![background image](http://html1.mh-extra.com/html/daikin/erlq011ca/erlq011ca_installers-reference-manual_2460297006.webp)
Installer reference guide
5
EHBH/X16
Daikin Altherma - Low Temperature Split
4P313776-1 – 2012.05
4 About the units and options
3.1.2 To remove the accessories from the indoor
unit
The installation manual indoor unit, operation manual, and CD are
located in the upper part of the box. Follow the procedure below to
remove the other accessories.
1
Remove the screws at the bottom of the unit.
2
Tilt the bottom side of the front panel upwards and remove it.
3
Remove the accessories.
4
About the units and options
4.1
Identification
4.1.1 Identification label: Indoor unit
Location
Model identification
Example: E HB H 04 CA 3V
4.2
Possible combinations of units and options
4.2.1 List of options for indoor unit
User interface (EKRUCAL1, EKRUCAL2)
The user interface is delivered as an accessory with the unit. An
additional user interface is optionally available.
The additional user interface can be connected:
Q
To have both:
Q
control close to the indoor unit
Q
room thermostat functionality in the principal space to be
heated
Q
To have an interface containing other languages
The additional user interface EKRUCAL1 contains the 6 common
languages: English, German, French, Dutch, Italian, Spanish.
The additional user interface EKRUCAL2 contains other languages:
English, Swedish, Norwegian, Czech, Turkish, Portuguese.
Languages on the user interface can be uploaded by PC software or
copied from an user interface to the other.
For installation instructions, see "7.4.5 To connect the user
interface" on page 27.
Room thermostat (EKRTWA, EKRTR1)
You can connect an optional room thermostat to the indoor unit. This
thermostat can either be wired (EKRTWA) or wireless (EKRTR1).
For installation instructions, see the installation manual of the room
thermostat and addendum book for optional equipment.
a
General safety precautions
b
Addendum book for optional equipment
c
Indoor unit installation manual
d
Operation manual
e
CD
f
User interface kit: user interface, 4 fixing screws, 2 plugs
g
Shut-off valve
h
User interface cover
i
Hinges for user interface cover
2x
f+g
d
e
i
a
1x
b
1x
c
1x
d
1x
g
2x
h
1x
2x
f
1x
e
1x
NOTICE
When installing or servicing several units at the same time,
make sure NOT to switch the service panels between
different models.
Code
Description
E
European model
HB
HB=Wall-mounted indoor unit
H
Q
H=Heating only
Q
X=Heating/cooling
04
Capacity class:
Q
04=4 kW
Q
08=8 kW
Q
16=16 kW
CA
Series
3V
Backup heater model
Q
3V
Q
9W
Summary of Contents for ERLQ011CA
Page 83: ......