Thermostat Requirements
DM96SE and DC96SE model furnaces require a single
stage heating thermostat for operation. It is recommended
that a high quality thermostat with a "C" terminal is used to
operate the furnace.
GAS SUPPLY AND PIPING
The furnace rating plate includes the approved furnace gas
input rating and gas types. The furnace must be equipped
to operate on the type of gas applied. This includes any
conversion kits required for alternate fuels and/or high
altitude.
CAUTION
To prevent unreliable operation or equipment damage, the
inlet gas supply pressure must be as specified on the unit
rating plate with all other household gas fired appliances
operating.
Inlet gas supply pressures must be maintained within the
ranges specified below. The supply pressure must be
constant and available with all other household gas fired
appliances operating. The minimum gas supply pressure
must be maintained to prevent unreliable ignition. The
maximum must not be exceeded to prevent unit overfiring.
POSITION
SIDES
REAR
FRONT
BOTTOM
FLUE
TOP
Up
fl
ow
0"
0"
1"
C
0"
1"
Horizontal
6"
0"
1"
C
0"
4"
POSITION
SIDES
REAR
FRONT
BOTTOM
FLUE
TOP
Down
fl
ow
0"
0"
1"
NC
0"
1"
Horizontal
6"
0"
1"
C
0"
4"
DM92SN & DM96SN MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
DC96SN MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
C = Combus
�
ble: if placed on combus
�
ble
fl
oor, the
fl
oor MUST be wood ONLY.
For servicing or cleaning, a 24: front clearance is recommended.
Unit connec
�
ons (electrical,
fl
ue, and drain) may necessitate great clearances than the minimum clearances listed above.
In all cases, accessibility clearance must take precedence over from the enclosure where accessibility clearances are greater.
Approved for line contact in the horizontal posi
�
on.
C = Combus
�
ble: if placed on combus
�
ble
fl
oor, the
fl
oor MUST be wood ONLY.
NC = Non-Combus
�
ble: A combus
�
ble
fl
oor sub-base must be used for installa
�
on on combus
�
ble
fl
ooring.
Notes:
For servicing or cleaning, a 24: front clearance is recommended.
Unit connec
�
ons (electrical,
fl
ue, and drain) may necessitate great clearances than the minimum clearances listed above.
In all cases, accessibility clearance must take precedence over from the enclosure where accessibility clearances are greater.