5
|
About the units and options
Installer reference guide
27
ERGA04~08EA + 08S18+23EA
Daikin Altherma 3 R F
4P629093-1A – 2021.11
5.1.2 Identification label: Indoor unit
Location
Model identification
Example:
E HV Z 04 S 18 EA 6V
Code
Description
E
European model
HV
Floor-standing indoor unit with integrated tank
Z
Dual-zone model
04
Capacity class
S
Integrated tank material: Stainless steel
18
Integrated tank volume
EA
Model series
6V
Backup heater model
5.2 Combining units and options
INFORMATION
Certain options may NOT be available in your country.
5.2.1 Possible options for the outdoor unit
Drain pan kit (EKDP008D)
The drain pan kit is required to gather the drain from the outdoor unit. The drain
pan kit consists of:
▪
Drain pan
▪
Installation brackets
For installation instructions, see the installation manual of the drain pan.
Drain pan heater (EKDPH008CA)
The drain pan heater is required to avoid freezing-up of the drain pan.
It is recommended to install this option in colder regions with possible low ambient
temperatures or heavy snowfall.
For installation instructions, see the installation manual of the drain pan heater.
U-beams (EKFT008D)
The U-beams are installation brackets on which the outdoor unit can be installed.
It is recommended to install this option in colder regions with possible low ambient
temperatures or heavy snowfall.
For installation instructions, see the installation manual of the outdoor unit.