![Daikin EHBH04DA6V Installation Manual Download Page 7](http://html1.mh-extra.com/html/daikin/ehbh04da6v/ehbh04da6v_installation-manual_2460488007.webp)
4 Installation
Installation manual
7
EHBH/X04+08DA
Daikin Altherma – Low temperature split
4P495266-1 – 2017.06
2
2
1
3
2
If you have to connect electrical wiring, remove the switch box
cover.
4×
3
If you have to do work behind the switch box, open the switch
box.
2×
1
2
4
If you have to do work behind the lower front panel or upload
new software into the user interface, open the lower front panel.
1
2
3
2×
5
Optional: Remove the lower front panel.
NOTICE
If you remove the lower front panel with integrated user
interface, also disconnect the cables from the back of the
user interface inside the front panel, to avoid damaging
them.
3
1
2
4.2
Mounting the indoor unit
4.2.1
To install the indoor unit
1
Fix the wall bracket (accessory) to the wall (level) with 2 Ø8 mm
bolts.
2×
a
a
Optional: If you want to fix the unit to the wall from inside
the unit, provide an additional screw plug.
2
Lift the unit.