E260AC

Domestic hot water tank for air to water heat pump system

4PW64052-1 – 08.2010

Installation manual

7

6

Push the motor on the sleeve. 

Make sure not to rotate the sleeve during this action, so as to
maintain the valve position as set during step 

4

.

7

Put the turn knob on the valve motor cover as shown below.

Make sure that the turn knob is completely pushed in to allow
the turn knob being operated automatically by the unit. If the
turn knob is lifted slightly, manual operation is possible.

8

Perform the wiring in the indoor unit switch box in accordance
with the following figure: (make sure power supply is
switched off)

Make sure to follow the appropriate wiring routing inside of
the unit (this wiring routing can be found in the installation
manual of the indoor unit).
Refer also to the wiring diagram delivered with the indoor
unit.

5

Mount the tank module on top of the indoor unit.

6

Connect the flexible hoses as indicated in 

figure 4

figure 5

,

figure 6

 and 

figure 7

.

The 2 flexible hoses with quick coupling connections on both
sides must be connected to the foreseen coil connection (for
EKHBRD units see 

figure 4

, for EKHVH/X units see 

figure 5

,

for EKHVMRD units see 

figure 6

, for EKHVMYD units see

figure 7

).

The 2 flexible hoses with quick coupling connection on one
side and threaded connection coupling on the other side
must be connected to the hot water outlet and cold water
inlet (they have to be routed out from the rear plate as
indicated in 

figure 4

figure 5

figure 6

figure 7

). Depending

on the installation location (left or right side installation),
punch the required right or left knockout holes out of the rear
plate. Apply the grommet to the edges of the knocked out
holes to protect the flexible hoses.
If the recirculation connection is used, connect a tube with
threaded connection to this hole and guide it through a hole
in the rear plate too (for EKHBRD units see 

figure 4

, for

EKHVH/X units see 

figure 5

, for EKHVMRD units see

figure 6

, for EKHVMYD units see 

figure 7

).

7

Fix the side bottom decoration panels of the domestic hot water
tank to the indoor unit.

8

Connect the pressure relief valve (field supply, opening pressure
maximum 10 bar) and the drain.

Room heating

Domestic hot water tank

EKHBRD / EKHVMR/YD

EKHVH/X

X2M

X2M

3

4

5

8

9

10

3-way valve

3-way valve

BLU

BLK

BRN

BRN

BLU

BLK

N

Y

L

L

N

Y

Because of the weight of the domestic hot water
tank, it is advised to handle and lift it with two
persons.

Refer to the figure below and make sure that the
positioning guides on all four corners of the
domestic hot water tank bottom perfectly match
on the four positioning guides of the indoor unit
top when mounting the tank module.

1

Hot water out connection (G 3/4" Female)

2

Cold water in connection (G 3/4" Female)

3

Hot water out connection at the bottom of the tank (quick 
coupling)

4

Cold water in connection at the bottom of the tank (quick 
coupling)

5

Recirculation connection (G 1/2" Male)

6

Flow inlet connection from the main indoor unit 
(quick coupling)

7

Return outlet connection to the main indoor unit 
(quick coupling)

8

3-way valve

9

Flow inlet connection from the main indoor unit at the bottom 
of the tank (quick coupling)

10

Return outlet connection to the main indoor unit at the 
bottom of the tank (quick coupling)

It is recommended to install a shut off valve to the cold
water inlet. Close this shut off valve during periods of
absence to avoid damage to the surroundings in case
water should leak.

1

Decoration panel

2

Quick fixation hole

3

Fasten with 2 screws

2x

2x

2x

2x

2

2

1

1

1

1

2

2

3

3

3

3

4PW64052-1_digital_EN.book  Page 7  Monday, August 30, 2010  8:48 AM

Summary of Contents for EKHTS200AC

Page 1: ...INSTALLATION MANUAL EKHTS200AC EKHTS260AC EKHTSU200AC EKHTSU260AC EKUHWHTA Domestic hot water tank for air to water heat pump system...

Page 2: ...1 3 2x 5x 1 3 4 2 1x 340 mm 1x B A C 1x 1x 7 5 6 10 11 11 12 2 1 5 4 6 8 3 9 1 2 7 772 902 1032 H 120 6 0 778 694 443 600 300 9 3 10 4 5 A 250 600 30 50 30 A EKHBRD EKHVMR YD EKHVH X 250 250 300 2 1...

Page 3: ...ification ACCESSORIES Accessories supplied with the domestic hot water tank See figure 1 Optional equipment EKFMAHTB Connection kit for installation of the domestic hot water tank on the floor next to...

Page 4: ...G 3 4 Female B T piece field supply C Pressure relief valve connection field supply D Pressure relief valve field supply E Recirculation connection G 1 2 Male F Thermistor socket G Flow inlet connect...

Page 5: ...ck if all domestic hot water tank accessories are enclosed see Accessories on page 1 3 Remove the decoration panels and top plate of the indoor unit Take away the decoration panels by removing the 2 b...

Page 6: ...ing connections 2 Installation position The 3 way valve must be installed in the indoor unit 3 Unpack the 3 way valve body and 3 way valve motor Verify that following accessories are provided with the...

Page 7: ...l 5 5 Install the 3 way valve body in the piping Refer to the figure below before making the connection For EKHBRD indoor units only For EKHVMRD indoor units only Avoid contact between hot piping and...

Page 8: ...00 260AC Domestic hot water tank for air to water heat pump system 4PW64052 1 08 2010 For EKHVMYD indoor units only For EKHVH X indoor units only 8 9 4 A 5 6 1 1 3 2 7 8 A 7 6 2 1 10 10 1 1 13 12 9 4...

Page 9: ...he edges of the knocked out holes to protect the flexible hoses If the recirculation connection is used connect a tube with threaded connection to this hole and guide it through a hole in the rear pla...

Page 10: ...r supply cable must always be at least 25 mm to prevent electromagnetic interference on the thermistor cable 1 Plug the thermistor cable connector in the socket X11A EKHBRD EKHVMR YD A3P or X9A EKHVH...

Page 11: ...ter taps after all air is expelled 4 Check for leaks 5 Manually operate the pressure relief valve to ensure free water flow through the discharge pipe turn knob counterclockwise Refer to Main componen...

Page 12: ...repair activity always switch off the circuit breaker on the supply panel remove the fuses or open the protection devices of the unit Make sure that before starting any maintenance or repair activity...

Page 13: ...l Stainless steel Stainless steel Overall dimensions h x l x w mm 1335 x 600 x 695 1610 x 600 x 695 Connections Quick coupling G 3 4 F Quick coupling G 3 4 F Inspection opening G1 2 M Recirculation co...

Page 14: ...1 2 1 2 3 3 9 9 5 5 4 4 10 10 10 6 6 7 7 8 8 9 8 6 9 1 2 5 EKHVH X 4 EKHBRD 1 2 9 3 9 3 7 6 7 6 8 8 10 10 10 4 4 8 5 5 4 5...

Page 15: ...1 2 1 2 3 3 9 9 5 5 4 4 10 10 10 6 6 7 7 8 8 9 8 6 9 1 2 1 2 3 3 9 9 5 5 4 4 10 10 10 8 6 6 8 8 7 7 9 6 9 7 EKHVMYD 6 EKHVMRD 6 7...

Page 16: ...4PW64052 1 08 2010 Copyright 2010 Daikin...

Reviews: