Operation
Daikin Altherma EHS(X/H)
Daikin Altherma integrated solar unit
008.1420944 – 05/2014
Operating instructions
21
Tab. 3-8 Factory setting for the permanent switching time programmes
Temporary timer programmes
For a specific situation there are 4
temporary programmes
available,
which
deactivate the permanent timer programmes
or the current operating mode for
the duration of their validity
.
The symbol of the temporary time program is displayed in the
header line of the standard display, as long as the time program
is active.
1.
[Party]:
Immediate one-off extension of the room
heating
a) If an automatic programme is activated, the last
applicable switching cycle is always extended. In the time
before switching cycle 1, the target room temperature set
in the parameter [T-Room 1 Setpoint] applies.
b) In all other operating modes, the target room temperature
set in the parameter [T-Room 1 Setpoint] applies.
– The hot water generation is not affected.
– The time programme runs for the set time period after acti-
vation.
2.
[Away]:
Immediate one-off setback
up to 6 hours
– The system operates in economy mode according to the
room temperature set in the rotary switch setting
"Set
Temp Night"
in the parameter [T-Absence].
– The hot water generation is not affected.
– The time programme runs for the set time period after acti-
vation.
3.
[Holiday]:
One-off calendar-controlled presence
.
– The system operates exclusively in accordance with the
"Sunday" settings in the [HC Program 1].
– The hot water generation operates exclusively in accord-
ance with the "Sunday" settings in the [DHW Program 1].
4.
[Vacation]:
One-off calendar-controlled reduction
.
– The system only operates in economy mode according to
the room temperature set in the rotary switch setting
"Set
Temp Night"
in the parameter [T-Absence].
– Hot water generation according to the set temperatures
and switching cycles in the hot water time programme
[DHW Program 1] (see section 3.4.5).
– The calendar-controlled programme [Vacation] is
not
started
if the operating mode [Standby] or [Manual Oper-
ation] is active on the set start date.
3.4.8 System settings
We undertake the basic settings for the Controller RoCon HP and
the system configurations for the installation environment of the
Daikin Altherma EHS(X/H), the direct heating circuit, the hot
water generation and any optionally connected components in
the rotary switch setting
"Configuration"
.
Depending on access authority (user or expert), various different
parameters are available. Certain parameters are only acces-
sible to the heating expert.
Setting the Language, Date, Time
●
Place the rotary switch in the
"Configuration"
position.
An overview is displayed.
Switching cycle 1
Switching cycle 2
Switching cycle 3
Time period
On
Off
On
Off
On
Off
Room heating / Room cooling
Temperature setting
[T-Room 1 Setpoint]: 20 °C
[T-Room 2 Setpoint]: 20 °C
[T-Room 3 Setpoint]: 20 °C
[T-Reduced]: 10 °C
"HC Program 1"
Monday - Friday
06:00
22:00
- - : - -
- - : - -
- - : - -
- - : - -
Saturday, Sunday
07:00
23:00
- - : - -
- - : - -
- - : - -
- - : - -
"HC Program 2"
Monday - Friday
06:00
08:00
- - : - -
- - : - -
- - : - -
- - : - -
Saturday, Sunday
07:00
23:00
- - : - -
- - : - -
- - : - -
- - : - -
Domestic hot water generation
Temperature setting
[T-DHW Setpoint 1]: 48 °C
[T-DHW Setpoint 2]: 48 °C
[T-DHW Setpoint 3]: 48 °C
"DHW Program 1"
Monday - Sunday
00:00
24:00
- - : - -
- - : - -
- - : - -
- - : - -
"DHW Program 2"
Monday - Friday
05:00
21:00
- - : - -
- - : - -
- - : - -
- - : - -
Saturday, Sunday
06:00
22:00
- - : - -
- - : - -
- - : - -
- - : - -
"Circulation Time"
Monday - Friday
05:00
21:00
- - : - -
- - : - -
- - : - -
- - : - -
Saturday, Sunday
06:00
22:00
- - : - -
- - : - -
- - : - -
- - : - -
The following temporary time programmes may be
interrupted anytime by the manually change of the
operating mode.
An internal pre-programmed calendar ensures auto-
matic time reset at the annually recurring
summer/winter time changes.