2
x
Product description
Daikin Altherma EHS(X/H)
Daikin Altherma integrated solar unit
008.1420944 – 05/2014
Operating instructions
11
Tab. 2-1 Legend from fig. 2-2 to fig. 2-5
1
Solar - flow or connection for addition-
al heat source (1" IG)
2
Cold water flow (1" AG)
3
Hot water flow (1" AG)
4
Heating flow (1" AG)*
5
Heating return (1" AG)*
6
Circulation pump
7a
Recommended accessories:
non-return valves (2 pcs.)
9
Storage tank (double walled jacket made
of polypropylene with PUR hard foam heat
insulation)
10
Filling and drainage connection or
Solar - Return flow connection
11
Mount for solar R3 controller or handle
12
Heat exchanger (stainless steel) for drink-
ing water heating
13
Heat exchanger (stainless steel) for stor-
age tank charging or heating support
14
Heat exchanger (stainless steel) for pres-
surised solar storage tank charging
15
Connection for optional electrical backup
heater (R 1½" IG)
16
Solar inflow layering pipe
17
Fill level indicator (tank water)
18
Optional: Electrical backup heater
(EKBUxx)
19
Submersible sensor sleeve for storage
tank temperature sensor t
DHW1
and t
DHW2
20
Unpressurised storage tank water
21
Solar zone
22
Hot water zone
23
Safety overflow connection
24
Mount for handle
25
Type plate
26
Protective cover
27
Solar - Return
28
Solar - Flow (3/4" IG)
(nur Typ Daikin Altherma EHS(X/H)B)
29
Solar - Return flow (3/4" IG)
(nur Typ Daikin Altherma EHS(X/H)B)
30
Panel heat exchanger
31
Liquid-side coolant connection
Daikin Altherma EHS(X/H)
...04P30A/08PxxA:
Cu Ø 6.4 mm (1/4"),
Daikin Altherma EHS(X/H)...16P50A:
Cu Ø 9.5 mm (3/8")
32
Connection to coolant gas line
Cu Ø 15,9 mm (5/8")
3UVB1
3-way diverter valve (internal heat genera-
tor circuit)
3UV DHW
3 way diverter valve (hot water/heating)
DS Pressure sensor
FLS (t
R1
/ V1)
Return flow temperature and flow sensor
t
DHW1
, t
DHW2
Tank temperature sensor
t
R2
Return temperature sensor
t
V1,
t
V2
Feed temperature sensors
t
V, BH
Flow temperature sensor backup heat-
er
RoCon B1
Operating section Daikin Altherma
EHS(X/H) control unit
EKSRPS3B
Optional:
Daikin R3 solar control and
pump unit
Safety devices
Observe tightening torque!
AG Male thread
IG
Female thread
*
Ball cock (1" IG) is supplied with the equip-
ment