6
|
Application guidelines
Installer reference guide
37
ERGA04~08EA + 08S18+23EA
Daikin Altherma 3 R F
4P629093-1A – 2021.11
6.3.4 DHW pump for instant hot water
Setup
a
b
c
d
a
Cold water IN
b
Hot water OUT (shower (field supply))
c
DHW pump (field supply)
d
Recirculation connection
▪
By connecting a DHW pump, instant hot water can be available at the tap.
▪
The DHW pump and the installation are field supply and the responsibility of the
installer. For the electrical wiring, see
"9.3.5 To connect the domestic hot water
109].
▪
For more information about connecting the recirculation connection, see
"8.6.4 To connect the recirculation piping"
91].
Configuration
▪
122].
▪
You can program a schedule to control the DHW pump via the user interface. For
more information, see the user reference guide.
6.3.5 DHW pump for disinfection
Setup
a
b
c
d
e
a
Cold water IN
b
Hot water OUT (shower (field supply))
c
DHW pump (field supply)
d
Heater element (field supply)
e
Non‑return valve (field supply)
▪
The DHW pump is field-supplied and its installation is the responsibility of the
installer. For the electrical wiring, see
"9.3.5 To connect the domestic hot water
109].