![background image](http://html.mh-extra.com/html/daikin/atm09mv2s/atm09mv2s_service-manual_501366016.webp)
Drain Pan Unit / Swing Motor
Si041251EC
14
Removal Procedure
3. Remove the crank
assembly.
1
Remove the screw of
the crank assembly.
2
Unfasten the hook and
remove the crank
assembly.
The figure shows the
position of the hook when
the crank assembly has
been removed.
Step
Procedure
Points
Crank
assembly
(R4382)
Hook
(R4383)
Hook