Indoor Unit Installation
WARNING
• Only use accessories, optional equipment and spare parts made or approved by DAIKIN.
• Installation shall be done by an installer, the choice of materials and installation shall comply with the applicable legislation.
In Europe, the EN378 is the applicable standard that shall be used.
1.
Installing the mounting plate
• The mounting plate should be installed on a wall which can support the weight of the indoor unit.
1) Temporarily secure the mounting plate to the wall, make sure that the panel is completely level, and mark the boring points
on the wall.
2) Secure the mounting plate to the wall with screws.
Recommended mounting plate retention spots and dimensions
337
770
A
A
285
44.5
170
48
48
44.5
116.5
117
337
50
213
237
170
Place the pipe port cover
in this pocket.
Place a leveler
on these tabs.
Recommended mounting plate
retention spots (7 spots in all)
Through-the-wall
hole Ø65
Drain hose position
Gas pipe end
Liquid pipe end
Use a tape measure
as shown.
Position the end of
the tape measure at .
990
295
170
60
170
44.5
44.5
122
121.5
56.5
56.5
404
475
The removed pipe
port cover can be
kept in the mounting
plate pocket.
Mounting
plate
Removed pipe
port cover
A
Class 20/25/35:
Class 50/60/71:
PIPING HOLE
CENTER:170mm
TO THE LEFT
PIPING HOLE
CENTER:170mm
TO THE LEFT
Place a leveler
on these tabs.
Gas pipe end
Liquid pipe end
Through-the-wall
hole Ø65
Drain hose
position
Recommended mounting
plate retention spots
(5 spots in all)
3P393185-3W.book Page 7 Wednesday, January 25, 2017 5:50 PM