![background image](http://html.mh-extra.com/html/daikin/atc25qrv16/atc25qrv16_service-manual_501360008.webp)
Horizontal Blade / Vertical Blade ASSYs
Si041402EC
6
Removal Procedure
2. Remove the vertical blade
ASSYs.
Slide the front hooks to the
right/left to unfasten easily.
1
Unfasten the 2 hooks
on the front.
2
Unfasten the 3 hooks of
the vertical blade ASSY
by pressing them with a
flat screwdriver.
3
4
Remove the vertical
blade ASSY.
Remove the other
vertical blade ASSY in
the same way.
Each vertical blade ASSY
has 6 fins. It is not possible
to replace the fins
individually.
The vertical blade ASSY is
not marked for difference
between right and left.
Step
Procedure
Points
Hook
(R20062)
Hook
(R20063)