Airflow Charts - DC96SN
0.6
0.7
0.8
CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM
F01^^ 632 N/A 574 N/A 510 N/A 448 N/A 388 N/A 332 277 234
F02^ 727
48
677
51
623
54
565
60
510
65
455 403 351
F03 878
41
839
42
797
45
751
47
701
51
653 607 561
F04 948
38
910
39
870
41
828
43
785
45
739 693 652
F01^^ 771 N/A 698 N/A 632 N/A 560 N/A 491 N/A 428 372 307
F02^ 1197 45 1150 46 1102 48 1057 50 1014 53
968 926 877
F03 1309 41 1264 42 1224 44 1180 45 1141 47 1098 1058 1018
F04 1138 47 1091 49 1043 51
993
54
949
56
901 853 805
F01^^ 873 N/A 778 N/A 682 N/A 630 N/A 578 N/A 490 419 347
F02^ 1442 49 1386 51 1335 53 1280 56 1221 58 1157 1110 1054
F03 1643 43 1588 45 1534 46 1478 48 1415 50 1357 1299 1246
F04 1600 44 1555 46 1505 47 1460 49 1412 50 1364 1309 1260
F01^^ 1176 N/A 1107 N/A 1037 N/A 969 N/A 891 N/A 825 753 692
F02^ 1773 42 1721 43 1671 44 1621 46 1571 47 1521 1470 1421
F03^^ 1709 43 1658 45 1607 46 1556 48 1503 49 1451 1399 1349
F04 1651 45 1597 46 1542 48 1491 50 1437 52 1384 1332 1278
F01^^ 1187 N/A 1101 N/A 1013 N/A 931 N/A 847 N/A 764 677 604
F02^ 1973 45 1916 46 1864 48 1810 49 1756 51 1702 1650 1590
F03 1918 46 1859 48 1807 49 1748 51 1696 52 1643 1591 1531
F04 1835 48 1776 50 1720 52 1657 54 1602 55 1544 1483 1428
NOTE:
^ DEFAULT & RECOMMENDED
^^ NOT RECOMMENDED FOR HEATING
HEATING AIFLOW
W/W1
W/W1
35-65
W/W1
35-65
MODEL
THERMOSTAT
CALL
TAP #
EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN)
TEMP
RANGE
0.1
0.2
0.3
0.4
0.5
DC96SN0403B*
DC96SN0603B*
45-75
W/W1
40-70
W/W1
40-70
DC96SN0804C*
DC96SN1005C*
DC96SN1205D*