![background image](http://html.mh-extra.com/html/daikin/atc25qrv16/atc25qrv16_service-manual_501360013.webp)
Si041402EC
PCBs
Removal Procedure
11
4. Remove the display/
signal receiver PCB.
1
2
Turn over the signal
receiver unit.
Unfasten the 3 hooks
and remove the display/
signal receiver PCB.
3
Disconnect the
connector [S27].
Some models have
[CN_MB] instead of [S27].
5. Remove the
INTELLIGENT EYE
sensor PCB.
Some models have no
INTELLIGENT EYE sensor
PCB.
1
Remove the
INTELLIGENT EYE
fixing plate.
2
Unfasten the 4 hooks
and remove the
INTELLIGENT EYE
sensor PCB.
Step
Procedure
Points
Hook
Hook
Display/signal
receiver PCB
(R23420)
Connector
(R20079)
INTELLIGENT
EYE fixing plate
(R20080)
Hook
Hook
INTELLIGENT
EYE sensor PCB
(R20081)