background image

ERHQ011~W1 + ERLQ011~W1

Outdoor unit for air to water heat pump

4PW54249-1

Installation manual

16

W

IRING

 

DIAGRAM

A1P~A4P ................... Printed circuit board

BS1~BS4 ................... Push button switch

C1~C4 ....................... Capacitor

DS1............................ DIP switch

E1H............................ Bottom plate heater

E1HC ......................... Crankcase heater

F1U~F9U ................... Fuse

HAP (A1P) ................. Service monitor (green)

HAP (A2P) ................. Service monitor (green) (for W1 models only)

H1P~H7P (A1P) ........ Service monitor (orange) (for W1 models only)

H1P~H7P (A2P) ........ Service monitor (orange)

K1M, K2M.................. Magnetic contactor (for W1 models only)

K1R~K4R .................. Magnetic relay

K10R, K11R............... Magnetic relay (for V3 models only)

L1R~L4R ................... Reactor

M1C ........................... Motor (compressor)

M1F ........................... Motor (fan) (upper)

M2F ........................... Motor (fan) (lower)

PS.............................. Switching power supply

Q1DI .......................... Earth leakage circuit breaker (field supply)

R1~R4 ....................... Resistor

R1T............................ Thermistor (air)

R2T............................ Thermistor (discharge)

R3T............................ Thermistor (suction pipe)

R4T ............................Thermistor (heat exchanger)

R5T ............................Thermistor (heat exchanger middle)

R6T ............................Thermistor (liquid)

R7T ............................Thermistor (fin) (for W1 models only)

R10T ..........................Thermistor (fin) (for V3 models only)

RC..............................Signal receiver circuit (for V3 models only)

S1NPH .......................Pressure sensor

S1PH..........................Pressure switch (high)

TC ..............................Signal transmission circuit (for V3 models

only)

V1R ............................Power module (for V3 models only)

V1R, V2R ...................Power module (for W1 models only)

V2R, V3R ...................Diode module (for V3 models only)

V3R ............................Diode module (for W1 models only)

V1T ............................Insulated gate bipolar transistor (for V3 models

only)

X1M............................Terminal strip

X1Y ............................Connector

X6A ............................Connector (option)

X77A ..........................Connector

Y1E ............................Expansion valve

Y1S ............................Solenoid valve (4 way valve)

Y3S ............................Solenoid valve (for W1 models only)

Z1C~Z9C ...................Noise filter

Z1F~Z4F ....................Noise filter

: Wire clamp

L

: Live

: Terminal strip

N

: Neutral

: Connector

: Relay connector

BLK

: Black

ORG

: Orange

: Field wiring

BLU

: Blue

RED

: Red

: Protective earth screw

BRN

: Brown

WHT

: White

: Noiseless earth

GRN

: Green

YLW

: Yellow

NOTE 1

This wiring diagram only applies to the outdoor unit

NOTE 4

Refer to the option manual for connecting wiring to X6A/X77A

NOTE 5

Refer to the wiring diagram sticker (on back of front panel) on how to use BS1~BS4 and DS1 switch

NOTE 6

Do not operate the unit by short-circuiting protection device S1PH

NOTE 8

Confirm the method of setting the selector switches (DS1) by service manual. Factory setting of all switches: 'OFF'

NOTE 9

Option: Option
Wiring depending on model: Wiring depending on model

Summary of Contents for ERLQ011BAV3

Page 1: ...STALLATION MANUAL ERHQ011BAV3 ERHQ014BAV3 ERHQ016BAV3 ERHQ011BAW1 ERHQ014BAW1 ERHQ016BAW1 ERLQ011BAV3 ERLQ014BAV3 ERLQ016BAV3 ERLQ011BAW1 ERLQ014BAW1 ERLQ016BAW1 Outdoor unit for air to water heat pum...

Page 2: ...1 2 4 5 6 3 1 3 2 4 5 A B A E B C D H H L A A B2 B2 B2 C C D1 D1 D1 D2 D2 D2 D2 D2 E E H H L1 L1 L1 L2 L2 L2 A A B1 B1 B1 B1 B1 B1 B2 B2 B2 C C D1 D1 D1 D2 D2 D2 D2 D2 E E H H L1 L1 L1 L2 L2 L2 1 1 2...

Page 3: ...prescrizioni per 07 v v v 08 de acordo com o previsto em 09 10 under iagttagelse af bestemmelserne i 11 enligt villkoren i 12 gitt i henhold til bestemmelsene i 13 noudattaen m r yksi 14 za dodr en u...

Page 4: ...t does not exceed the concentration limit in the event of a leakage Otherwise this may lead to an accident due to oxygen depletion Be sure to use only the specified accessories and parts for installat...

Page 5: ...ns on page 3 Improper drain piping may cause water leakage and make the furnitures get wet Install the indoor and outdoor units power wire and connecting wire at least 1 meter away from televisions or...

Page 6: ...rinding works where a lot of dust is created the unit must be covered Do not place any objects or equipment on top of the unit top plate Do not climb sit or stand on top of the unit Be sure that suffi...

Page 7: ...l not affect the unit If lateral snowfall is possible make sure that the heat exchanger coil is not affected by the snow if necessary construct a lateral canopy PRECAUTIONS ON INSTALLATION Check the s...

Page 8: ...REFRIGERANT PIPE SIZE AND ALLOWABLE PIPE LENGTH A Location of the 2 fixation holes on the front side of the unit B Location of the 2 fixation holes on the rear side of the unit C Wires field supply S...

Page 9: ...ded when passing copper tubes through walls Piping should be mounted so that the flare is not subjected to mechanical stress Flaring guidelines Flares should not be re used New ones should be made in...

Page 10: ...t the operating pressure will be low for example when cooling will be performed while the outside air temperature is low sufficiently seal the flare nut in the stop valve on the gas line with silicon...

Page 11: ...tion Be careful not to let the indoor and outdoor piping come into contact with the compressor terminal cover If the liquid side piping insulation might come into contact with it adjust the height as...

Page 12: ...inimum gauge pressure of 0 2 MPa 2 bar Never set the gauge pressure higher than the maximum operation pressure of the unit i e 4 0 MPa 40 bar 2 2 Test for leaks by applying a bubble test solution to a...

Page 13: ...syphon attached or not and position the cylinder accordingly NOTE National implementation of EU regulation on certain fluorinated greenhouse gases may require to provide the appropriate official nati...

Page 14: ...ally 5 Once operation stops after 3 to 5 minutes close the liquid stop valve and the gas stop valve 6 The pump down operation is now finished The remote controller may display U4 and the indoor pump m...

Page 15: ...re the wiring in the order shown below 1 Secure the earth wire to the stop valve attachment plate so that it does not slide 2 Secure the earth wire to the stop valve attachment plate one more time alo...

Page 16: ...r unit for wiring of indoor unit etc Attach an earth leakage circuit breaker and fuse to the power supply line See figure 6 In wiring make certain that prescribed wires are used carry out complete con...

Page 17: ...ase protection circuit forced the unit to stop check if all phases are existing If this is the case shut off the power supply to the unit and replace two of three phases Turn on power again and start...

Page 18: ...ntling of the unit treatment of the refrigerant of oil and of other parts must be done in accordance with relevant local and national legislation UNIT SPECIFICATIONS Technical specifications Electrica...

Page 19: ...y S1NPH Pressure sensor S1PH Pressure switch high TC Signal transmission circuit for V3 models only V1R Power module for V3 models only V1R V2R Power module for W1 models only V2R V3R Diode module for...

Page 20: ...4PW54249 1 Copyright Daikin...

Reviews: