3

WARNING

To avoid property damage, personal injury or death, do not 

use this unit if any part has been under water. Immediately 

call a qualified service technician to inspect the furnace 

and to replace any part of the control system and any gas 

control having been under water. 

WARNING

This unit must not be used as a “construction heater” during 

the finishing phases of construction on a new structure. 

This type of use may result in premature failure of the unit 

due to extremely low return air temperature and exposure 

to corrosive or very dirty atmospheres. 

WARNING

To prevent the risk of property damage, personal injury, or 

death, do not store combustible materials or use gasoline 

or other flammable liquids or vapors in the vicinity of this 

appliance. 

WARNING

Do not connect to or use any device that is not design cer-

tified by the manufacturer for use with this unit. Serious 

property damage, personal injury, reduced unit perfor-

mance and/or hazardous conditions may result from the use 

of such non-approved devices. 

WARNING

HIGH VOLTAGE!

Disconnect all power before servicing or in-

stalling this unit. Multiple power sources may 

be present. Failure to do so may cause proper-

ty damage, personal injury or death. 

WARNING

Connecting unit duct work to unauthorized heat producing 

devices such as a fireplace insert, stove, etc. may result in 

property damage, fire, carbon monoxide poisoning, explo-

sion, personal injury or death.

WARNING

This product contains or produces a chemical or chemicals 

which may cause serious illness or death and which are 

known to the State of California to cause cancer, birth de-

tects or other reproductive harm.

CODES AND REGULATIONS

General

The DP*HH series heat pumps are designed for 

OUTDOOR USE ONLY. This series is available in cooling 

Capacities of 2, 2 ½, 3, 3 ½, 4 and 5 nominal tons of 

cooling. Optional field installed heat kits are available in 

5,8,10,15 and 20 KW. The units can be easily installed 

in manufactured or modular homes with existing high-

static duct work. The units can also be easily converted 

to accommodate a plenum for normal or low-static 

applications. The DP*C & DP*H series are self contained 

packaged units so the only connections needed for 

installation are the supply and return ducts, the line 

and low voltage wiring and drain connection. Rated 

performance is achieved after 20 hours of operation. Rated 

performance is delivered at the specified airflow. See 

outdoor unit specification sheet for split system models 

or product specification sheet for packaged and light 

commercial models. Specification sheets can be found at 

www.goodmanmfg.com for Goodman® brand products or 

www.amana-hac.com for Amana® brand products. Within 

either website, please select the residential or commercial 

products menu and then select the submenu for the type 

of product to be installed, such as air conditioners or heat 

pumps, to access a list of product pages that each contain 

links to that model’s specification sheet.

EPA Regulations

IMPORTANT: The United States Environmental 

Protection Agency (EPA) has issued various 

regulations regarding the introduction and 

disposal of refrigerants in this unit. Failure 

to follow these regulations may harm the 

environment and can lead to the imposition of 

substantial fines. Because regulations may vary 

due to passage of new laws, we suggest a certified 

technician perform any work done on this unit. 

Should you have any questions please contact the 

local office of the EPA.

National Codes

This product is designed and manufactured to permit  

installation in accordance with National Codes. It is the 

installer’s responsibility to install the product in accordance 

with National Codes and/or prevailing local codes and 

regulations.  

MAJOR COMPONENTS

General

The unit includes a hermetically sealed refrigerating system 

(consisting of a compressor, condenser coil, evaporator 

coil with flowrator), an indoor blower, a condenser fan and 

all necessary internal electrical wiring. The heat pump also 

includes a reversing valve, solenoid, defrost thermostat 

and control and loss of charge protection. The system 

is factory-evacuated, charged and performance tested. 

Refrigerant amount and type are indicated on rating plate.

Summary of Contents for DP5HH2441 Series

Page 1: ...ourself with this Installation Manual Observe all safety warnings During installation or repair caution is to be observed It is your responsibility to install the product safely and to educate the cus...

Page 2: ...24 hours prior to compressor start up to ensure crankcase heater has sufficiently warmed the compressor Compressor damage may occur if this step is not followed Before using this manual check the seri...

Page 3: ...ct work The units can also be easily converted to accommodate a plenum for normal or low static applications The DP C DP H series are self contained packaged units so the only connections needed for i...

Page 4: ...the unit be placed so that condenser air discharge does not blow toward windows less than 25 feet away The unit should be set on a solid level foundation preferably a concrete slab at least 4 inches...

Page 5: ...rter Your distributor has a factory designed square to round converter transition The model s of these kits are as follows Small Chassis 25 SQRPCH101 Medium Chassis 27 5 SQRPCH102 Large and Extra Larg...

Page 6: ...ty of sufficient power to operate the unit The voltage frequency and phase at the power supply should be checked to make sure it corresponds to the unit s RATED VOLTAGE REQUIREMENT Install a branch ci...

Page 7: ...gth of the run can be determined from Table 4 using the circuit ampacity found on the unit rating plate From the unit disconnect to unit the smallest wire size allowable in Table 4 may be used for the...

Page 8: ...ndoor return air until the unit trips 13 If unit operates properly in the heating cycle raise the temperature setting until the heating second stage makes contact Supplemental resistance heat if insta...

Page 9: ...used to prevent full electric heater operation at varying outdoor ambient 0 F to 45 F They are normally open above their set points and closed below to permit staging of indoor supplement heater oper...

Page 10: ...ostat calls for heat At the end of the timing period the unit s defrost cycle will be initiated provided the sensor remains closed When the sensor opens approximately 60 5 F the defrost cycle is termi...

Page 11: ...ll use the higher speed setting NOTE GPC15 and GPH16 units are rated for a maximum E S P of 0 8 except when using a 20kw electric heater The maximum static for 20 kW electric heat is 0 5 E S P When th...

Page 12: ...d small line near liquid line access fitting with adequate contact and insulate for best possible reading 3 Check subcooling and superheat Two stage systems running on low stage with TXV application s...

Page 13: ...clean and sufficient air volume must pass through the indoor coil to prevent excessive discharge pressure and high pressure cut out Outside Air Into Return Duct Do not introduce cold outside air into...

Page 14: ...M 1645 1602 1560 1517 1475 1433 1390 1347 Watts 285 297 309 321 333 346 358 370 CFM 1239 1184 1146 1091 1049 1001 948 890 Watts 152 163 175 184 194 205 220 235 CFM 1837 1789 1748 1706 1665 1623 1577 1...

Page 15: ...ssor stuck grounded or open winding open internal overload b Wait at least 2 hours for overload to reset If still open replace the compressor c Low voltage connection c At compressor terminals voltage...

Page 16: ...minum Indoor Coil Cleaning Qualified Servicer Only This unit is equipped with an aluminum tube evaporator coil The safest way to clean the evaporator coil is to simply flush the coil with water This c...

Page 17: ...Type NG Natural Gas LP Liquid Propane Residential Package Outdoor Section ELECTRICAL Supply Voltage Measure L1 and L2 Voltage L1 L2 Compressor Amps Condenser Fan Amps PRESSURES TEMPERATURES Suction Ci...

Page 18: ...18 THIS PAGE LEFT INTENTIONALLY BLANK...

Page 19: ...19 THIS PAGE LEFT INTENTIONALLY BLANK...

Page 20: ...he feedback page PRODUCT REGISTRATION Thank you for your recent purchase Though not required to get the protection of the standard warranty registering your product is a relatively short process and e...

Reviews: