5 Operation

Operation manual

7

ET9W
Daikin Altherma 3 H HT F
4P644733-1 – 2021.02

a

b

c

a

Status indicator

b

LCD screen

c

Dials and buttons

Status indicator

The  LEDs  of  the  status  indicator  light  up  or  blink  to  show  the
operating mode of the unit.

LED

Mode

Description

Blinking blue

Standby

The unit is not in operation.

Continuous blue Operation

The unit is in operation.

Blinking red

Malfunction

A malfunction occurred.

See 

"8.1 To display the help text

in case of a malfunction"

 [

4

 18]

for more information.

Slot for WLAN cartridge

With the WLAN cartridge, the installer can connect the system to the
internet.  As  user  you  can  then  control  the  system  via  the  Daikin
Residential  Controller  app. 

Note: 

This  slot  cannot  be  used  for  SD

cards.

USB connector

With a USB memory stick, the installer can:

▪ Update the software. This requires a correct config file on the USB

memory stick.

▪ Import  the  settings  generated  by  E-Configurator  (Heating

Solutions  Navigator)  from  the  USB  memory  stick  to  the  user
interface  (MMI).  This  requires  a  correct  config  file  on  the  USB
memory stick.

▪ Export  the  current  settings  (i.e.  field  settings,  MMI  EEPROM

settings,  schedule  timers)  from  the  user  interface  (MMI)  to  the
USB memory stick.

LCD screen

The  LCD  screen  has  a  sleeping  function.  After  15  min  of  non-
interaction with the user interface, the screen darkens. Pressing any
button or rotating any dial awakens the display.

Dials and buttons

You use the dials and buttons:

▪ To navigate through the screens, menus and settings of the LCD

screen

▪ To set values

a

b

c

d

e

Item

Description

a

Left dial

The LCD shows an arc on the left side of the
display when you can use the left dial.

:  Turn,  then  press  the  left  dial.  Navigate

through the menu structure.

: Turn the left dial. Choose a menu item.

: Press the left dial. Confirm your choice

or go to a submenu.

b

Back button

: Press to go back 1 step in the menu structure.

c

Home
button

: Press to go back to the home screen.

d

Help button

: Press to show a help text related to the current

page (if available).

e

Right dial

The LCD shows an arc on the right side of the
display when you can use the right dial.

: Turn, then press the right dial. Change

a value or setting, shown at the right side of the
screen.

:  Turn  the  right  dial.  Navigate  through

the possible values and settings.

:  Press  the  right  dial.  Confirm  your

choice and go to the next menu item.

Summary of Contents for ETVZ16S23EA6V

Page 1: ...Operation manual Daikin Altherma 3 H HT F English Operation manual Daikin Altherma 3 H HT F ETVZ16S18EA6V ETVZ16S23EA6V ETVZ16S18EA9W ETVZ16S23EA9W...

Page 2: ...installer 20 11 1 Configuration wizard 20 11 2 Settings menu 20 1 About this document Thank you for purchasing this product Please Read the documentation carefully before operating the user interface...

Page 3: ...leaning and user maintenance SHALL NOT be made by children without supervision WARNING To prevent electrical shocks or fire Do NOT rinse the unit Do NOT operate the unit with wet hands Do NOT place an...

Page 4: ...has been repaired WARNING Air purging heat emitters or collectors Before you purge air from heat emitters or collectors check if or is displayed on the home screen of the user interface If not you can...

Page 5: ...vention Even if you turn OFF space heating cooling operation C 2 Operation Space heating cooling water pipe freeze prevention if enabled will remain active 1 Go to C 2 Operation Space heating cooling...

Page 6: ...the temperatures Change the temperature Go to the next temperature Confirm changes and proceed More information For more information see also 5 4 Turning operation ON or OFF 411 5 6 Space heating cool...

Page 7: ...Export the current settings i e field settings MMI EEPROM settings schedule timers from the user interface MMI to the USB memory stick LCD screen The LCD screen has a sleeping function After 15 min o...

Page 8: ...nt 1 5 Setpoint range Heating minimum Heating maximum Cooling minimum Cooling maximum 7 2 Time date Hours Minutes Year Month Day Daylight savings time Format 7 3 Holiday Activation From Till 7 4 Quiet...

Page 9: ...failure and system operates in Emergency mode or heat pump is forced off d Current date and time e Smart energy e1 Smart energy is available via solar panels or smart grid e2 Smart energy is currentl...

Page 10: ...in zone Shows the applicable symbol for your main zone emitter type Set the leaving water temperature for the main zone 3 Additional zone Restriction Only displayed if there are two leaving water temp...

Page 11: ...ng operation ON b Space heating cooling operation OFF Tank heating operation 1 6 bar 55 21 35 45 c 1 6 bar 55 21 35 45 d c Tank heating operation ON d Tank heating operation OFF 5 4 2 To turn ON or OF...

Page 12: ...following options Heating Only heating mode Cooling Only cooling mode Automatic The operation mode changes automatically between heating and cooling based on the outdoor temperature Restricted per mo...

Page 13: ...ed to heat up the water to a preset value example Comfort 60 C During the morning you consume hot water and the DHW tank temperature decreases At 14 00 the DHW tank is programmed to heat up the water...

Page 14: ...ule to the other weekdays 5 Program the schedule for Saturday and copy it to Sunday 6 Give the schedule a name To go to the schedule 1 Go to 1 1 Room Schedule 2 Set scheduling to Yes 3 Go to 1 2 Room...

Page 15: ...and confirm the selected character The schedule name can contain up to 15 characters 5 Confirm the new name INFORMATION Not all schedules can be renamed 5 9 Weather dependent curve 5 9 1 What is a wea...

Page 16: ...and proceed 5 9 3 Slope offset curve Slope and offset Define the weather dependent curve by its slope and offset Change the slope to differently increase or decrease the temperature of the leaving wat...

Page 17: ...one Cooling WD curve Additional zone Heating 3 5 Additional zone Heating WD curve Additional zone Cooling 3 6 Additional zone Cooling WD curve Zone Go to Tank Restriction Only available to installers...

Page 18: ...gerant total refrigerant charge in kg 1000 Please contact your installer for more information WARNING FLAMMABLE MATERIAL The refrigerant inside this unit is mildly flammable WARNING Do NOT pierce or b...

Page 19: ...s the domestic hot water heating and space heating stops To manually recover it via the user interface go to the Malfunctioning main menu screen and confirm whether the backup heater can take over the...

Page 20: ...tting Fill in System Indoor unit type read only Backup heater type 9 3 1 read only Domestic hot water 9 2 1 Emergency 9 5 Number of zones 4 4 Glycol Filled system overview field setting E 0D Backup he...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...4P644733 1 2021 02 Copyright 2021 Daikin 4P644733 1 0000000P Verantwortung f r Energie und Umwelt...

Reviews: