![background image](http://html.mh-extra.com/html/daikin/atm09mv2s/atm09mv2s_service-manual_501366017.webp)
Si041251EC
Fan Motor
Removal Procedure
15
8. Fan Motor
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1
Release the fan motor
lead wires from the
hooks.
2
Remove the screw of
the fan rotor.
3
4
Remove the 2 screws
of the fan motor fixing
plate.
Unfasten the hook (a)
of the fan motor fixing
plate.
(R4389)
(R4390)
Hook (a)
(R20215)
Fan motor
fixing plate