background image

49

WIRING DIAGRAMS

HI

G

VO

LT

A

G

E

!

DI

S

CO

NNE

CT

 AL

PO

W

E

BE

FO

RE

 S

ERV

ICI

NG

 O

INS

TA

LL

IN

G

 T

HI

S

U

N

IT

.  

M

U

LT

IPL

PO

W

ER

 SO

U

R

C

ES 

M

AY 

B

P

R

ESEN

T.

  F

A

IL

U

R

TO

DO

 S

O

 M

AY

 CAUS

PRO

P

ERT

DAM

AG

E,

 P

ERS

O

NAL

 INJ

UR

O

DE

AT

H

.

Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.

CCH

BK

GR

RD

BK

BK

CHR

CHR

2

4

6

8

1

2

3

4

5

6A

7

8

R

XMFR 

- R

XMFR 

- C

C

SPEED UP

EBTDR

G

COM

NC

NO

M1

M2

3A

12

11

10

9

8

7

6

5

4

3

2

1

12

11

10

9

8

7

6

5

4

3

2

1

4

3

2

1

4

3

2

1

9

8

7

6

5

4

3

2

1

BL

BL

6

5

4

3

2

1

6

5

4

3

2

1

RD

CC

PO

W

ER 

AND

 C

ONTR

OL

 W

IR

IN

G

 D

IA

GRA

M

D

B

C0

72

, 3

 P

H

ASE,

 2

-SPD

 B

EL

D

RI

VE

CH

S

THE

+

6A

6B

6B

PLM

PLF

PU
YL

TB1

PLM

PLF

GR

YL

PU

GR

WH

2

TB1

W2

Y1

O

Y2

S2

R

W1

C

S1

G

DH

T1

T2

T3

T4

T5

GY

YL

WH

PU

TB2

B

A

C

D

BL

CC

A1

A2

BL

W

IRE C

OD

E

NO

T

ES

BLACK BLUE

BLUE WITH PINK STRIPE BROW

N

GREE

N

GRAY ORA

NGE

PINK PU

RPLE

R

ED

TAN WHITE YELL

OW

YELL

OW

 W

ITH PINK STRIPE

BK BL BL/PK BR GR GY OR PK PU RD

TN WH

YL YL

/PK

HIG

H VOLTAGE

LOW

 VOLTAGE

OPTI

ONAL 

HIG

H VOLTAGE

OPTI

ONAL LOW V

OLTAGE

C

HASSIS GRO

U

N

D

FIE

LD

W

IRIN

G

FAC

TOR

Y

W

IRIN

G

HIG

H VOLTAGE

LOW

 VOLT

AGE

EART

H G

ROU

N

D

CO

MP

ON

EN

T LE

G

END

RD

RD

BL

GR

YL

WH

PU

BL

YL

EHK

PLF

BR

WH

BR

3

PK

PK

YL

HPS

LPS

PLF

PLM

BL

BL

YL

YL

BL/PK

YL

/PK

YL

/PK

BL/PK

YL

BK

BK

BK

BK

YL

0140L07197-

A

GY

WH

BK

L1

L2

T3

COMP

L3

T1

T2

BK

L3

L1

PB

L1

GND

L2

L3

LINE

VOLTAGE

BK

RD

OR

TR1

CB

GR

BK

RD

OR

RD

L2

4

208-230/460/575V/3PH/60

H

z

FB1

5

BK

RD

OR

COM

F1

F1

F1

BK

OR

GR

M 3~

YL

BK

RD

BKBK

RD

OR

BK

RD

OR

FB2

F2

F2

F2

5

RD

RD

3

CHR

1

0

PK

PK

RD

RD

BL

BL

BC

BLOWER CO

NTA

CTO

R

CB

CI

R

C

UIT BREAKER

CC

COMP

RESSO

CO

NTA

CTO

R

CCH

C

RA

NK

CASE 

HEATE

R

CC

P

COMP

RESSO

R/

COIL PROTE

CTION

CHR

C

RA

NKASE 

HEATE

RELAY

CH

S

C

RA

NK

CASE 

HEATE

R SWITC

H

CM

CO

N

DE

NSE

R MOTOR

COMP

COMP

RESSO

R

EBTD

R

ELECTRO

NIC BLOWER TIME

 DELAY

ECON

ECO

NOMIZE

R

EHK

ELECTRIC 

HEATE

R KIT

ES

EMERGE

N

CY SH

UTDOW

N

FB

FU

SE

 B

LO

C

K

FC

FA

CAPACITO

R

FPS

FREEZE P

ROTECTION SWITC

H

GND

EQUIPMENT G

RO

U

N

D

HPS

HIG

H P

RESS

U

RE SWITC

H

LPS

LOW

 PRESS

U

RE SWITC

H

MAT

MI

XED AIR TEMP.

 SENSO

R

PB

POWER DISTRIB

UTION BLO

CK

PLF

FEMALE PLUG/CO

N

NE

CTO

R

PLM

MALE PLUG/CO

N

NE

CTOR

TB

TERMI

NAL BLOCK

TR

TRA

NS

FORME

R

REP

LACEMENT 

WIR

MU

ST 

BE 

SA

ME 

SIZE

AND TYPE O

F INSUL

ATIO

N AS ORIGINA

L (AT

LE

AS

10

5° 

C). 

US

COPPER 

CONDU

C

TORS

ONLY. USE N.E.C. CLA

SS 

2 WI

R

E F

OR AL

L L

OW

VOL

TAG

E FI

ELD 

CONN

ECTIO

NS.

IF O

PTIO

NAL 

EC

ONOMIZ

ER I

S IN

ST

AL

LED

REMOVE E

CON PLM JUM

PER AN

D PLUG IN

N

EW

 H

A

R

N

ES

S F

R

O

M

 E

C

O

N

O

M

IZ

ER

 K

IT

IF 

O

PTIO

NAL 

EL

ECTRIC 

H

EAT 

IS 

IN

ST

AL

LE

D

PLUG IN N

EW H

ARNESS FROM 

EL

ECT

RIC

HEA

TER 

KIT. 

FOR 

TW

ST

AGE 

HEA

T, 

R

EM

OVE

JUMP

ER.

TR1 

PRIM

ARY 

(HIGH 

VO

LT

AGE)

CONN

ECTIONS:  O

RANGE WIR

E CONNEC

TED

TO 

24

0/

46

0/

57

5V 

TA

AT 

THE 

FAC

TORY 

AN

D

BL

ACK WIR

E T

O COM T

ERMINA

L. FOR 2

08

V

SUP

PLY POW

ER, MOVE O

RANGE WIR

E F

ROM

24

0V 

TA

P T

O T

HE 

20

8V 

TA

P.

FU

SE

 BL

OCKS 

1, 

2, 

ARE 

O

PTIO

NAL

IF O

PTIO

NAL 

SAFE

TY EQ

UIPM

ENT 

SUCH 

AS A

PHA

SE MONIT

OR, FL

OAT 

SWI

TCH O

R SM

OKE

D

ET

EC

TO

R

 IS

 IN

ST

AL

LE

D

, U

N

PL

U

G

 J

U

M

PE

R

PLUG A

ND 

PLUG IN SAFE

TY DEVI

C

E. IF

 MUL

TI

PL

E

SA

FETI

ES

 ARE 

INS

TAL

LED, 

PLUG 

IN 

TH

E

ADDITI

ONAL DE

VIC

ES IN S

ERI

ES. P

LUG IN

JUMP

ER 

PLUG 

AT 

THE 

LA

ST 

SAFETY 

DEVICE

IN

ST

AL

LE

D.

IF A 

THIRD 

PARTY SA

FE

TY DEVICE IS FI

ELD

INST

AL

LED, CU

THE RED WIR

E O

N T

HE JUM

PER

PLUG A

ND WIR

E A 

NORM

AL

LY CL

OSED DRY

CON

TACT IN 

SERIES WI

TH T

HE CU

T WIR

E.

GRAY WIRE IS A 

24 V

AC 

AL

AR

M OU

TPUT 

FR

OM

OPTIO

NAL 

ECON

OMIZ

ER 

CON

TRO

L MODULE.

R

EM

O

VE

 J

U

M

PE

R

 W

IR

IF

 O

PT

IO

N

AL

FR

EE

ZES

TA

IS 

IN

ST

AL

LED.

CHR, C

CH, CH

S A

ND AL

L A

SSOCIAT

ED WI

RING

ARE O

PTIO

NA

L.

FO

R

 D

ET

AI

LE

D

 IN

TE

R

N

AL

 W

IR

IN

G

 A

N

D

TERMINA

TIO

N, REFER T

O T

HE M

O

TOR'

S

NAMEP

LA

TE.

BL

PK

T

HERM

O

S

TA

T FI

ELD

W

IRIN

G

++

1 STA

GE COOLING/HEATING

2 STA

GE COOLING/HEATING

TB1

TSTAT

W

G

R

Y

C

O

WH

GR

PK

YL

BL

OR

W1

W2

G

R

Y1

Y2

C

O

TB1

TSTAT

W1

G

R

Y1

C

O

WH

GR

PK

YL

BL

OR

W1

W2

G

R

Y1

Y2

C

O

BR

W2

PU

Y2

PK

BL

7

ES

ECO

N

FPS

BK

BK

8

RD

GR

PK

WH

CC

P

LOW

  SPEED

HIG

H SPEE

D

GR

BK/12

BK/11

BK/13

M 3~

BM

BC2

L1

T3

T2

T1

L3

L2

L1

T3

T2

T1

L3

L2

WH

BL

OR

BK

RD

YL

WH

BL

OR

BK
RD
OR

RD

RD

PK

BL

CS

V1

V2

PK

PU

YL

R1

R2

t = 180s

Y1

Y2

TON

BL

YL

YL

BL

BL

PK

GR

BR2

1

0

YL

BR1

1

0

BR2

2

4

BR2

3

4

BR1

4

2

BR1

4

3

BC1

A1

A2

BR

BC2

A1

A2

BK

GR

BL

BL

BL

BL

GY

YL

GY

BL

YL

GR

BL

YL

WH

GR

BL

RD

PK

YL

PU

WH

9

9

9

BC1

PU

WH

YL

BL

BL

PU

BL

RD

FC

CM

GR

BR

BK

PU

BR

PU

BK

PU

BK

PLF

PLM

BK

PU

2

1

M 1~

2

1

BK

RD

OR

CM

MAT

PLF

BK

BK

10

10

2

1

Summary of Contents for DBC0363B Series

Page 1: ...t specified in this manual only licensed personnel should servise the equipment Improper installation adjustment servicing or repair of the equipment specified in this manual or attempting to install...

Page 2: ...ce CAUTION Sheet metal parts screws clips and similar items inherently have sharp edges and it is necessary that the installer and service personnel exercise caution WARNING Do not connect to or use a...

Page 3: ...ld also where applicable follow information presented in accepted industry guides such as the ASHRAE Handbooks The manufacturer assumes no responsibility for equipment installed in violation of any co...

Page 4: ...Installations Only To avoid possible property damage or personal injury the roof must have sufficient structural strength to carry the weight of the unit s and snow or water loads as required by local...

Page 5: ...ntenance and proper unit operation A clearance of 48 is recommended on all sides of the unit to facilitate possible parts replacement to allow service access and to insure proper ventilation and conde...

Page 6: ...to protect unit base frame from fork lift damage Removal is accomplished by extracting the sheet metal retainers and pulling the struts through the base of the unit Refer to rigging label on the unit...

Page 7: ...MUM OVERCURRENT DEVICE SIZE SHOWN ON UNIT DATA PLATE All line voltage connections must be made through weatherproof fittings All exterior power supply and ground wiring must be in approved weatherproo...

Page 8: ...f unit due to operation on improper line voltage or with excessive phase unbalance constitutes product abuse and is not covered by the warranty It may cause severe damage to the unit s electrical comp...

Page 9: ...may be required before entering thermostat sub base NOTE Refer to unit wiring diagrams for thermostat or remote sensor connections CIRCULATING AIR AND FILTERS Ductwork The supply duct from the unit t...

Page 10: ...d for temporary heating or cooling inspect the coils fans and motors for unacceptable levels of construction dust and dirt and install new filters Contractor Responsibility The installing contractor m...

Page 11: ...it is best to have a variable pitched motor sheave for the purpose of airflow balancing but once the balance has been achieved fixed sheaves maintain alignment and minimize vibration more effectively...

Page 12: ...ck that the compressor is operating correctly The scroll compressors in these units MUST operate in the proper rotation To ensure the compressors are operating in the correct direction check the compr...

Page 13: ...e by redirecting refrigerant flow through the refrigerant circuit external to the compressor This is accomplished by the reversing valve Hot discharge vapor from the compressor is directed to the indo...

Page 14: ...ilters should be cleaned or replaced These few steps will help to keep the product up time to a maximum The Service section that follows should help in identifying problems if the unit does not operat...

Page 15: ...STATIC BELT DRIVE DOWNSHOT ESP In H2 O TURNS OPEN 0 1 2 3 4 5 CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP 0 7 1481 1020 0 57 0 8 1370 1020 0 53 0 9 1434 1080 0 62 1247 102...

Page 16: ...250 950 0 42 989 885 0 30 DBC036 C HIGH STATIC BELT DRIVE HORIZONTAL ESP In H2 O TURNS OPEN 0 1 2 3 4 5 CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP 0 8 1539 1020 0 59 0 9 1...

Page 17: ...FM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP 0 6 1996 1200 1 05 1872 1135 0 88 1741 1075 0 74 0 7 1922 1200 1 01 1790 1135 0 84 1650 1075 0 70 0 8 1985 1265 1 17 1845 1200 0 97 1703 1135...

Page 18: ...HIGH STATIC BELT DRIVE HORIZONTAL ESP In H2 O TURNS OPEN 0 1 2 3 4 5 CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP 0 6 1895 1075 0 81 0 7 1958 1135 0 93 1802 1075 0 76 0 8 18...

Page 19: ...BELT DRIVE DOWNSHOT ESP In H2 O TURNS OPEN 0 1 2 3 4 5 CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP 0 6 2237 1245 1 27 2072 1175 1 03 0 7 2333 1315 1 48 2164 1245 1 23 1990 1175 0 99 0...

Page 20: ...65 DBC060 C HIGH STATIC BELT DRIVE HORIZONTAL ESP In H2 O TURNS OPEN 0 1 2 3 4 5 CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP 0 6 2394 1245 1 37 2239 1175 1 12 0 7 2320 1245...

Page 21: ...175 1 05 1900 1110 0 86 DBC072 S HIGH STATIC BELT DRIVE DOWNSHOT ESP In H2 O TURNS OPEN 0 1 2 3 4 5 CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP 0 6 2630 1385 1 88 2492 1315...

Page 22: ...1110 0 84 DBC072 S HIGH STATIC BELT DRIVE HORIZONTAL ESP In H2 O TURNS OPEN 0 1 2 3 4 5 CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP 0 6 2655 1385 1 90 2520 1315 1 62 2369 1...

Page 23: ...5 0 26 DBH036 C HIGH STATIC BELT DRIVE DOWNSHOT ESP In H2 O TURNS OPEN 0 1 2 3 4 5 CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP 0 8 1587 1020 0 61 0 9 1456 1020 0 56 1 0 151...

Page 24: ...0 35 Note VL34 and AK61 pulleys used on standard static unit DBH036 C HIGH STATIC BELT DRIVE HORIZONTAL ESP In H2 O TURNS OPEN 0 1 2 3 4 5 CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP C...

Page 25: ...O TURNS OPEN 0 1 2 3 4 5 CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP 0 6 2003 1075 0 85 0 7 1898 1075 0 81 0 8 1936 1135 0 91 1788 1075 0 76 0 9 1979 1200 1 05 1833 1135 0...

Page 26: ...RNS OPEN 0 1 2 3 4 5 CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP 0 6 1885 1075 0 80 0 7 1955 1135 0 92 1791 1075 0 76 0 8 1865 1135 0 88 1691 1075 0 72 0 9 1948 1200 1 03 1...

Page 27: ...H2 O TURNS OPEN 0 1 2 3 4 5 CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP 0 6 2397 1310 1 53 2278 1245 1 31 2145 1180 1 10 2003 1115 0 92 0 7 2334 1310 1 48 2208 1245 1 26 2...

Page 28: ...TURNS OPEN 0 1 2 3 4 5 CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP 0 6 2421 1310 1 55 2297 1245 1 32 2161 1180 1 11 2016 1115 0 92 0 7 2357 1310 1 50 2227 1245 1 27 2083 11...

Page 29: ...7 4 17 4 25 25 9 6 8 7 27 0 26 1 35 35 1 7 1 5 19 1 18 9 25 25 9 6 8 7 1 7 1 5 28 7 27 6 35 35 EH B 3S05 3 76 5 00 10 4 12 0 17 4 19 3 25 25 9 6 8 7 29 3 30 2 35 35 1 7 1 5 19 4 21 2 25 25 9 6 8 7 1 7...

Page 30: ...30 9 6 8 7 30 8 29 9 40 40 1 7 1 5 22 9 22 7 30 30 9 6 8 7 1 7 1 5 32 5 31 4 40 40 EH B 3S05 3 76 5 00 10 4 12 0 21 2 21 2 30 30 9 6 8 7 30 8 30 2 40 40 1 7 1 5 22 9 22 7 30 30 9 6 8 7 1 7 1 5 32 5 3...

Page 31: ...7 1 5 55 0 62 0 60 70 9 6 8 7 1 7 1 5 67 0 72 9 70 80 EH B 3S20 15 0 19 9 41 5 47 9 57 9 65 8 60 70 9 6 8 7 69 9 76 7 70 80 1 7 1 5 60 0 67 7 60 70 9 6 8 7 1 7 1 5 72 0 78 6 80 80 DBC0484B 460 3 60 1...

Page 32: ...7B 575 3 60 1 4 36 33 1 0 25 0 55 Belt Drive Standard Static 1 5 2 3 8 3 15 3 5 11 8 15 0 6 8 9 15 3 5 0 6 12 4 15 EH B 7S05 5 4 81 8 89 15 3 5 13 3 15 0 6 9 64 15 3 5 0 6 14 15 EH B 7S10 10 9 62 14 9...

Page 33: ...76 5 00 10 4 12 0 25 1 25 1 40 40 9 6 8 7 34 7 33 8 50 45 1 7 1 5 26 8 26 6 40 40 9 6 8 7 1 7 1 5 36 4 35 3 50 45 EH B 3S10 7 51 10 0 20 8 24 1 30 1 34 1 40 40 9 6 8 7 42 1 44 9 50 45 1 7 1 5 32 2 35...

Page 34: ...5 55 0 62 0 60 70 9 6 8 7 1 7 1 5 67 0 72 9 70 80 EH B 3S20 15 0 19 9 41 5 47 9 57 9 65 8 60 70 9 6 8 7 69 9 76 7 70 80 1 7 1 5 60 0 67 7 60 70 9 6 8 7 1 7 1 5 72 0 78 6 80 80 DBC0604B 460 3 60 1 7 0...

Page 35: ...575 3 60 1 5 13 39 5 1 0 33 0 67 Belt Drive Standard Static 1 1 2 8 28 15 3 5 11 8 15 0 6 8 88 15 3 5 0 6 12 4 15 EH B 7S05 5 4 81 8 28 15 3 5 11 9 15 0 6 8 88 15 3 5 0 6 12 6 15 EH B 7S10 10 9 62 13...

Page 36: ...1 5 31 7 31 5 45 45 9 6 8 7 1 7 1 5 41 3 40 2 50 50 EH B 3S10 7 51 10 0 20 8 24 1 33 6 37 6 45 45 9 6 8 7 45 6 48 4 50 50 1 7 1 5 35 7 39 4 45 45 9 6 8 7 1 7 1 5 47 7 50 3 50 60 EH B 3S15 11 3 15 0 3...

Page 37: ...6 8 7 71 4 78 2 80 80 1 7 1 5 61 5 69 2 70 70 9 6 8 7 1 7 1 5 73 5 80 1 80 90 EH B 3S30 21 6 28 8 60 0 69 3 82 6 94 1 90 100 9 6 8 7 94 6 105 100 110 1 7 1 5 84 7 96 0 90 100 9 6 8 7 1 7 1 5 96 7 107...

Page 38: ...0 DBC0727S 575 3 60 1 6 35 55 3 1 0 33 0 67 2 speed Belt Drive High Static 2 2 4 11 15 3 5 14 5 20 0 6 11 6 15 3 5 0 6 15 1 20 EH B 7S05 5 4 81 11 15 3 5 14 5 20 0 6 11 6 15 3 5 0 6 15 1 20 EH B 7S10...

Page 39: ...45 EH B 3S10 7 51 10 0 20 8 24 1 43 5 47 5 45 50 9 6 8 7 53 1 56 2 60 60 1 7 1 5 45 2 49 0 50 50 9 6 8 7 1 7 1 5 54 8 57 7 60 60 EH B 3S15 11 3 15 0 31 3 36 1 56 5 62 5 60 70 9 6 8 7 66 1 71 2 70 80...

Page 40: ...H0367B 575 3 60 1 3 78 36 5 1 0 17 0 39 Belt Drive Standard Static 1 5 2 3 7 42 15 3 5 10 9 15 0 6 8 02 15 3 5 0 6 11 5 15 EH B 7S05 5 4 81 13 4 15 3 5 16 9 20 0 6 14 15 3 5 0 6 17 5 20 EH B 7S10 10 9...

Page 41: ...37 5 43 3 68 1 75 4 70 80 9 6 8 7 77 7 84 1 80 90 1 7 1 5 69 8 76 9 70 80 9 6 8 7 1 7 1 5 79 4 85 6 80 90 EH B 3S20 15 0 19 9 41 5 47 9 73 1 81 1 80 90 9 6 8 7 82 7 89 8 90 90 1 7 1 5 74 8 82 6 80 90...

Page 42: ...3 29 3 30 0 5 25 5 30 4 3 0 5 29 8 30 EH B 4S15 15 18 32 6 35 4 3 36 9 40 0 5 33 1 35 4 3 0 5 37 4 40 EH B 4S18 18 21 7 37 1 40 4 3 41 4 45 0 5 37 6 40 4 3 0 5 41 9 45 EH B 4S20 20 24 1 40 1 45 4 3 44...

Page 43: ...3 5 23 8 25 0 6 20 9 25 3 5 0 6 24 4 25 EH B 7S15 15 14 4 26 3 30 3 5 29 8 30 0 6 26 9 30 3 5 0 6 30 4 35 EH B 7S18 18 17 3 29 9 30 3 5 33 4 35 0 6 30 5 35 3 5 0 6 34 35 EH B 7S20 20 19 2 32 4 35 3 5...

Page 44: ...7 5 43 3 72 3 79 5 80 80 9 6 8 7 81 9 88 2 90 90 1 7 1 5 74 0 81 0 80 90 9 6 8 7 1 7 1 5 83 6 89 7 90 90 EH B 3S20 15 0 19 9 41 5 47 9 77 2 85 2 80 90 9 6 8 7 86 8 93 9 90 100 1 7 1 5 78 9 86 7 80 90...

Page 45: ...4 3 30 7 35 0 5 26 9 30 4 3 0 5 31 2 35 EH B 4S15 15 18 34 35 4 3 38 3 40 0 5 34 5 35 4 3 0 5 38 8 40 EH B 4S18 18 21 7 38 5 40 4 3 42 8 45 0 5 39 40 4 3 0 5 43 3 45 EH B 4S20 20 24 1 41 5 45 4 3 45...

Page 46: ...4 25 0 6 21 1 25 3 5 0 6 24 6 25 EH B 7S15 15 14 4 26 6 30 3 5 30 1 35 0 6 27 2 30 3 5 0 6 30 7 35 EH B 7S18 18 17 3 30 2 35 3 5 33 7 35 0 6 30 8 35 3 5 0 6 34 3 35 EH B 7S20 20 19 2 32 6 35 3 5 36 1...

Page 47: ...THRU THE BASE UTILITIES RETURN 11 X 25 SUPPLY 12 X 17 Horizontal Discharge Vertical Discharge NOTE Refer to IOD 7082 included in the literature pack for installing horizontal duct covers 48 5 16 74 A...

Page 48: ...975 X X X DBC048 1300 X X X X X DBC060 1625 X X X X X DBC072 1950 X X X X X X DBH036 975 X X X DBH048 1300 X X X X X DBH060 1625 X X X X X Note Adjust the pulley setting as needed to achieve the mini...

Page 49: ...NSOR PB POWER DISTRIBUTION BLOCK PLF FEMALE PLUG CONNECTOR PLM MALE PLUG CONNECTOR TB TERMINAL BLOCK TR TRANSFORMER REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE OF INSULATION AS ORIGINAL AT LEAST 105 C...

Page 50: ...E PU BR BK PU BR BK RD OR BK RD OR BK RD YL L2 208 230 460 575V 3PH 60Hz FB1 F1 F1 F1 5 BK PU BK PLF PLM CM BK BK RD OR POWER AND CONTROLS WIRING DIAGRAM DBC036 060 3 PHASE 1 SPD BELT DRIVE 2 1 2 1 GR...

Page 51: ...P FUSE BLOCKS 1 2 3 ARE OPTIONAL IF OPTIONAL SAFETY EQUIPMENT SUCH AS A PHASE MONITOR FLOAT SWITCH OR SMOKE DETECTOR IS INSTALLED UNPLUG JUMPER PLUG AND PLUG IN SAFETY DEVICE IF MULTIPLE SAFETIES ARE...

Page 52: ...52...

Page 53: ...53...

Page 54: ...2020 19001 Kermier Rd Waller TX 77484 www daikincomfort com CUSTOMER FEEDBACK Daikin is very interested in all product comments Please fill out the feedback form on the following link https daikincomf...

Reviews: