 Set scheduling to Yes 3 Go to 1 2 Room...

Page 15: ...and confirm the selected character The schedule name can contain up to 15 characters 5 Confirm the new name INFORMATION Not all schedules can be renamed 5 9 Weather dependent curve 5 9 1 What is a wea...

Page 16: ...and proceed 5 9 3 Slope offset curve Slope and offset Define the weather dependent curve by its slope and offset Change the slope to differently increase or decrease the temperature of the leaving wat...

Page 17: ...one Cooling WD curve Additional zone Heating 3 5 Additional zone Heating WD curve Additional zone Cooling 3 6 Additional zone Cooling WD curve Zone Go to Tank Restriction Only available to installers...

Page 18: ...gerant total refrigerant charge in kg 1000 Please contact your installer for more information WARNING FLAMMABLE MATERIAL The refrigerant inside this unit is mildly flammable WARNING Do NOT pierce or b...

Page 19: ...s the domestic hot water heating and space heating stops To manually recover it via the user interface go to the Malfunctioning main menu screen and confirm whether the backup heater can take over the...

Page 20: ...tting Fill in System Indoor unit type read only Backup heater type 9 3 1 read only Domestic hot water 9 2 1 Emergency 9 5 Number of zones 4 4 Glycol Filled system overview field setting E 0D Backup he...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...4P644733 1 2021 02 Copyright 2021 Daikin 4P644733 1 0000000P Verantwortung f r Energie und Umwelt...

Reviews: