![Daikin EKHTS200AC Installation Manual Download Page 13](http://html1.mh-extra.com/html/daikin/ekhts200ac/ekhts200ac_installation-manual_3367594013.webp)
E260AC
Domestic hot water tank for air to water heat pump system
4PW64052-1 – 08.2010
Installation manual
11
D
ISPOSAL
REQUIREMENTS
Dismantling of the unit and treatment of parts must be done in
accordance with relevant local and national legislation.
T
ECHNICAL
SPECIFICATIONS
Domestic hot water tank specifications
N
OTES
EKHTS200AC
EKHTS260AC
Storage capacity
(l)
200
260
Internal heat exchanger
volume
(l)
7.5
7.5
Material
Stainless steel
Stainless steel
Overall dimensio
ns
(h x l x w)
(mm)
1335 x 600 x 695
1610 x 600 x 695
Connections
Quick coupling/
G 3/4" F
Quick coupling/
G 3/4" F
Inspection opening
G1/2" M
Recirculation
connection
G1/2" M
Recirculation
connection
Weight (empty)
70
78
Mounting
On top of indoor unit
or floor mounted
On top of indoor unit
or floor mounted
Maximum pressure
domestic hot water tank
(bar)
10
10
Maximum primary
working pressure
(heating side)
(bar)
3
3
Maximum
temperature
domestic hot
water
EKHBRD
(°C)
75
75
EKHVMY/RD
(°C)
60
60
EKHVH/X
(°C)
60
60
Maximum
temperature
heat
exchanger
EKHBRD
(°C)
85
85
EKHVMY/RD
(°C)
60
60
EKHVH/X
(°C)
65
65