13/13
Breadcrumb Field code
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
9.I
[E-0C]
R/W
0: Without hydraulic separator / no
direct pump
1: With hydraulic separator / no direct
pump
2: With hydraulic separator / with direct
pump
9.I
[E-0D]
R/W
0: No
1: Yes
9.I
[E-0E]
0
9.I
[F-00]
R/W
0: Disabled
1: Enabled
9.I
[F-01]
R/W
10~35°C, step: 1°C
20°C
9.I
[F-02]
3
9.I
[F-03]
5
9.I
[F-04]
0
9.I
[F-05]
0
9.I
[F-06]
R/W
0: Disabled
1: Enabled
9.I
[F-07]
R/W
0: Enabled
1: Disabled
9.I
[F-08]
R/W
0: Disabled
1: Enabled
9.I
[F-09]
R/W
0: Disabled
1: Enabled
9.I
[F-0A]
0
9.I
[F-0B]
R/W
0: No
1: Yes
9.I
[F-0C]
R/W
0: No
1: Yes
9.I
[F-0D]
R/W
0: Continuous
1: Sample
2: Request
9.I
[F-0E]
R/W
10~35 kW, step: 1kW
20 kW
Bizone kit settings
9.P.1
[E-0B]
R/W
0: Not installed
1: -
2: Bizone kit installed
9.P.2
[E-0C]
R/W
0: Without hydraulic separator / no
direct pump
1: With hydraulic separator / no direct
pump
2: With hydraulic separator / with direct
pump
9.P.3
[7-0A]
R/W
20~95%, step 5%
95%
9.P.4
[7-0B]
R/W
20~95%, step 5%
95%
9.P.5
[7-0C]
R/W
20~300 sec, step 5 sec
125 sec
Main zone pump fixed PWM
--
Pump operation allowed outside range.
--
--
Pump operation during flow abnormality.
--
Close shut-off valve during thermo OFF?
Bizone kit installed
Bizone system type
Add zone pump fixed PWM
Tank heating support_max
Enable Tank Boiler?
Efficiency calculation
Close shut-off valve during cooling?
What bizone system type is installed?
Is the system filled with glycol ?
Continuous heating defrost enable
Mixing valve turning time
What is the pump operation mode?
Above which outdoor temperature is cooling allowed?
--
--
(*1) 300 Tank_(*2) 500 Tank_
(*3) *X*_(*4) *H*_(*5) *B*_
(*6) EKECBUA3V_(*7) EKECBUA6V_(*8) EKECBUA9W_
(*9) BUH less
4P670987-1A - 2022.02