background image

 

13

Error code display

Operation method

A

FTER

-

SALE

 S

ERVICE

Advise the repairer of the following items

Model name

Date of installation

Failure conditions: As precise as possible.

Your address, name, and telephone number

Stock Period of Performance Spare Parts

Performance spare parts are components that are required to
maintain the function of the product.
Daikin has a stock of performance spare parts for the air conditioner
for nine years after the stoppage of producing the air conditioner.

Rough Standards for Part Maintenance Frequency

For details, contact your Daikin dealer. Furthermore, the overhauling
or internal cleaning of the product conducted by repairers other than
those authorized by Daikin may not be within the scope of Daikin’s
product warranty term.

Inquiry 

Contact your Daikin dealer for after-sale services.

D

ISPOSAL

 

REQUIREMENTS

For batteries, a chemical symbol can be printed
beneath the symbol. This chemical symbol means
that the battery contains a heavy metal above a
certain concentration. Possible chemical symbols are:

Pb: lead (>0.004%)

Do not try to dismantle the system yourself: the dismantling of the
product, treatment of the refrigerant, of oil and of other parts must be
done by a qualified installer in accordance with relevant local and
national legislation.

Units and waste batteries must be treated at a specialized treatment
facility for re-use, recycling and recovery.

By ensuring correct disposal, you will help to prevent potential
negative consequences for the environment and human health.

Please contact the installer or local authority for more information.

1

If an error occurs, either one of the following items
will blink in the basic screen.

"Error: Push Menu Button."

* The operation indicator will blink.

"Warning: Push Menu Button."

* The operation indicator will not blink

.

Press Menu/Enter button.

2

The error code blinks and the contact address and model
name will appear.

Notify your Daikin dealer of the Error code and Model name.

Do not disassemble, modify, or repair the unit.

Doing so may result in electric shocks or fire.
Contact your Daikin dealer.

Do not relocate or reinstall by yourself.

Improper installation may result in electric shocks or
fire.
Contact your Daikin dealer.

Beware of fire in case of refrigerant leakage.

If the air conditioner is not operating correctly, i.e. not
generating cool or warm air, refrigerant leakage could
be the cause. Contact your Daikin dealer for
assistance. The refrigerant within the air conditioner is
safe and normally does not leak. However, in the
event of a leakage, contact with a naked burner,
heater or cooker may result in generation of noxious
gas. Do not use the air conditioner any longer until a
qualified service person confirms that the leakage has
been repaired. 

Cool

Return

Setting

Set to

Cool

28

°C

Error : Press Menu Button

Operation

 lamp

Return

Error code:A1

Indoor Model 

–––/000

Outdoor Model  –––/000

Contact Info
0123–4567–8900

Main part name

Inspection period

Filter

1year

NOTE

This table shows main parts. For details, refer to
the maintenance inspection contract.

The replacement frequency depends on condition
of the filter during yearly maintenance. If the dust
become impossible to clean, replace the filter.

Regular inspection is required, depending on the
installation environment.

4PEN470901-1B.book  Page 13  Thursday, September 7, 2017  3:17 PM

Summary of Contents for BAE20A102

Page 1: ...INSTALLATION AND OPERATION MANUAL BAE20A62 BAE20A82 BAE20A102 Auto Cleaning option kit...

Page 2: ...300 1 2 3 4 5 6 7 8 1 1 3 4 5 2 2 2 1 4 5 3 1 2 3 4 5 5 1 2 4 3 4 5 6 7 2 1 3 X70A X13A X1A X39A 1 2 3 4 5 6...

Page 3: ...e made by children without supervision This appliance is intended to be used by expert or trained users in shops in light industry and on farms or for commercial and household use by lay persons Sound...

Page 4: ...of the possibilities listed below 1 Factory installed hangers For a different way of installation the factory set hangers should be repositioned by an authorized installer 1 Remove 3 screws 2 Change...

Page 5: ...ounded head accessories Refer to figure 6 8 Connect the Auto Cleaning option kit with indoor unit using a wire harness accessories according to figure 7 and according to chapter Electric wiring work 9...

Page 6: ...ion of the indoor unit is finished The test operation of the Auto Cleaning option kit is not possible while the indoor unit is in operation Check that the Switch box lids of the indoor unit outdoor un...

Page 7: ...e interior 1 Remove protection net 2 Clean interior of the casing by vacuum cleaner or wet cloth 3 Perform a test operation 4 Use vacuum cleaner to remove remaining dirt from the dust box When trolley...

Page 8: ...DIP SWITCH R T THERMISTOR E H HEATER RC RECEIVER F U FU FOR CHARACTERISTICS REFER TOPCBINSIDE YOUR UNIT FUSE S C LIMIT SWITCH FG CONNECTOR FRAMEGROUND S L FLOAT SWITCH H HARNESS S NPH PRESSURESENSOR H...

Page 9: ...e will highlight The highlighted items will scroll continuously when the button is kept pressed Used to change the item selected 5 Down button Used to lower the set temperature The next items on the l...

Page 10: ...ttings are made NOTE The correct clock settings are necessary The product will perform filter auto cleaning from 12 00 to 15 00 as factory default if the period for filter auto cleaning is not specifi...

Page 11: ...ssage Set clock from menu appears make clock settings again so that the filter auto cleaning will be performed during the designated period CLOCK CALENDAR Setting the clock Operation method Operation...

Page 12: ...0 Day 07 Thursday 12 00 Return Setting Date Time Year 2011 Month 10 Day 07 Thursday 12 00 Return Setting Date Time Year 2011 Month 10 Day 07 Thursday 12 21 Return Setting Save the settings Date Time Y...

Page 13: ...east 10 seconds While vacuuming the dust take away the hose and put it back several times NOTE Dust collection with a vacuum cleaner is not possible during filter auto cleaning Make sure that is not d...

Page 14: ...confirm it on the remote controller See page 12 The dust collection sign appears soon after the dust is vacuumed Check the dust box cleaning interval Set preferred timing The product does not run acc...

Page 15: ...contact the installer or local authority for more information 1 If an error occurs either one of the following items will blink in the basic screen Error Push Menu Button The operation indicator will...

Page 16: ...4P470901 1B 2017 09 Copyright 2017 Daikin...

Reviews: