background image

 

12

Resetting dust collection sign

Operation method

T

ROUBLESHOOTING

The following symptoms are not signs of malfunctions.

* The factory setting will not allow the indicator to flash green.

Check before requesting servicing.

If the product is still not in good condition after checking the above, contact your
Daikin dealer. The customer must not attempt to repair the product.

Contact your Daikin in the following cases

1

When the time for collecting dust from the dust box
comes, collection sign "

" will appear alternately

on the lower part of the basic screen.

At the time of this state, press the Menu/Enter button
on the basic screen. 

2

After vacuuming the dust in the dust box, press 
buttons on the collection confirmation screen and
select 

Yes

 

Press the Menu/Enter button to reset the dust
collection sign.

Symptom

Probable cause

Slight clicking noise is 
generated.

The "

" is 

displayed or the 
indicator on the panel is 
flashing green (*).

The driving sound of 
trolleys.

Scorching noise is 
generated.

The driving sound of 
the brush.

The air conditioning operation of the product stops 
temporarily.

The dust box is full, and 
filter auto cleaning is 
unavailable.

Symptom

Probable cause

Remedy

Dust sticks to the air 
filter (dust falls).

The room has a large 
quantity of dust 
temporarily as a result 
of the cleaning of the 
room.

Stop the operation of 
the air conditioner until 
the cleaning of the 
room is finished. If 
necessary, clean the air 
filter.

The dust box is full.

Vacuum the dust. (See 
page 11.)

The display "AH" will 
appear on screen of the 
remote controller and 
the operation lamp will 
flash.

The dust box is full.

Vacuum the dust and 
confirm it on the remote 
controller.
(See page 12.)

The dust collection sign 
appears soon after the 
dust is vacuumed.

Check the dust box 
cleaning interval.

Set preferred timing.

The product does not 
run according to the 
timer settings.

Are the settings in the 
remote controller 
wrong?

Make settings in the 
remote controller again.

Auto

28

°C

20

°C

Colect dust

Set to

Cool

Heat

Return

Setting

Was dust collected?

Dust Collection Method

Yes

No

Cool

Set to

Cool

28

°C

The error code AH-14 
will appear on screen of 
the remote controller.

One or both trolleys did 
not arrive from one to 
other side in time limit 
of 300 seconds.

Check if 4 screws 
holding the trolleys and 
carton from under and 
behind the trolleys are 
removed.

Stop cleaning
operation, turn the
indoor unit power off,
wait 10 seconds. Turn
indoor unit power on
and check whether
there aren’t any objects
blocking the trolley to
reach the limit switch.

When the air conditioner is malfunctioning (e.g.,
giving off a burning odor), stop the air conditioner
and turn off power.

Continued operation under such circumstances may
result in failure, electric shocks, or fire. 

Symptom

Measures to be taken 

before requesting 

servicing

The fuse blows out or safety devices, such 
as the power circuit breaker and earth 
leakage circuit breaker trip often.

Do not turn ON the 
product.

The operation of the buttons on the remote 
controller is inaccurate.

Turn OFF the product.

There are other malfunctions or faults.

Stop operation of the 
product.

Either one of the following messages 
flashes on the basic screen of the remote 
controller.
"Error: Push Menu Button."

The operation indicator will blink.

"Warning: Push

 

Menu Button."

* The operation indicator will not blink.

Check the malfunction 
codes. (see below)

Symptom

Probable cause

Remedy

Cool

Return

Setting

Set to

Cool

28

°C

Error : Press Menu Button

4PEN470901-1B.book  Page 12  Thursday, September 7, 2017  3:17 PM

Summary of Contents for BAE20A102

Page 1: ...INSTALLATION AND OPERATION MANUAL BAE20A62 BAE20A82 BAE20A102 Auto Cleaning option kit...

Page 2: ...300 1 2 3 4 5 6 7 8 1 1 3 4 5 2 2 2 1 4 5 3 1 2 3 4 5 5 1 2 4 3 4 5 6 7 2 1 3 X70A X13A X1A X39A 1 2 3 4 5 6...

Page 3: ...e made by children without supervision This appliance is intended to be used by expert or trained users in shops in light industry and on farms or for commercial and household use by lay persons Sound...

Page 4: ...of the possibilities listed below 1 Factory installed hangers For a different way of installation the factory set hangers should be repositioned by an authorized installer 1 Remove 3 screws 2 Change...

Page 5: ...ounded head accessories Refer to figure 6 8 Connect the Auto Cleaning option kit with indoor unit using a wire harness accessories according to figure 7 and according to chapter Electric wiring work 9...

Page 6: ...ion of the indoor unit is finished The test operation of the Auto Cleaning option kit is not possible while the indoor unit is in operation Check that the Switch box lids of the indoor unit outdoor un...

Page 7: ...e interior 1 Remove protection net 2 Clean interior of the casing by vacuum cleaner or wet cloth 3 Perform a test operation 4 Use vacuum cleaner to remove remaining dirt from the dust box When trolley...

Page 8: ...DIP SWITCH R T THERMISTOR E H HEATER RC RECEIVER F U FU FOR CHARACTERISTICS REFER TOPCBINSIDE YOUR UNIT FUSE S C LIMIT SWITCH FG CONNECTOR FRAMEGROUND S L FLOAT SWITCH H HARNESS S NPH PRESSURESENSOR H...

Page 9: ...e will highlight The highlighted items will scroll continuously when the button is kept pressed Used to change the item selected 5 Down button Used to lower the set temperature The next items on the l...

Page 10: ...ttings are made NOTE The correct clock settings are necessary The product will perform filter auto cleaning from 12 00 to 15 00 as factory default if the period for filter auto cleaning is not specifi...

Page 11: ...ssage Set clock from menu appears make clock settings again so that the filter auto cleaning will be performed during the designated period CLOCK CALENDAR Setting the clock Operation method Operation...

Page 12: ...0 Day 07 Thursday 12 00 Return Setting Date Time Year 2011 Month 10 Day 07 Thursday 12 00 Return Setting Date Time Year 2011 Month 10 Day 07 Thursday 12 21 Return Setting Save the settings Date Time Y...

Page 13: ...east 10 seconds While vacuuming the dust take away the hose and put it back several times NOTE Dust collection with a vacuum cleaner is not possible during filter auto cleaning Make sure that is not d...

Page 14: ...confirm it on the remote controller See page 12 The dust collection sign appears soon after the dust is vacuumed Check the dust box cleaning interval Set preferred timing The product does not run acc...

Page 15: ...contact the installer or local authority for more information 1 If an error occurs either one of the following items will blink in the basic screen Error Push Menu Button The operation indicator will...

Page 16: ...4P470901 1B 2017 09 Copyright 2017 Daikin...

Reviews: