![background image](http://html.mh-extra.com/html/daikin/atm09mv2s/atm09mv2s_service-manual_501366020.webp)
Indoor Heat Exchanger
Si041251EC
18
Removal Procedure
4
Unfasten the hook of
the piping fixture at the
back of the indoor unit
and pull out the piping.
5
Slightly widen the
auxiliary piping.
6
Unfasten the upper
hook (left) with a flat
screwdriver.
7
Unfastening the lower
hook (left), hold up the
indoor heat exchanger
by its left side and lift it
up.
When reassembling the
indoor heat exchanger,
make sure that the left
hooks are fastened.
Step
Procedure
Points
Piping fixture
(R4401)
(R17211)
(R17927)
Upper
hook (left)
Lower hook
(left)
(R17928)