background image

3 About the system

Operation manual

4

ET9W

Daikin Altherma 3 H HT F

4P644733-1 – 2021.02

2.2

Instructions for safe operation

WARNING: MILDLY FLAMMABLE
MATERIAL

The refrigerant inside this unit is mildly
flammable.

WARNING

The appliance shall be stored so as to
prevent mechanical damage and in a
well-ventilated room without
continuously operating ignition sources
(example: open flames, an operating
gas appliance or an operating electric
heater).

WARNING

▪ Do NOT pierce or burn refrigerant

cycle parts.

▪ Do NOT use cleaning materials or

means to accelerate the defrosting
process other than those
recommended by the manufacturer.

▪ Be aware that the refrigerant inside

the system is odourless.

WARNING

The refrigerant inside the unit is mildly
flammable, but normally does NOT
leak. If the refrigerant leaks in the room
and comes in contact with fire from a
burner, a heater, or a cooker, this may
result in fire, or the formation of a
harmful gas.

Turn off any combustible heating
devices, ventilate the room, and
contact the dealer where you
purchased the unit.

Do NOT use the unit until a service
person confirms that the part from
which the refrigerant leaked has been
repaired.

WARNING

Air purging heat emitters or
collectors.

 Before you purge air from

heat emitters or collectors, check if 
or 

 is displayed on the home screen

of the user interface.

▪ If not, you can purge air immediately.

▪ If yes, make sure that the room

where you want to purge air is
sufficiently ventilated. 

Reason:

Refrigerant might leak into the water
circuit, and subsequently into the
room when you purge air from the
heat emitters or collectors.

3

About the system

Depending on the system layout, the system can:

▪ Heat up a space

▪ Cool  down  a  space  (if  a  heating/cooling  heat  pump  model  is

installed)

▪ Produce domestic hot water

INFORMATION

Cooling  is  only  applicable  in  case  a  conversion  kit
(EKHVCONV*) is installed.

3.1

Components in a typical system
layout

g

A

d

b

a

f

e

c

B

C

A

Main zone. 

Example: 

Living room.

B

Additional zone. 

Example: 

Bedroom.

C

Technical room. 

Example: 

Garage.

a

Outdoor unit heat pump

b

Indoor unit heat pump

c

Domestic hot water (DHW) tank

d

User interface of the indoor unit

e

Dedicated Human Comfort Interface (BRC1HHDA used as
room thermostat)

f

Underfloor heating

g

Radiators, heat pump convectors, or fan coil units

4

Quick guide

4.1

User permission level

The  amount  of  information  you  can  read  out  and  edit  in  the  menu
structure depends on your user permission level:

User

: Standard mode

Advanced user

: You can read out and edit more information

Summary of Contents for ETVZ16S23EA6V

Page 1: ...Operation manual Daikin Altherma 3 H HT F English Operation manual Daikin Altherma 3 H HT F ETVZ16S18EA6V ETVZ16S23EA6V ETVZ16S18EA9W ETVZ16S23EA9W...

Page 2: ...installer 20 11 1 Configuration wizard 20 11 2 Settings menu 20 1 About this document Thank you for purchasing this product Please Read the documentation carefully before operating the user interface...

Page 3: ...leaning and user maintenance SHALL NOT be made by children without supervision WARNING To prevent electrical shocks or fire Do NOT rinse the unit Do NOT operate the unit with wet hands Do NOT place an...

Page 4: ...has been repaired WARNING Air purging heat emitters or collectors Before you purge air from heat emitters or collectors check if or is displayed on the home screen of the user interface If not you can...

Page 5: ...vention Even if you turn OFF space heating cooling operation C 2 Operation Space heating cooling water pipe freeze prevention if enabled will remain active 1 Go to C 2 Operation Space heating cooling...

Page 6: ...the temperatures Change the temperature Go to the next temperature Confirm changes and proceed More information For more information see also 5 4 Turning operation ON or OFF 411 5 6 Space heating cool...

Page 7: ...Export the current settings i e field settings MMI EEPROM settings schedule timers from the user interface MMI to the USB memory stick LCD screen The LCD screen has a sleeping function After 15 min o...

Page 8: ...nt 1 5 Setpoint range Heating minimum Heating maximum Cooling minimum Cooling maximum 7 2 Time date Hours Minutes Year Month Day Daylight savings time Format 7 3 Holiday Activation From Till 7 4 Quiet...

Page 9: ...failure and system operates in Emergency mode or heat pump is forced off d Current date and time e Smart energy e1 Smart energy is available via solar panels or smart grid e2 Smart energy is currentl...

Page 10: ...in zone Shows the applicable symbol for your main zone emitter type Set the leaving water temperature for the main zone 3 Additional zone Restriction Only displayed if there are two leaving water temp...

Page 11: ...ng operation ON b Space heating cooling operation OFF Tank heating operation 1 6 bar 55 21 35 45 c 1 6 bar 55 21 35 45 d c Tank heating operation ON d Tank heating operation OFF 5 4 2 To turn ON or OF...

Page 12: ...following options Heating Only heating mode Cooling Only cooling mode Automatic The operation mode changes automatically between heating and cooling based on the outdoor temperature Restricted per mo...

Page 13: ...ed to heat up the water to a preset value example Comfort 60 C During the morning you consume hot water and the DHW tank temperature decreases At 14 00 the DHW tank is programmed to heat up the water...

Page 14: ...ule to the other weekdays 5 Program the schedule for Saturday and copy it to Sunday 6 Give the schedule a name To go to the schedule 1 Go to 1 1 Room Schedule 2 Set scheduling to Yes 3 Go to 1 2 Room...

Page 15: ...and confirm the selected character The schedule name can contain up to 15 characters 5 Confirm the new name INFORMATION Not all schedules can be renamed 5 9 Weather dependent curve 5 9 1 What is a wea...

Page 16: ...and proceed 5 9 3 Slope offset curve Slope and offset Define the weather dependent curve by its slope and offset Change the slope to differently increase or decrease the temperature of the leaving wat...

Page 17: ...one Cooling WD curve Additional zone Heating 3 5 Additional zone Heating WD curve Additional zone Cooling 3 6 Additional zone Cooling WD curve Zone Go to Tank Restriction Only available to installers...

Page 18: ...gerant total refrigerant charge in kg 1000 Please contact your installer for more information WARNING FLAMMABLE MATERIAL The refrigerant inside this unit is mildly flammable WARNING Do NOT pierce or b...

Page 19: ...s the domestic hot water heating and space heating stops To manually recover it via the user interface go to the Malfunctioning main menu screen and confirm whether the backup heater can take over the...

Page 20: ...tting Fill in System Indoor unit type read only Backup heater type 9 3 1 read only Domestic hot water 9 2 1 Emergency 9 5 Number of zones 4 4 Glycol Filled system overview field setting E 0D Backup he...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...4P644733 1 2021 02 Copyright 2021 Daikin 4P644733 1 0000000P Verantwortung f r Energie und Umwelt...