![background image](http://html.mh-extra.com/html/daikin/atm09mv2s/atm09mv2s_service-manual_501366008.webp)
Horizontal Blades / Vertical Blade ASSYs
Si041251EC
6
Removal Procedure
2. Remove the vertical blade
ASSYs.
1
Unfasten the 3 hooks at
the shaft mounting part
by pressing them with a
flat screwdriver.
2
3
4
Unfasten the hooks at
the upper 2 positions.
Remove the vertical
blade ASSY.
Remove the other
vertical blade ASSY in
the same way.
A vertical blade ASSY has 6
fins. It is impossible to
replace only one fin.
The vertical blade ASSYs
are not marked for difference
between right and left.
Step
Procedure
Points
Hook
(R17200)
Vertical blade ASSY
(R4336)
Hook