Operating instructions
36
Daikin Altherma EHS(X/H)
Daikin Altherma integrated solar unit
008.1420944 – 05/2014
6
x
Parameter settings
6.5
Rotary switch setting: Set Temp Day
6.6 Rotary switch setting: Set Temp Night
6.7 Rotary switch setting: DHW Set Temp
Parameter
Designation
Access
Setting range
Min / Max
Factory
setting
Incre-
ment
BE
HF
T-Room 1 Setpoint
Target room temperature for the 1st switching cycle of the timer programmes [Automatic 1] and
[Automatic 2].
E
E
5 - 40°C
20 °C
0.5 °C
T-Room 2 Setpoint
Target room temperature for the 2nd switching cycle of the timer programmes [Automatic 1]
and [Automatic 2].
E
E
5 - 40°C
20 °C
0.5 °C
T-Room 3 Setpoint
Target room temperature for the 3rd switching cycle of the timer programmes [Automatic 1]
and [Automatic 2].
E
E
5 - 40°C
20 °C
0.5 °C
Tab. 6-7 Parameter in rotary switch setting "Set Temp Day"
Parameter
Designation
Access
Setting range
Min / Max
Factory
setting
Incre-
ment
BE
HF
T-Reduced
Target room temperature for the setback times for the permanent timer programmes
[Automatic 1] and [Automatic 2].
E
E
5 - 40°C
15 °C
0.5 °C
T-Absence
Target room temperature for the setback times for the temporary timer programmes [Away]
and [Vacation].
E
E
5 - 40°C
15 °C
0.5 °C
Tab. 6-8 Parameter in rotary switch setting "Set Temp Night"
Parameter
Designation
Access
Setting range
Min / Max
Factory
setting
Incre-
ment
BE
HF
T-DHW Setpoint 1
Target hot water temperature for the 1st switching cycle of the timer programmes [Automatic 1]
and [Automatic 2].
E
E
10 - 70°C
48 °C
1 °C
T-DHW Setpoint 2
Target hot water temperature for the 2nd switching cycle of the timer programmes
[Automatic 1] and [Automatic 2].
E
E
10 - 70°C
48 °C
1 °C
T-DHW Setpoint 3
Target hot water temperature for the 3rd switching cycle of the timer programmes [Automatic 1]
and [Automatic 2].
E
E
10 - 70°C
48 °C
1 °C
Tab. 6-9 Parameter in rotary switch setting "DHW Set Temp"