background image

Table of contents

Installation manual

3

ATXM20~50+FTXM20~71N2V1B
Daikin room air conditioner
3P482320-8K – 2018.09

Table of contents

1 About the documentation

3

1.1

About this document..................................................................

3

2 About the box

3

2.1

Indoor unit .................................................................................

3

2.1.1

To remove the accessories from the indoor unit.........

3

3 About the unit

3

4 Preparation

4

4.1

Preparing the installation site ....................................................

4

4.1.1

Installation site requirements of the indoor unit ..........

4

5 Installation

4

5.1

Opening the indoor unit .............................................................

4

5.1.1

To remove the front panel...........................................

4

5.1.2

To re-install the front panel .........................................

4

5.1.3

To open the service cover...........................................

4

5.1.4

To remove the front grille ............................................

4

5.1.5

To re-install the front grille ..........................................

5

5.2

Installing the indoor unit ............................................................

5

5.2.1

To install the mounting plate .......................................

5

5.2.2

To drill a wall hole .......................................................

6

5.2.3

To remove the pipe port cover ....................................

6

5.2.4

To provide drainage ....................................................

6

5.3

Connecting the refrigerant piping ..............................................

7

5.3.1

To connect the refrigerant piping to the indoor unit ....

7

5.4

Connecting the electrical wiring.................................................

7

5.4.1

To connect the electrical wiring on the indoor unit......

8

5.5

Finishing the indoor unit installation ..........................................

8

5.5.1

To insulate the drain piping, refrigerant piping and
interconnection cable ..................................................

8

5.5.2

To pass the pipes through the wall hole .....................

8

5.5.3

To fix the unit on the mounting plate...........................

9

5.6

Wireless LAN adapter ...............................................................

9

5.6.1

About the wireless LAN adapter .................................

9

5.6.2

To install the wireless LAN adapter ............................

9

6 Commissioning

11

6.1

Checklist before commissioning ................................................

11

6.2

To perform a test run .................................................................

11

6.2.1

To perform a test run using the user interface ............ 11

7 Disposal

11

8 Technical data

12

8.1

Wiring diagram ..........................................................................

12

1

About the documentation

1.1

About this document

INFORMATION

Make sure that the user has the printed documentation and
ask him/her to keep it for future reference.

Target audience

Authorised installers

INFORMATION

This appliance is intended to be used by expert or trained
users  in  shops,  in  light  industry,  and  on  farms,  or  for
commercial and household use by lay persons.

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety instructions that you MUST read before installing

▪ Format: Paper (in the box of the indoor unit)

Indoor unit installation manual:

▪ Installation instructions

▪ Format: Paper (in the box of the indoor unit)

Installer reference guide:

▪ Preparation of the installation, good practices, reference data,…

▪ Format:  Digital  files  on 

http://www.daikineurope.com/support-

and-manuals/product-information/

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.

The original documentation is written in English. All other languages
are translations.

Technical engineering data

▪ A 

subset

  of  the  latest  technical  data  is  available  on  the  regional

Daikin website (publicly accessible).

▪ The 

full  set

  of  latest  technical  data  is  available  on  the  Daikin

extranet (authentication required).

2

About the box

2.1

Indoor unit

2.1.1

To remove the accessories from the
indoor unit

1

Remove the accessories located at the bottom of the package.

f

e1

d

e2

b

a

c

g h

i

j

a

Installation manual

b

Operation manual

c

General safety precautions

d

Wireless LAN adapter (may NOT be available in some
countries)

e1

Class 15~42

: Titanium apatite deodorizing filter (without

frame)

e2

Class

 

50~71:

 Titanium apatite deodorizing filters (with

frame)

f

Indoor unit fixing screw (M4×12L). Refer to 

"5.5.3 To fix the

unit on the mounting plate" on page 9

.

g

Dry battery AAA.LR03 (alkaline) for user interface

h

User interface holder

i

User interface

j

Mounting plate

3

About the unit

WARNING: FLAMMABLE MATERIAL

The refrigerant inside this unit is mildly flammable.

Summary of Contents for CTXM15N2V1B

Page 1: ...in room air conditioner English Installation manual Daikin room air conditioner CTXM15N2V1B ATXM20N2V1B ATXM25N2V1B ATXM35N2V1B ATXM50N2V1B FTXM20N2V1B FTXM25N2V1B FTXM35N2V1B FTXM42N2V1B FTXM50N2V1B...

Page 2: ...sau alt e document e normativ e cu condi ia ca acestea s fie utilizate n conformitate cu instruc iunile noastre skladni z naslednjimi standardi in drugimi normativi pod pogojem da se uporabljajo v sk...

Page 3: ...erence Target audience Authorised installers INFORMATION This appliance is intended to be used by expert or trained users in shops in light industry and on farms or for commercial and household use by...

Page 4: ...allation 5 1 Opening the indoor unit 5 1 1 To remove the front panel 1 Hold the front panel by the panel tabs on both sides and open it a a Panel tabs 2 Remove the front panel by sliding it to the lef...

Page 5: ...Finish the installation by securing the mounting plate on the wall using M4 25L screws field supply Class 15 42 Class 50 71 INFORMATION The removed pipe port cover can be kept in the mounting plate po...

Page 6: ...over as this would damage the front grille 5 2 4 To provide drainage Make sure condensation water can be evacuated properly This involves General guidelines Connecting the drain piping to the indoor u...

Page 7: ...drain leakage from the plug a a 4 mm hexagonal wrench 3 Insert the drain hose on the left side and do not forget to tighten it with the fixing screw otherwise water leakage may occur a b a b a Insulat...

Page 8: ...part from each other Transmission wiring and power supply wiring may cross but may NOT run parallel In order to avoid any electrical interference the distance between both wirings should ALWAYS be at...

Page 9: ...the definition of Directive 2014 53 EU INFORMATION Install the wireless LAN adapter after finishing the indoor unit installation Refer to 5 6 2 To install the wireless LAN adapter on page 9 Basic par...

Page 10: ...ssory 2 To place the wireless LAN adapter into the unit For class 15 42 1 Place the wireless LAN adapter against the hooks 2 Lock the adapter by pressing it down 3 To remove the adapter perform the in...

Page 11: ...ts in the switch box The insulation resistance of the compressor is OK There are NO damaged components or squeezed pipes on the inside of the indoor and outdoor units There are NO refrigerant leaks Th...

Page 12: ...CH E H HEATER F U FU FOR CHARACTERISTICS FUSE REFER TO PCB INSIDE YOUR UNIT FG CONNECTOR FRAME GROUND H HARNESS H P LED V L PILOT LAMP LIGHT EMITTING DIODE HAP LIGHT EMITTING DIODE SERVICE MONITOR GRE...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...3P482320 8K 2018 09 Copyright 2018 Daikin...